SIEMENS Desigo CC V4 Connect Software Gateway Instruction Manual
- June 9, 2024
- SIEMENS
Table of Contents
- SIEMENS Desigo CC V4 Connect Software Gateway
- Desigo CC Connect
- Agenda
- The Desigo CC Connect software gateway
- Main features
- Why Desigo CC Connect?
- Desigo CC family
- Desigo CC Connect Topology
- Licensing Model
- Desigo CC Connect hardware 1configuration
- Highlights of Desigo CC Connect
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SIEMENS Desigo CC V4 Connect Software Gateway
Desigo CC Connect
Target groups
- BP and RSS sales and technical personnel
Objectives
- Providing product information and positioning under Desigo CC family
- Showing key features and benefits offered by DesigoDesigo CC Connect
- Explaining use cases and topologies
Agenda
- Explaining Desigo CC Connect
- Why Desigo CC Connect
- Use cases
- Positioning under Desigo CC Family
- Licensing
The Desigo CC Connect software gateway
Connect devices of various sources
- Incorporates latest industry standards
- Integrates devices from various disciplines (e.g. fire, building automation, power etc.)
- Normalizes information into a common software layer
Edge computing at the node level
- Provides embedded interpretation and analysis capability
- Collects and analyses the integrated data directly at the node level
Elevated Data to 3rd apps
- Password protected and IT compliant for cybersecurity
- Can connect with various 3rd party applications
- Can exchange data between two or more different sources
Main features
Connectivity
- BACnet, OPC, Modbus TCP, SNMP, KNX, M M-Bus
Data Analysis
- Data collection, scripting, logics, macros, calculations
Why Desigo CC Connect?
Use Case 1: Calculation and data analysis
Sensors from different communication protocols are installed to monitor the storage area which is critical, and an expert would like to calculate the average temperature level in this area to perform KPI analysis and decide if the levels of temperature are adequate enough. Current monitoring system does not perform calculations and data analysis.
Facility expert
- Temperature sensors from system X.
- Temperature sensors from system Y.
Use Case 2: Desigo CC Connect for logical operations and data collection
The service technician is working part time in this school but would like the system to switch off the HVAC system if a fire sensor is activated. He would like also to capture the energy consumption of the building since the school owner requested energy transparency but no building management station is installed.
Service Technician
- Interactions between different disciplines, protocols and systems
- Data collection of key figures
Use Case 3: Desigo CC Connect for 3rd party applications
In a HQ of a multinational IT company various subsystems including building automation, fire safety and power, are installed. The monitoring system which is a 3rd party management station is specified with OPC connectivity for the field devices. Unfortunately, not all of the field networks and systems are communicating via OPC.
System Integrator
- Connect and normalize various communicative systems
- Deliver information to a 3rd party system via the northbound interface of Desigo CC Connect
Use Case 4: Desigo CC Connect as a replacement product for MK 8000
- Simplified streamlining of legacy software gateway, with a state-of-the-art technology powered by Desigo CC’s powerful engine.
Use Case 5: Desigo CC Connect as a replacement product for SX OPEN
- Simplified streamlining of legacy software gateway, with a state of the art technology powered by Desigo CC’s powerful engine.
Desigo CC family
Desigo CC
- Integrated building management
- Cerberus DMS
- Desigo CC Compact
- for danger management
- Desigo CC Compact
- for building automation
- Desigo CC Compact
- for electrical applications
- Desigo CC Connect
- for integration to 3rd party
Desigo CC Connect Topology
Northbound connectivity/ Southbound connectivity
Desigo CC Connect
- Supports all subsystems supported by Desigo CC powerful engine
- Desigo CC Connect can be deployed in Embedded Hardware
- Supports all south south-and northbound interfaces & APIs
- Supports system interactions, logics and scripting
- Supports trend data collection and time functions
- No clients are provided (flex, mobile, e.t.c)
- No remote notifications are provided (SMS, e-e-mails, etc.)
Desigo CC main features
- Support of latest IT standards
- Password protection
- Ethernet driver support for a variety of protocols/disciplines
- Data collection
- Calculations and reactions
- Backup functionality
- Time functions
- Exposing of data via northbound Interface(s)
- Deployable on standard or embedded hardware
- Expandable
Licensing Model
Dedicated SSNs provide the most competitive price
- Can be purchased multiple times in the same customer project to add additional 1,000 points
- Included 1000 points for any discipline (TBS Points)
- Logics and functions
- All southbound and northbound interfaces
- All available subsystem integrations
Desigo CC Connect hardware 1configuration
- Hardware is not included
Demanding configurations
Majority of applications are covered with embedded hardware
Application Examples
Simatic
- IPC227E
Dell
- BOX PC 3000
Advantech
- ARK-1123H1123H-3S51
Highlights of Desigo CC Connect
- Connect and analyze building data
- Connect to 3rd party applications
- Migration and replacement
Unrestricted © Siemens 2020
References
- Fire Alarm Resources | Download fire alarm documents
- Desigo CC - Building management systems - Global
Read User Manual Online (PDF format)