BRIZO T75580-BL TempAssure Thermostatic Valve with Integrated 3-Function
Diverter
IMPORTANT DOCUMENTS ENCLOSED
CAUTION: To reduce the risk of injury due to hot water burns, make sure the enclosed labels are applied where specified on the label.
NOTICE TO INSTALLER: Place this label on the water heater next to the temperature adjustment knob.
WARNING:
This series of tub/shower valves does not adjust automatically for changes in
temperature at the hot water heater or inlet. If the temperature setting of
the hot water heater or inlet is changed, the setting on these valves must be
adjusted manually! Failure to re-adjust the valve may result in hot water
burns or extreme cold resulting from variations in line pressure (such as when
a dishwasher or washing machine is in use while you are taking a shower).
After installation, verify that the temperature knob on the valve is set so
that changes in line pressure or temperature do not result in uncomfortable
water temperature changes. If the temperature setting of the hot water heater
or inlet is changed after installation of the valve, the setting of the
temperature knob also must be changed! Consult the installation instruction
sheet for instructions on how to make this setting, or call us at
1-877-345-BRIZO.
Register Online
www.brizo.com/customer-support/product-registration
To reference replacement parts and access additional technical documents and product info, visit www.brizo.com
1-877-345-BRIZO (2749)
www.brizo.com/customer-support
Read all instructions prior to installation.
CAUTION
Failure to read these instructions prior to installation may result in
personal injury, property damage, or product failure. Manufacturer assumes no
responsibility for product failure due to improper installation.
You may need:
CAUTION: This system/device must be set by the installer to ensure safe,
maximum temperature. Any change in the setting may raise the discharge
temperature above the limit considered safe and may lead to hot water burns.
NOTICE TO INSTALLER: CAUTION!– As the installer of this valve, it is your
responsibility to properly INSTALL and ADJUST this valve per the instructions
given. This valve does not automatically adjust for inlet temperature changes,
therefore, someone must make the necessary temperature knob adjustments at the
time of installation and further adjustments may be necessary due to seasonal
water temperature change. YOU MUST inform the owner/user of this requirement
by following the instructions. If you or the owner/user are unsure how to
properly make these adjustments, please refer to page 5 and if still
uncertain, call us at
1-877-345-BRIZO (2749).
After installation and adjustment, you must affix your name, company name and
the date you adjusted the temperature knob to the caution label provided and
apply or attach the label to the back side of the closest cabinet door and the
warning label to the water heater. Leave this Instruction Sheet for the
owner’s/user’s reference.
WARNING: This thermostatic bath valve is designed to minimize the effects
of outlet water temperature changes due to inlet pressure and temperature
changes, commonly caused by dishwashers, washing machines, toilets and the
like. It may not provide protection from hot water burns when there is a
failure of other temperature controlling devices elsewhere in the plumbing
system, if the temperature knob is not properly set or if the hot water
temperature is changed after the settings are made or if the water inlet
changes due to seasonal changes.
WARNING: Do not install a shut-off device on either outlet of this valve.
When this type of device shuts off the water flow, it can defeat the ability
of the valve to balance the hot and cold water pressures.
Limited Warranty on Brizo® Faucets
Parts and Finish. All parts (other than electronic parts, air switch power modules, batteries, and parts not supplied by Brizo Kitchen and Bath Company) and finishes of Brizo® faucets purchased from authorized Brizo sellers are warranted to the original consumer purchaser to be free from defects in material and workmanship for as long as the original consumer purchaser owns the home in which the faucet was first installed. For commercial purchasers, (a) the warranty period is ten (10) years for multi- family residential applications and (b) five (5) years for all other commercial uses, in each case from the date of purchase. For purposes of this warranty, the term “multi-family residential application” refers to the purchase of the faucet from an authorized Brizo seller by a purchaser who owns but does not live in the residential dwelling in which the faucet is initially installed, such as in a rented or leased single unit or multi-unit detached home (duplex or townhome), or a condominium, apartment building or community living center. The following installations are not considered multi-family residential applications, are excluded from the 10-year warranty, and are subject to the 5-year warranty: industrial, institutional or other business premises, such as a dormitory, hospitality premises (hotel, motel, or extended stay location), airport, educational facility, long- or short-term healthcare facility (hospital, rehabilitation center, nursing, assisted or staged-care living unit), public space or common area.
Electronic Parts and Batteries (if applicable). Electronic parts (other
than air switch power modules and batteries), if any, in Brizo® faucets
purchased from authorized Brizo sellers are warranted to the original con-
sumer purchaser to be free from defects in material and workmanship for five
(5) years from the date of purchase or, for commercial users, for one (1) year
from the date of purchase. No warranty is provided on batteries.
Air Switch Power Module. The electronic power module of Brizo® air switches
purchased from authorized Brizo sellers is warranted to the original consumer
purchaser to be free from defects in material and workmanship for two (2)
years from the date of purchase or, for commercial users, for one (1) year
from the date of purchase.
What We Will Do. Brizo Kitchen & Bath Company will repair or replace,
free of charge, during the applicable warranty period (as described above),
any part or finish that proves defective in material and/or workmanship under
normal installation, use, and service. Brizo Kitchen & Bath Company may, in
its sole discretion, use new, refurbished or recertified parts or products for
such repair or replacement. If repair or replacement is not practical, Brizo
Kitchen & Bath Company may elect to refund the purchase price in exchange for
the return of the product. These are your exclusive remedies.
What Is Not Covered. Because Brizo Kitchen and Bath Company is unable to
control the quality of Brizo products sold by unauthorized sell-ers, unless
otherwise prohibited by law, this warranty does not cover Brizo products
purchased from unauthorized sellers (visit Brizo.com to see a list of our
Authorized Online Resellers).
Any labor charges incurred by the purchaser to repair, replace, install or
remove this product are not covered by this warranty. Brizo Kitchen & Bath
Company shall not be liable for any damage to the product resulting from
reasonable wear and tear, outdoor use, misuse (including use of the product
for an unintended application), freezing water, abuse, neglect, or improper or
incorrectly performed assembly, installation, maintenance or repair, including
failure to follow the applicable care and cleaning instruc-tions. Customized
components purchased by the consumer or commercial user and installed into a
Brizo product, and any damage resulting from removal or improper installation
of such components, are not covered by this warranty.
Brizo Kitchen & Bath Company recommends using a professional plumber for all
installation and repair of faucets. We also recommend that you use only
genuine Brizo® replacement parts.
What You Must Do To Obtain Warranty Service or Replacement Parts. A warranty
claim may be made and replacement parts may be obtained by calling
1-877-345-BRIZO (2749) or by contacting us by mail or online as follows
(please include your model number and date of purchase):
In the United States and Mexico:
Brizo Kitchen & Bath Company
55 E. 111th Street
Indianapolis, IN 46280
Attention: Warranty Service
https://www.brizo.com/customer-support/contact-us
In Canada:
Masco Canada Limited, Plumbing Group
Technical Service Centre
350 South Edgeware Road
St. Thomas, Ontario, Canada N5P 4L1
https://www.brizo.com/customer-support/contact-us
Proof of purchase (original sales receipt) from the original purchaser must be made available to Brizo Kitchen & Bath Company for all warranty claims unless the purchaser has registered the product with Brizo Kitchen & Bath Company. This warranty applies only to Brizo® faucets installed in the United States of America, Canada, and Mexico.
Limitation on Duration of Implied Warranties. Please note that some
states/provinces (including Quebec) do not allow limitations on how long an
implied warranty lasts, so the below limitations may not apply to you. TO THE
MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, ANY IMPLIED WARRANTY, INCLUDING
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR A PARTICULAR
PURPOSE, IS LIMITED TO THE STATUTORY PERIOD OR THE DURATION OF THIS WARRANTY,
WHICHEVER IS SHORTER.
Limitation of Special, Incidental or Consequential Damages. Please note that
some states/provinces (including Quebec) do not allow the exclusion or
limitation of special, incidental, or consequential damages, so the below
limitations and exclusions may not apply to you. TO THE MAXIMUM EXTENT
PERMITTED BY APPLICABLE LAW, THIS WARRANTY DOES NOT COVER, AND BRIZO KITCHEN &
BATH COMPANY SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES (INCLUDING LABOR CHARGES TO REPAIR, REPLACE, INSTALL OR REMOVE THIS
PRODUCT), WHETHER ARISING OUT OF BREACH OF ANY EXPRESS OR IMPLIED WARRANTY,
BREACH OF CONTRACT, TORT, OR OTHERWISE. BRIZO KITCHEN & BATH COMPANY SHALL NOT
BE LIABLE FOR ANY DAMAGE TO THE FAUCET RESULTING FROM REASONABLE WEAR AND
TEAR, OUTDOOR USE, MISUSE (INCLUDING USE OF THE PRODUCT FOR AN UNINTENDED
APPLICATION, FREEZING WATER, ABUSE, NEGLECT OR IMPROPER OR INCORRECTLY
PERFORMED AS-SEMBLY, INSTALLATION, MAINTENANCE OR REPAIR, INCLUDING FAILURE TO
FOLLOW THE APPLICABLE INSTALLATION, CARE AND CLEANING INSTRUCTIONS. Notice to
residents of the State of New Jersey: The provisions of this warranty,
including its limitations, are intended to apply to the fullest extent
permitted by the laws of the State of New Jersey.
Additional Rights. This warranty gives you specific legal rights, and you
may also have other rights which vary from state/province to state/province.
This is Brizo Kitchen & Bath Company’s exclusive written warranty, and the
warranty is not transferable.
If you have any questions or concerns regarding our warranty, please contact
us as provided above or visit our website at
www.brizo.com.
Cartridge Installation
Turn off water supplies. Remove cover (1), bonnet nuts (2) and test caps (3) from the rough-in body (4) R75000. Place a bucket or small container over the front of the valve body and slowly open the water supplies to flush any debris from the supply lines before installing the cartridge. Turn the water supplies back off.
Rotate the valve cartridge (1) so the word “UP” (2) appears on the top. The “H” is on the hot side and the “C” is on the cold side. Add silicone lube to the three o-rings (3) shown above to make the cartridge easier to install and remove from the valve body. Insert cartridge into valve body as shown. Ensure the keys on the body are fully engaged with the slots in the body (4). A light coating of plumbers grease applied to o-rings may aid in assembly.
Back to back Installation
For the exceptions of back to back or reverse installations (hot on right and cold on left) only: Rotate valve cartridge (1) so “H” is on the hot side and “C” is on the cold side and the word “UP” (2) appears on the bottom. Apply silicone lube to the three o-rings shown above to make the cartridge easier to install and remove from the rough-in body. Install the cartridge making sure that the keys are fully engaged with the slot in the rough-in body (see step B). Slide o-ring (3) and bonnet nut (4) over the cartridge and thread onto the rough-in body. Hand tighten securely. Thread bonnet nut (2) onto cartridge. Hand tighten securely. Slide o-ring (1) over the cartridge and bonnet.
Diverter Cartridge Installation
FOR DIVERTER CARTRIDGE INSTALLATION: Apply silicone lube to the o-ring
(2) to make the diverter sleeve (3) easier to install diverter cartridge.
Rotate the diverter cartridge (1) so the pin is at the bottom for proper
installation.
Apply silicone lube to the o-rings (4) to make the diverter sleeve (3) easier
to install diverter cartridge.
Align diverter sleeve so that the notches are in the same position as the
notches on rough-in body (5).
Slip-On Installation
Slide bonnet nut (6) over diverter sleeve (3) and thread into rough-in body.
Hand tighten securely.
Trim Installation
Trim Sleeve Installation
Slide trim sleeve (1) over cartridge, bonnet (2), and O-ring. Ensure sleeve is
properly positioned over the cartridge with set screw access hole downward.
O-ring will help keep trim sleeve securely in position.
Escutcheon Installation
Secure backplate (3) to rough-in body (4) using 4 screws (5) provided. Note:
Be sure backplate is oriented front side forward and markings are visible. If
mounting to an uneven surface, apply appropriate sealant around the backplate
to supplement rubber seal. Align holes in escutcheon (6) with cartridges and
slide escutcheon (6) onto backplate. Slide sleeve (7) onto escutcheon (6) and
secure by threading trim nut (8) onto diverter sleeve. Do not overtighten.
Slide diverter base (9) over trim nut (8). For thick wall installation, an
optional extension kit is available to accommodate up to 1″ of additional wall
thickness. Order RP100669.
Volume Handle Installation
Slide volume control handle (10) over cartridge, aligning flat surfaces inside
handle with flat surfaces on sides of cartridge. Handle lever should point
downward (6 o’clock) in the off position. Secure handle with set screw (11).
Note: Set screw should be started in handle before installing onto cartridge.
Then tighten set screw by placing Allen wrench through access hole in trim
sleeve.
Installation and Adjustment of the Temperature Handle. Failure to do so may cause injury. Please complete the following steps carefully.
Adjust temperature limit stop
Turn on water supplies; LET WATER RUN AT FULL HOT TO ENSURE WATER IS AS HOT AS
POSSIBLE. Place a thermometer in a plastic tumbler and hold tumbler in water
stream. Aligning the splines, place temperature handle (1) onto end of
cartridge stem (2). Rotate handle until desired maximum temperature is
achieved (not more than 120° or lower, as mandated by local plumbing code).
Remove temperature handle (1). Replace handle onto cartridge stem with handle limit stop (4) against volume handle limit stop (3), as shown. Secure temperature handle (1) onto valve stem with screw (5). Ensure O-ring (6) is assembled on handle cap (7). Install handle cap by pressing it into place on top of the temperature handle (1). Secure cap by tightening screw (8) from the underside of the handle.
Valve Trim Installation
Diverter Handle Installation
Slide diverter handle (1) onto diverter sleeve (2). Using an allen wrench,
insert set screw (3) into handle (1). Applying pressure, insert set screw
cover (4) until properly seated.
Potential scald or thermal shock injury could result due to cross flow if outlet at the shower is blocked or restricted (e.g., pause control on showerhead). Be sure to point showerhead away from you when re-starting flow or install inlet check valves on both supply lines to prevent possible injury.
Maintenance
Cannot receive more than a trickle of water: Both hot and cold supply lines
must be pressurized. If only one side is pressurized, the system will not
allow adequate flow of water.
Faucet leaks from showerhead: Remove the showerhead then turn the water on and
off to verify if the cartridge is leaking or the showerhead is draining slowly
(the showerhead may need to be cleaned if water drains slowly).
If leak persists -SHUT OFF WATER SUPPLIES Replace cartridge assembly –
RP47201.
Unable to set or maintain mixed water temperature:
SHUT OFF WATER SUPPLIES. Remove handle assembly, trim sleeve, and bonnet nut.
Check to make sure the “H” marking on the cartridge aligns with the hot inlet
and the “C” marking on the cartridge aligns with the cold inlet to the valve
body The thermostatic cartridge cannot function if hot and cold inlets are
reversed.
Low flow:
Low flow may be caused by clogged screens within the thermostatic cartridge.
To clean the hot and cold screens in the cartridge, follow the steps below:
- SHUT OFF WATER SUPPLIES.
- Remove the handle assembly.
- Unscrew the hex shaped portion of the cartridge from the brass section of the cartridge. the brass section must be held securely by the flats while the hex is rotated counter-clockwise. Failure to secure the brass section while rotating the hex can result in damage to the cartridge.
- Carefully clean any debris from the screens under running water. If the debris is difficult to remove then soak the screens overnight in a 50% water and 50% vinegar solution.
- Reassemble the cartridge.
- Replace the handle.
- Turn the water back on.
- Reset the limit stop before using the valve.
Cleaning and Care
Care should be given to the cleaning of this product. Although its finish is extremely durable, it can be damaged by harsh abrasives or polish.
To clean, simply wipe gently with a damp cloth and blot dry with a soft towel.
Diverter Handle Reference Sheet
Water Flow For 3 Function Diverter
* Shared positions do not exist in non-shared cartridges.
Water Flow For 6 Function Diverter
** Shared positions do not exist in non-shared cartridges.
Brizo Kitchen & Bath Company Product Service
55 E. 111th Street Indianapolis, IN 46280
References
- Brizo.com
- brizo.com
- brizo.com/customer-support
- brizo.com/customer-support/product-registration
- brizo.com/customer-support/contact-us
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>