NOTIFIER AFAWS Series Emergency Telephone Stations and Telephone Accessories User Manual
- June 9, 2024
- NOTIFIER
Table of Contents
AFAWS Series
Emergency Telephone Stations
and Telephone Accessories
User Manual
6135cov.jpg
Voice Control Systems
General
These Emergency Telephone Stations provide a reliable means of communication
for firefighters and other personnel.
Features
- Heavy-duty construction.
- Keylock or thumb-latch.
- Push-to-talk switch on telephone handset.
- Doors fit either recessed or surface enclosures.
- Red baked-enamel finish.
- Armored cable or standard telephone coiled cord.
- Available with or without a “break-glass” door feature.
- Master station connection LED indicator.
Applications
Stations feature a locked door design, with either a break lass or non-break-
glass feature. When a locked door is not required, an optional thumb catch
allows for fast, safe entry into the housing.
The telephone handsets are available with either standard coiled cord or a
durable security-type armored cable.
The hook configuration consists of two Form-C switches which permits a variety
of wiring uses. The handset rests on a handsome chrome cradle which actuates
the switch mechanism.
Installation
Either recessed or surface enclosures may be used with these Emergency
Telephone Stations. If a recessed enclosure is used, the telephone assembly
must be a model designed for recessed enclosures. The same is true of surface
enclosures.
Agency Listings and Approvals
In some cases, certain modules or applications may not be listed by certain
approval agencies, or listing may be in process. Consult factory for latest
listing status.
- UL: S635
- ULC: CS118/CS733
- CSFM: 7300-0028:0193
- MEA: 82-98-E (AFAWS-TELA)
- City of Chicago approved: Class 1, Class 2
- City of Denver approved
![NOTIFIER AFAWS Series Emergency Telephone Stations and Telephone Accessories
- models with Keylock](https://manuals.plus/wp-content/uploads/2023/03 /NOTIFIER-AFAWS-Series-Emergency-Telephone-Stations-and-Telephone-Accessories- models-with-Keylock.png)
Solid doors on surface-mount models with Keylock (left) and Latch (Right) closures.
AFAWS Product Line Information
The front door, backbox, and telephone assembly for AFAWS Series telephone
stations must be ordered separately.
HANDSET AND HOOKSWITCH ASSEMBLIES
AFAWS-TELC: Telephone with Coiled Cord Assembly
AFAWS-TELA: Telephone, Armored Cord Assembly
TELEPHONE STATION ENCLOSURES
AFAWS-BX: Backbox 15” (381.0mm)H x 8-3/8” (212.85mm)W x 3-3/8” (85.73mm)D
AFAWS-LS: Latch Door for Surface-Mount 15-3/16’ (385.60mm)H x 8-9/16”
(217.45mm)W
AFAWS-LR: Latch Door for Recessed-Mount 16-3/16” (411.00mm)H x 9-9/16”
(242.85mm)W
AFAWS-KS: Keylock Door for Surface-Mount 15-3/16’ (385.60mm)H x 8-9/16”
(217.45mm)W
AFAWS-KR: Keylock Door for Recessed-Mount 16-3/16” (411.00mm)H x 9-9/16”
(242.85mm)W
BRKG-B: Break lass Insert
Includes a tempered glass plate, a hammer attached to a chain, and a screw to
attach the hammer to the trim ring.
![NOTIFIER AFAWS Series Emergency Telephone Stations and Telephone Accessories
- Breakglass Insert](https://manuals.plus/wp-content/uploads/2023/03/NOTIFIER- AFAWS-Series-Emergency-Telephone-Stations-and-Telephone-Accessories- Breakglass-Insert.png)
PORTABLE FIREMAN’S TELEPHONE HANDSET
FHS: Fireman’s Handset.
This handset comes with a coiled cord. The attached plug fits Fireman’s Phone
Jack, model FPJ, allowing firefighters to make direct communication with a
central control area
TELEPHONE RECEPTACLES
FPJ: Fireman’s Phone Jack
Receptacle is semi-flush mounted with a single-gang box (box is not furnished
with receptacle). The receptacle has a single phone jack mounted on an
attractive, single-gang, stainless steel plate. Color-coded wires, 6 inches
long, are prewired to the jack to enable fast and accurate wiring to the
system.
EMERGENCY TELEPHONE CABINETS
FHSC-R: Storage Cabinet for 6 FHS Fireman’s handsets; recessed mounting.
FHSC-S: Storage Cabinet for 6 FHS Fireman’s handsets; surface mounted.
CABINET DIMENSIONS
Dimensions
Pictured Below| FHSC-R
Recessed Mount| FHSC-S
Surface Mount
---|---|---
Dimension “A”| 3.25″ (82.6mm)| 3.25″ (82.6mm)
Dimension “B”| 17″ (432mm)| 17″ (432mm)
Dimension “C”| 13.375 (340mm)| 13.375 (340mm)
Dimension “D”| 18.312 (465mm)| 17.312 (440mm)
Dimension “E”| 14.625 (371 mm)| 13.625 (346mm)
NOTIFIER® is a registered trademark of Honeywell International Inc.
©2010 by Honeywell International Inc. All rights reserved. Unauthorized use of
this document is strictly prohibited.
This document is not intended to be used for installation purposes.
We try to keep our product information up-to-date and accurate.
We cannot cover all specific applications or anticipate all requirements.
All specifications are subject to change without notice.
For more information, contact Notifier. Phone:
203-484-7161, FAX:
203-484-7118.
www.notifier.com
Made in the U.S. A.
firealarmresources.com
References
- Fire Alarm Resources | Download fire alarm documents
- Home (USA) | NOTIFIER by Honeywell | Engineered Fire Alarm System.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>