ENERGY TK02 Electronic Thermostat for Warm Floor User Manual
- June 9, 2024
- Energy
Table of Contents
ELECTRONIC THERMOSTAT ENERGY
USER-MANUAL
Dear customer!
Thank you for choosing our product!
Electronic thermostat Energy has passed through many tests to meet the
requirements of high quality product.
We hope it will legitimate your expectations and will be effective while
using.
CAUTION! Please, read this user-manual careful and keep it safe during
the whole operation period for this electronic thermostat.
I. TECHNICAL DATA
Sensing element floor sensor: NTC 10 kOhm
Sensor cable: 3m
Temperature measurement: from 0°C till 45°C in step 0.5°C
Temperature control range: from 5°C till 40°C in step 0.5°C
Operating temperature: 0°C – 50°C| Operation humidity: 5% – 90%
Maximum heating power: 3200W| Input voltage: 230V, 50/60Hz
Power consumption: 1 W| Terminals:1-2,5mm2 flexible conductor wire
Load: 14A| Protection: IP 21
Dimensions: 81x81x50MM| Weight: 0.1 kg
Certification: CE, EAC
II. INSTALLATION MANUAL
CAUTION! Power off the thermostat and the electronic device (e g heating cable) which will be connected and the electric source before installation and maintenance. It is highly recommended that the installation procedure is processed by trained personnel.
III. SENSOR INSTALLATION
-
Place the sensor with cable inside the corrugated pipe (diameter not less than 16mm). Bending radius of corrugated pipe not less than 5 cm (see Figure 1).
-
Plug one end of corrugated pipe via waterproof cork (to prevent the water or cement grout penetration inside); place the corrugated pipe with sensor in a hole between the nearest coils of heating cable.
It is recommended to place the end of corrugated pipe with the sensor inside as much closer as possible to the upper floor layer -
Place the second end of corrugated pipe near with the connection box for thermostat.
There is a possibility to lengthen the cable for sensor until 10 m
Figure 1
THERMOSTAT INSTALLATION
Electronic thermostat Energy is restricted to be used in indoor only.
It should be mounted on an inner wall about 1-1.5m above the floor in easy of
approach place with free air circulation (see Figure 1).
The thermostat is protected from steam condensate and could be mounted in
bathroom. It is not recommended to mount the thermostat near with the
equipment which could shed a warm (TV, refrigerator, heater) and also in a
places where it will could be exposed to direct sunshine. It is prohibited to
mount the thermostat in a places where it could be exposed of dripping or
splashing.
ELECTRICAL CONNECTION
CAUTION! Turn off the electric source before wiring.
1. Place into the wall the standard plastic wall socket and lead inside the
electrical wires of mains electricity 230V, heating cable and temperature
sensor.
The length of leads without insulation layer must be as follows:
– for wires of mains electricity and electrical wires of heating cable 6 mm.
– for wires of temperature sensor – 8mm
The ends of multicore cable used to be soldered to avoid the possibility of
short circuit.
2. Fix the electrical wires of temperature sensor in spring-loaded contacts
(see Figure 2) of blue color SENSOR (using the yellow clips).
The polarity of these wires is equal.
3. Fix the ends of electrical wires of heating cable in inner screw joint
contacts of green color Max.Load 14A.
4. Connect the outlets of screen from heating cable with the earth conductor
of three-phase electrical network using the external terminal contact (not
enter into the terminal block of thermostat)
5. Fix the electrical wires of neutral cable from main electricity in a green
screw joint contact N.
6. Fix the electrical wires of load cable from main electricity in a green
screw joint contact L.
7. Make sure that all connection are fixed enough strong and save.
Figure 2
MOUNTING
- Press on the catch on the top edge of the top housing using the screw and take away the front plastic frame (see Figure 3);
- Unscrew the two self-tapping screw (which fasten the top hosing to the bottom hosing) and take away the display block (do not take away the self-taping screws from the display block);
- Take away the middle plastic frame from the bottom housing of thermostat (do not take away the inter block insulation gasket from the housing);
- Place the bottom housing in a wall socket. Make sure that the wires are easily placed inside the wall socket to be sure that they will not be wedged between wall and thermostat. Fix the thermostat by the screws;
- Place the plastic frame over the bottom housing;
- Holding the plastic frame, place the top housing with display over the plastic frame, make sure that left and right grooving are in the correct position to the response holes of bottom housing and fix it to the bottom housing by the two self-taping screws;
- Make sure that all part of thermostats fit to each other and have no backlash;
- Place the front plastic panel over the display block, make sure that all buttons are correctly placed in the exact grooving, after that, lock the front panel on the display block by the catch on the top edge.
Figure 3
III. OPERATING MANUAL
MODEL TK02 LCD
Normal mode.
Press and hold the key for three second (see Figure 4) – the orange light
turns on, display goes to the Normal mode, on the display there will be
indicated:
- icon
- current floor temperature
- the heating cable ON or OFF status:
– if the floor temperature is lower than the set value (default set temperature value is 25°C) – the icon appears, the heating cable is ON;
– if the floor temperature is higher than the set value (default set temperature value is 25°C) – the icon disappears, the heating cable is OFF.
Caution! If the floor sensor is disconnected or damaged – the symbol appears, the icon disappears, the heating cable is OFF.
Figure 4
Temperature setting up.
- At Normal mode press – the icon and the set temperature appears (default set temperature is 25°C);
- Press to increase ( decrease) the set temperature value in step 0.5°C (press and hold the key or to fast advance the set temperature value in 4Hz).
Display returns to the Normal mode when no keys are pressed in 10 seconds, the icon disappears, the icon of the current floor temperature appears.
Thermostat operates as follows:
- If the floor temperature is lower than the set value (default set temperature value is 25°C) the icon appears, the heating cable is ON;
- If the floor temperature is lower than 0°C – the symbol LO and icon appears, the heating cable is ON;
- If the floor temperature is higher than the set value (default set temperature value is 25°C) – the icon disappears, the heating cable is OFF;
- If the floor temperature is higher than 40°C – the symbol HI appears, the icon disappears, the heating cable is OFF.
Off mode.
At Normal mode press and hold the key for three seconds will put the
thermostat in OFF mode – the LCD display is blank, the heating cable is OFF,
all keys are disabled except the .
MODEL TK03 LCD PROGRAMABLE
Normal mode.
Hold the key (see Figure 5) for 3 second -the orange light turns on, display
goes to the Normal mode, on the display will be indicated:
- the number of the day on the week (number 1-Monday, number 2-Tuesday, etc)
- time in 24-hours format
- program mode: morning day evening night override mode
- the heating cable ON or OFF status:
– if the floor temperature is lower than the set value for current program mode (default program setting see below) – the icon appears, the heating cable is ON;
– if the floor temperature is higher than the set value for current program mode – (default program setting see below) – the icon disappears, the heating cable is OFF.
Figure 5
Current floor temperature checking.
At Normal Mode press and hold the keys and the icon appears and the current
floor temperature will be indicated, herewith:
- if the floor temperature is lower than 0°C -the symbol LO appears
- if the floor temperature is higher than 40°C – the symbol HI appears
- if the floor sensor is disconnected or damaged – the symbol appears
The display will return to Normal mode after the keys and release.
Program Setting mode.
In Program Setting Mode you can return to Normal Mode any time by pressing the
key .
Display goes automatically to the Normal Mode when no key is press during the
20 seconds.
In case of microprocessor fault there is a Reset key in a hole – it reset the
thermostat a turn it to the default settings.
CAUTION! In case of main electricity net disconnection the thermostat
returns to default settings.
Time Setting mode
At Normal Mode press (by some thin non-sharp thing) the key in the hole – the
set value Minute will flash. Pressing the key will increase ( decrease) the
set value (press and hold or to fast advance the set value in 4Hz.)
- Set the value Minutes, then press the key – the value Hour will flash;
- Set the value Hour, then press – the value Day will flash;
- Set the value Day;
- Press – the display will return to Normal mode.
Program Setting Mode
Thermostat TK03 has an option of 4 program settings for the days from Monday
to Friday (1-5) and 2 program settings for the day Saturday-Sunday (6-7). For
each program it is necessary to set the start time from 00:00 to 23:50 with a
step of 10 minutes and floor temperature from 5°C to 40°C in step 0.5°C. The
minimum working time for each program is 10 minutes.
Default settings:
Day
| Icon| Program| Start Time| Set temperature
---|---|---|---|---
Monday-Friday (1-5)| | Morning| 06:00|
25°C
| Day| 08:00| 20°C
| Evening| 19:00|
25°C
| Night| 23:50| 20°C
Saturday – Sunday (6-7)| | Morning| 09:00|
25°C
| Night| 23:50|
20°C
- To change the program press the key in the hole P (by some thin non-sharp thing) for 3 seconds – enter to Program Setting mode – the start time of the first program Morning will appear and flash;
- Pressing the key will increase ( decrease) the start time of the first program in step of 10 minutes (press and hold or to fast advance the start time in 4Hz), set the necessary start time and press – the program set temperature will appear and flash;
- Pressing the key will increase ( decrease) the set temperature value of the first program in step of 0.5°C (press and hold or to fast advance the set temperature value in 4Hz), set the necessary temperature value and press – the start time of the next program will appear and flash;
- Repeat the procedures 2 to 3 to set the start time and the necessary temperature value for all the following five programs.
- After the temperature value is set for the last program the display will return to Normal mode.
Early start.
Thermostat TK03 has an additional option called Early start that operates
automatically:
the first program Morning will be started earlier (but no more than 60
minutes) based on last day’s actual performance so that the floor temperature
should be reached the set temperature at the scheduled time.
Manual Override mode.
The Manual Override mode is using to override the program set temperature
value temporary, it will be released until the next program:
- At Normal mode press and hold the key for 2 second – the set temperature value for current program displays;
- Pressing the key will increase ( decrease) the set temperature value in step 0.5°C (press and hold the key or to fast advance the temperature value in 4Hz);
- After the necessary temperature value is set, press the key – the display will go to Manual Override mode, the icon will appear.
The thermostat will work according to the manually set temperature value until
the start of next program.
To exit the Manual Override mode press and hold for 2 seconds the key –
display will return to Normal mode, the icon disappear, the thermostat resume
to the work according to the running program.
OFF mode.
At Normal mode hold the key for 3 second will put the thermostat in OFF mode –
the LCD display is blank, the heating cable is OFF, all keys are disabled,
except the key .
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>