ANLY H5CLR, ASY-4DR Multi Function Digital Timer User Manual

June 9, 2024
ANLY

ANLY H5CLR, ASY-4DR Multi Function Digital Timer

RESTRICTIONS ON USE

When using this product in applications that require particular safety or when using this product in important facilities, please pay attention to the safety of the overall system and equipment. Install fail­safe mechanisms, perform redundancy checks and periodic inspections, and adopt other appropriate safety measures when it is necessary. This product is rated at Class II.

SAFETY PRECAUTION

This manual uses the following symbols to ensure the safe operation of this timer.

WARNING
Warnings are indicated when mishandling this product might result in death or serious injury to the user.

CAUTION
Cautions are indicated when mishandling this product might result in minor injury to the user or only physical damage to the timer.

WARNING

  • Note the incorrect wiring of this product can damage it and lead to other hazards. Make sure the product has been correctly wired before turning the power ON.
  • Before wiring, or removing/mounting the product, be sure to turn the power OFF. Failure to do so might cause an electric shock.
  • Do not touch electrically charged parts such as the power terminals. Doing so might cause an electric shock.
  • Do not disassemble the product. Doing so might cause electric shock or faulty operation.

CAUTION

  • Use the product within the operating ranges recommended in the specification (temperature, humidity, voltage, shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.
  • Firmly tighten the wires to the socket. Insufficient tightening of the wires to the socket might cause a fire.

SPECIFICATIONS

  • Operating voltage AC/DC(V): 12-48 or 100-240
  • Allowable voltage operating range 85 110% of rated operating voltage
  • Rated frequency 50/60Hz
  • Contact rating 250VAC 5A (Resistive load)
  • Reset time MAX 0.1 s
  • Life Approx. 2.5VA
  • Power consumption Mechanical: 5,000,000 times/Electrical: 100,000 times
  • Ambient temperature -10 – +50°C (without condensation & freezing)
  • Ambient humidity MAX 85%RH (without condensation)
  • Altitude MAX2000m
  • Weight Approx. 120g(H5CLR)/150g(ASY-4DR)

NAMES AND FUNCTIONS OF FACEPLATE

ANLY-H5CLR,-ASY-4DR-Multi-Function-Digital-Timer-fig-
\(1\)

SETTING PROCEDURE

ANLY-H5CLR,-ASY-4DR-Multi-Function-Digital-Timer-fig-
\(2\)

DIMENSION mm

ANLY-H5CLR,-ASY-4DR-Multi-Function-Digital-Timer-fig-
\(3\)

CONNECTION

ANLY-H5CLR,-ASY-4DR-Multi-Function-Digital-Timer-fig-
\(4\)

TIMING CHART Output mode

ANLY-H5CLR,-ASY-4DR-Multi-Function-Digital-Timer-fig-
\(5\) ANLY-H5CLR,-ASY-4DR-Multi-Function-
Digital-Timer-fig- \(6\) ANLY-H5CLR,-ASY-
4DR-Multi-Function-Digital-Timer-fig- \(7\)

ANLY ELECTRONICS CO., LTD.
http://www.anly.com.tw.

Printed in Taiwan.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals