RIDGID K-1500SP Drain Cleaning Machine

Safety Symbols

In this operator’s manual and on the product, safety symbols and signal words are used to communicate important safety information. This section is provided to improve understanding of these signal words and symbols.

  • This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
  • DANGER indicates a hazardous situation that, if not avoided, will result in death or serious injury.
  • WARNING indicates a hazardous situation that, if not avoided, could result in death or serious injury.
  • CAUTION indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
  • NOTICE indicates information that relates to the protection of property.
  • This symbol means read the operator’s manual carefully before using the equipment. The operator’s manual contains important information on the safe and proper operation of the equipment.
  • This symbol means always wear safety glasses with side shields or goggles when handling or using this equipment to reduce the risk of eye injury.
  • This symbol indicates the risk of hands, fingers or other body parts being caught, wrapped or crushed in the drain cleaning cable.
  • This symbol indicates the risk of electrical shock.
  • This symbol means always wear RIDGID drain cleaning mitts while operating drain cleaner.
  • This symbol indicates the risk of entanglement in a belt and pulley.

General Power Tool Safety Warnings

WARNING
Read all safety warnings, instructions, illustrations and specifications provided with this power tool. Failure to follow all instructions listed below may result in electric shock, fire, and/or serious injury.

SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE!
The term “power tool” in the warnings refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool.

Work Area Safety

  • Keep work area clean and well lit. Cluttered or dark areas invite accidents.
  • Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Power tools create sparks that may ignite the dust or fumes.
  • Keep children and bystanders away while operating a power tool. Distractions can cause you to lose control.

Electrical Safety

  • Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching outlets will reduce risk of electric shock.
  • Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electrical shock if your body is earthed or grounded.
  • Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electrical shock.
  • Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock.
  • When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
  • If operating a power tool in a damp location is unavoidable, use a ground fault circuit interrupter (GFCI) protected supply. Use of a GFCI reduces the risk of electric shock.

Personal Safety

  • Stay alert, watch what you are doing and use common sense when operating a power tool. Do not use a power tool while you are tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating power tools may result in serious personal injury.
  • Use personal protective equipment. Always wear eye protection. Protective equipment such as dust mask, non-skid safety shoes, hard hat, or hearing protection used for appropriate conditions will reduce personal injuries.
  • Prevent unintentional starting. Ensure the switch is in the OFF position before connecting to power source and/or battery pack, picking up or carrying the tool. Carrying power tools with your finger on the switch or energizing power tools that have the switch ON invites accidents.
  • Remove any adjusting key or wrench before turning the power tool ON. A wrench or a key left attached to a rotating part of the power tool may result in personal injury.
  • Do not overreach. Keep proper footing and balance at all times. This enables better control of the power tool in unexpected situations.
  • Dress properly. Do not wear loose clothing or jewelry. Keep your hair, and clothing away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts.
  • If devices are provided for the connection of dust extraction and collection facilities, ensure these are connected and properly used. Use of dust collection can reduce dust-related hazards.
  • Do not let familiarity gained from frequent use of tools allow you to become complacent and ignore tool safety principles. A careless action can cause severe injury within a fraction of a second.

Power Tool Use and Care

  • Do not force power tool. Use the correct power tool for your application. The correct power tool will do the job better and safer at the rate for which it is designed.
  • Do not use power tool if the switch does not turn it ON and OFF. Any power tool that cannot be controlled with the switch is dangerous and must be repaired.
  • Disconnect the plug from the power source and/or the battery pack from the power tool before making any adjustments, changing accessories, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool accidentally.
  • Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the tool. Power tools are dangerous in the hands of untrained users.
  • Maintain power tools and accessories. Check for misalignment or binding of moving parts, breakage of parts and any other condition that may affect the power tool’s operation. If damaged, have the power tool repaired before use. Many accidents are caused by poorly maintained power tools.
  • Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control.
  • Use the power tool, accessories and tool bits etc. in accordance with these instructions, taking into account the working conditions and the work to be performed. The use of the power tool for operations different from those intended could result in a hazardous situation.
  • Keep handles and grasping surfaces dry, clean and free from oil and grease. Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in unexpected situations.

Service
Have your power tool serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained.

Specific Safety Information

WARNING

  • This section contains important safety information that is specific to this tool.
  • Read these precautions carefully before using the K-1500 Drain Cleaners to reduce the risk of electrical shock or another serious injury.

SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE!
Keep this manual with machine for use by the operator.

Drain Cleaner Safety

  • Before using the tool, test the ground fault circuit interrupter (GFCI) provided with the power supply cord to insure it is operating correctly. A properly operating GFCI reduces the risk of electrical shock.
  • Only use extension cords that are protected by a GFCI. The GFCI on the machine power cord will not prevent electrical shock from extension cords.
  • Only grasp the rotating cable with gloves recommended by the manufacturer. Latex or loose fitting gloves or rags can become wrapped around the cable and may result in serious personal injury.
  • Do not allow the cutter to stop turning while the cable is turning. This can overstress the cable and may cause twisting, kinking or breaking of the cable and may result in serious personal injury.
  • One person must control both the cable and switch. If the cutter stops rotating, the operator must be able to tum the tool OFF to prevent the cable from twisting, kinking and breaking.
  • Use latex or rubber gloves inside the gloves recommended by the manufacturer, goggles, face shields, protective clothing, and a respirator when chemicals, bacteria or other toxic or infectious substances are suspected to be in a drain line. Drains may contain chemicals, bacteria and other substances that may cause burns, be toxic or infectious or may result in another serious personal injury.
  • Practice good hygiene. Do not eat or smoke while handling or operating the tool. After handling or operating drain cleaning equipment, use hot, soapy water to wash hands and other body parts exposed to drain contents. This will help reduce the risk of health hazards due to exposure to toxic or infectious material.
  • Only use the drain cleaner for the recommended drain sizes. Using the wrong size drain cleaner can lead to twisting, kinking or breaking of the cable and may result in personal injury.
  • Always use the rear guide hose while operating the tool and ensure the cable does not extend beyond the rear guide hose. This prevents the cable from whipping which may result in entanglement and personal injury.
  • Keep a mitt-covered hand on the cable whenever the machine is running. This provides better control of the cable and helps prevent twisting, kinking and breaking of the cable and may result in serious personal injury.
  • Position machine cable outlet within 2′ (0.6 m) of the drain inlet or properly support exposed cable when the distance exceeds 2′ (0.6 m). Greater distances can cause control problems leading to twisting, kinking or breaking of the cable. Twisting, kinking or breaking cable may cause striking or crushing injuries.
  • One person must control both the cable and the clutch. Do not lock clutch handle during operation. If the cutter stops rotating, the operator must be able to release the clutch to prevent twisting, kinking and breaking of the cable and reduce the risk of injury.
  • Do not operate the machine in REV (reverse) rotation except as described in this manual. Operating in reverse can result in cable damage and is used to back the cable end out of blockages.
  • Do not wear loose clothing or jewelry. Keep your hair and clothing away from moving parts. Loose clothing, jewelry or hair can be caught in moving parts.
  • Do not operate this machine if operator or machine is standing in water. Operating a machine while in water increases the risk of electrical shock.
  • Do not engage the drain cleaner clutch (rotate cable) while any part of the cable is in the cable carrier. This may cause striking or crushing injuries.
  • Operate the machine from the side with the FOR/OFF/REV Switch. Allows for better control of the machine.
  • Never operate the machine with the belt guard removed. Fingers can be caught between the belt and pulley.
  • Do not use if there is the risk of contact with other utilities (such as natural gas or electric) during operation. Visual inspection of the drain with a camera is a good practice. Crossbores, improperly placed utilities, and damaged drains could allow the cutter to contact and damage the utility. This could cause electrical shock, gas leaks, fire, explosion or other serious damage or injury.
  • Read and understand these instructions and the instructions and warnings for all equipment and materials being used before operating this tool to reduce the risk of serious personal injury.

RIDGID® Contact Information
If you have any questions concerning this RIDGID® product:

  • Contact your local RIDGID® distributor.

Description, Specifications, and Standard Equipment

Description
The RIDGIO- K-1500A/B & K-1500SP Drain Cleaning Machines are for cleaning 2″ through 1 O” lines. These machines are driven by induction motors that haw a grounded electrical system. An integral Ground Fault Interrupter (GFCO is built mo 1he line cord. A toggle or rotary SVf’ilI:t1 provides FORWARD/OFF/REVERSE control of the motor.

Machines are designed to use sectional-type cable that has a quick coupling system for disconnecting tools. The cable Is manually feel In and out of the machine and rotate at a cable speed of 600 to 700 RPM. The rotation of the cable Is controlled by a clutch handle. The cable stops Instantly when the clutch handle Is released.

K-1500 machines come equipped to run 1 ¼” cable to clean 3″ -10″ lines through 200′ – the 1500SP through 300′. They can be easily adapted to use 7/8″ cable to clean 2″ – 4″ lines.

Specifications
  • Lina Capacity …………… Depends on the choice of cable. Refer to the following chart for recommendations.

Motor K-1500AIB

  • Type ………………………. 115V/60Hz, Reversible, 230V- 240V/50Hz Versions Available Upon Request
  • Rating …………………….. ¾ HP
  • Amps ……………………… 10.4

K-1 SOOAIB-SP

  • Type ………………………. 115V/240V/50-60Hz, Reversible, Total Enclosed Fan Cooled
  • Rating …………………….. 1 HP
  • Amps ……………………… 15
  • Sound Pressure (LPA)* ….. .68.4 dB(A), K=3
  • Sound Power (l.wA)* …….77 dB(A), K=3

Sound measuremen1s era meaaured In accordance wflh a lllandanllzsd 18&t per Standard EN 62841· 1

K-1500A/B-SP

  • Style ……………………. 2 Wheels In Rear w/Upright Handle On Frame Assembly and Cable Storage Capacity
  • Style ……………………. 2 Wheels In Front On FrameAssembly.

See the RIDGID Catalog for machine model options and accessories. Every machine model includes as standard equipment:

Standard Equipment

  • A-1 Operator’s Mitt
  • A-12 Pin Key
  • A-34-12 Rear Guide HoseRIDGID-K-1500SP-Drain-Cleaning-Machine-fig- \(1\)

RIDGID-K-1500SP-Drain-Cleaning-Machine-fig- \(2\)

Machine Inspection

WARNING
To prevent serious injury, inspect your Drain Cleaning Machine. The following inspection procedures should be performed before each use.

  1. Make sure the Drain Cleaning Machine is unplugged and the directional switch is set to the OFF position (Figures 1 and 2).
  2. Inspect the power cord, Ground Fault Circuit Interrupter (GFCI) and plug for damage. If the plug has been modified, is missing the grounding prong or if the cord is damaged, do not use the Drain Cleaning Machine until the cord has been replaced.
  3. Inspect the Drain Cleaning Machine for any broken, missing, misaligned, or binding parts as well as any other conditions which may affect the safe and normal operation of the machine. If any of these conditions are present, do not use the Drain Cleaning Machine until any problem has been repaired.
  4. Lubricate the Drain Cleaning Machine, if necessary, according to the Maintenance Instructions.
  5. Use teals and accessories that are designed for your drain cleaner and meet the needs of your application. The correct tools and accessortes allow you ID to do the Job successfully and safely. Accessories suitable for use with other equipment may be hazardous when used with this drain cleaner.
  6. Clean any oil, grease or dirt from all equipment handles and controls. This reduces the risk of injury due to a tool or control slipping from your grip.
  7. Inspect the cutting edges of your tools. If necessary, have them sharpened or replaced prior to using the Drain Cleaning Machine. Dull or damaged cutting tools can lead to binding and cable breakage.
  8. Inspect cables and couplings for wear and damage. Cables should be replaced when they become severely wom or corroded. A worn cable can be identified when the outside coils become flat.

Warning: Worn or damaged cables can break causing serious injury.

Machine Set-Up

WARNING
Do not place the machine in water. Water entering the motor can result in electrical shock. To prevent serious injury, proper set-up of the machine and work area is required. The following procedures should be followed to set up the machine:

  1. Check work area for:

    • Adequate lighting
    • Grounded electrical outlet
    • A clear path to the electrical outlet that does not contain any sources of heat or oil, sharp edges or moving parts that may damage the electrical cord.
    • An ory place for machine and operator. Do not use the machine while standing in water.
    • Flammable liquids, vapors or dust that may ignite.
  2. Position the Drain Cleaning Machine within 2′ of the sewer inlet. The greater distance can result in cable twisting or kinking.

  3. Make sure FOR/OFF/REV switch is in the OFF position.

  4. Attach the rear guide hose by sliding the guide hose adapter onto the guide hose pins (Figure 3).
    Warning: Do not use the machine without the rear guide hose attached. Prevents cable whipping and possible entanglement and a cleaner job site.

  5. Insert the first cable into the front of the machine (female end first) and push through the guide hose until approximately one foot remains out the front of the machine (Figure 4).
    Never couple more than one cable at a time. The cable will extend behind the rear guide tube.

  6. Select and install the proper tool to the end of the cable. The T-51ot Coupler alk: Ms the tool to be snapped into the cable coupler (Figure 5). To remove the tool, use the pin key to depress the plunger and slide the coupling apart.
    NOTE! Proper Tool Selection
    A good rule of thumb is to use a tool at least 1″ smaller than the line to be cleaned. The style of the tool is determined by the nature of the job and is left up to the operator.

  7. Plug the Drain Cleaning Machine into the electrical outlet, making sure to position the power cord along the clear path selected earlier. If the power cord does not reach the outlet, use an extension cord in good condition.

Warning:
To avoid electric shock and electrical fires, never use an extension cord that is damaged or does not meet the following requirements:

  • The cord has a three-prong plug similar to the description in the Electrical Safety section.
  • The cord is rated as W or “W-A~ if being used outdoors.
  • The cord has sufficient wire thickness (14 AWG – 50′). If the wire thickness is too small, the cord may overheat,, melting the cord’s insulation or causing nearby objects to ignite.

Warning:
To reduce the risk of electrical shock, keep all electrical connections dry and off the ground. Do not touch the plug with wet hands. Test the Ground Fault Circuit Interrupter (GFCI) is provided with the electric cord to insure it is operating correctly. When the test button is pushed in, the indicator light should go OFF. Reactivate by pushing the reset button in. If the indicator light goes ON, the machine is ready to use. If the GFCI does not function correctly, do not use the machine.

Operating Instructions

WARNING
Wear mitts with rivets provided with the machine. Never grasp a rotating cable with a rag or loose-fitting cloth that may become wrapped around the cable causing serious injury. Always wear eye protection to protect your eyes against dirt and other foreign objects. Wear rubber-soled, non-slip shoes.

Be very careful when cleaning drains where cleaning compounds have been used. ear gloves when handling cable and avoid direct contact with the skin and especially the eyes and facial area as see serious burns can result. Do not operate with the clutch handle locked in place. The clutch is a safety feature designed to stop the rotation of the cable when released.

CAUTION
It is very important to know the approximate distance from the inlet to the main sewer or septic tank. Over-running cable too far into the main sewer or septic tank can cause cables to knot up and prevent their return through small lines. If the main is 12 inches or larger and standard 11/4• cable is being used, do not allow more than 1 o to 15 feet of overrun. When working into a septic tank do not allow more than 3 to 5 feet overrun.

  1. Assume the correct operating posture in order to maintain proper balance (Figure 6).
    Warning: Should an unexpected situation arise, this posture provides you with the opportunity to safely keep control of the machine end cable.

    • Ba sure you can quickly release the clutch handle.
    • Hand must be on the cable to control its twisting action when it hits an obstruction.
    • Must have access to FOR/OFF/REVERSE switch.
  2. Pull sufficient cable out of the machine to start the tool and cable into the sewer inlet. Push the cable into the inlet as far as it will go.

  3. Pull enough extra cable through the machine to find almost a half circle between the machine and the line opening.

  4. Hold cable loosely in mitted hand. Put FOR/OFF/REVERSE switch in FOR (forward) position.
    NOTE The motor will start but the cable will not rotate.

  5. With a milted hand on the cable, push down on the clutch handle with the opposite hand to engage the cable. Push down on top of the cable loop with a definite snap to advance the cable.
    NOTE A slow or gradual engaging of the clutch handle causes excessive wear of the jaw set The clutch is instant-acting and returning the clutch handle to its original position frees the cable instantly.

  6. As soon as excess cable has gone into line, release the clutch handle and pull six to ten inches of cable out of the machine with a mitted hand.

  7. Continue to feed the cable into the line until resistance or obstruction is encountered. This will become apparent to the operator as it will be difficult to feed the additional cable into the line and/or the cable will have a tendency to twist sideways in the operator’s hands.

  8. If the cable loads down in the obstruction, relieve the load by pulling back on the cable with short, quick jerks to the tree cutter. Slowly advance the cable back into the obstruction. Repeat this process until the obstruction is dear. Remember, make sure the cutter is rotating at all times, and never force the cable. At this point, progress depends upon the sharpness of the tool and the nature of the obstruction.
    WARNING
    Do not allow tension to build up in the cable. This will happen if the cutting tool hits a snag and stops turning, but the motor and cable continue to date. Torque builds until the cable suddenly twists, potentially wrapping around your hand or arm. This can happen quickly and without warning, so proceed slowly and carefully as you feed the cable into the drain. Releasing the clutch handle will stop the cable from dating and releases the torque. If the tool gets hung up in an obstruction, refer to Reverse Operating Instructions in the “Special Procedures” section.

  9. Once obstruction IS cleared, It IS recommended that operator flush debris from the line with running water. Repeat Step 8 several times if necessary for a thorough cleaning job and then work the cable through additional stoppages as required.

  10. To add cable, the following procedure should be followed:

    • After reaching the end of each cable section, turn the machine OFF.
    • Secure the cable by looping it in the line (Figure 7). This procedure is especially useful when cleaning a line with a steep grade.
    • With the line secured, insert another section of cable in through the front of the machine (female end first) until approximately one foot remains out the front of the machine.
    • Attach cable to cable in line and resume operation.
  11. To retrieve the cable from the drain line, the following procedure should be followed:

    • Leave FOR/OFF/REV switch in FOR (FORWARD) position.

    • Push down on the clutch handle to engage the cable.
      With a mitted hand pull the cable out of line (if possible) or hold the cable against the edge of the inlet to thread the cable out until loop forms in front of the machine.
      NOTE! By holding the cable against the edge of the inlet, the rotation will rapidly “thread’ the cable out of the line.

    • When loop fonts, release the clutch handle and push the excess cable back through the machine. Disconnect one section at a time.
      Warning: When disconnecting sections, remember to turn the unit OFF and secure the cable in line.

    • Once a section of cable is removed, insert the sea. ired cable in through the front of the machine and continue removing sections until the tool on the last section of cable is just inside the sewer inlet.

    • When placing removed cables back into the cable carrier, reconnect all cables. This assures easy removal at the next job.
      Warning: Never retract the tool from the sewer inlet while the cable is rotating. The tool can whip causing serious injury.

  12. Tum FOR/OFF/REV Switch to OFF position.

  13. Pull the remaining cable and tool from the sewer.

  14. Unplug the power cord and remove the guide hose.

CAUTION
After using, thoroughly flush and drain cables, couplings, and tools with water due to the damaging effects of some drain cleaning compounds.

Special Procedures

Reverse Operation
Running the machine in reverse will cause premature failure of the cable. Use reverse only to free a tool caught in an obstruction. If this should occur, immediately release the clutch handle and place FOR/OFF/REV switch in the OFF position. After the motor comes to a complete stop, place FOR/OFF/REV switch In the REV (REVERSE) direction. Engage the clutch handle only until the tool Is free of obstruction. Once the tool Is free, release the clutch handle immediately. Tum unit OFF. Run the unit In FOR (FORWARD) direction and follow normal operating procedure.

WARNING:
Never operate this machine in REV (REVERSE) for any other purpose. Operating in reverse can damage a cable and cause serious injury.

Cable Applications
Standard Cable: Standard W’ or 11/l cable can be used in straight lines from 3″ through so and through fittings. (Figu/9 8)

Heavy-Duty cable:
Where conditions allow, heavy-duty 1 ¼ inch cable, such as C-14, should be used for faster results and longer cable life. The heavy-duty cables ‘INOrk effectively in 4″ through 8″ straight lines. (Figure 9)

NOTE:
This type of cable should not be used in areas where 4″ “P” traps or 4″ running traps are currently in use.

Faster Cleaning:
Obstructions of grease or fats can be cleaned faster and more effectively by bending the cable some 6″ or 8″ behind the cutter. (Figure 10)

Storing And Transporting Cabla

(“A” Frame Models Only)
Cables can be stored and transported on “N-frame models as shown in Figure 11.RIDGID-K-1500SP-Drain-Cleaning-Machine-fig- \(12\)

Accessories

WARNING:
Only the following RIDGID products have been designed to function with the Sectional Drain Cleaning Machines. Other accessories suitable for use with other tools may become hazardous when used on the machines. To prevent serious injury, use only the recommended accessories.

K.1500A/B Machines

Cables and Laadara

Catalog

No.

| Model

No.

| ****

Description

---|---|---
92280| C-11| 15′ Standard All-Purpose Wind,”/•” Pflch.

Good for 4″ Traos, 3′ – 8′ Lines.

62285| C-12| 15′ Extra-Heavy-Duty Wind,

4″ – 10′ Lona Runs, No 4′ Tr

| :•wPIich.

aos.

62295| C-14| 15′ Heavy-Duty Wind, ‘Ii” Pitch. s·· 1O” Lines,

Through Cleanout, No 4• Traps.

62300| C-15| 15′ Extnt-Flable Wind, v • Pilch. S’ • 6′ Lines

Good for TraPS.

63090| T-27| 1 ‘/.” x 25’ Leader
62275| C-10| –

15′ Standard AII-Purpoee Wind,

Requires A-368X Jawset ‘lo” Tools

Accessories

Catalog

No.

| Model

No.

| ****

Description

---|---|---
59470| A-8| Cable carrier, 80′ capacity (1¼’)
59210| A-10| Cable Carrier, 150′ Capacity (1 ‘/;”l
59415| A-34–10| 10′ Rear Gulde Hose
59395| A-34–12| 12′ Rear Guide Hose
59400| A-34–16| 16′ Rear Guide Hose
59300| A-20| 8′ Front Guide Hose Assembly
59205| A-1| Left-Hand Mitt
59295| A·2| Right-Hand Mitt
59360| A-S| Tool Box
59225| A-12| Coupling Pin Key
59440| A-4| Trap Spoon (30″)
59240| A-17| Manhole Guide Pipe
59320| A-369X| 11/,• Replacement Jawset

Toole for c-11, c-12, C-14 and C-15 C8blas 1¼”RIDGID-K-1500SP-Drain-
Cleaning-Machine-fig- \(20\)

NOTE! See RIDGID Catalog for a complete list of tools and accessories.

Maintenance Instructions

WARNING
Make sure the machine is unplugged from the power source before performing maintenance or making any adjustments.

Moving Paris Lubrication
Grease all exposed moving parts such as rocker arms and main bearing approximately every three months. Make sure to grease the main bearing thru the grease fitting inside the clutch handle slot.

Clutch Jaws Lubrication
Clean and lubricate clutch driver jaws with oil after each use.

Cables
Cables should be thoroughly flushed with water to prevent the damaging effects of sediment and drain cleaning compounds. Periodically lubricate cables and couplings with RIDGID Cable Rust Inhibitor.

When not in use, store cables indoors to prevent deterioration by the elements. Cables should be replaced when they become severely corroded or worn. A worn cable can be identified when the outside coils of the cable become flat.

Clutch Jaws Replacement

  1. Remove four screws holding the front guard to the housing.
  2. Remove screws from the nose piece assembly (Figure 12).
  3. Slide out clutch driver jaws and replace with desired size jaws.
  4. Replace nose piece assembly, screws, and guard.

WARNING:
Never operate the machine with the belt guard removed. Fingers can be caught between the belt and the pulley.

Removing Clutch End Play

  1. To remove end play from the clutch, loosen the screw in the Adjusting Nut. (Figure 14).
  2. Turn the lock and adjust the nut clockwise until snug against the housing, then back off one-half tum.
  3. Tighten the screw in the lock and adjust the nut.

V-Belt AdJustment
Check V-Belt periodically for loosening. V-Belt should be kept tight at all times.

  1. To tighten V-Belt remove Guard.
  2. Loosen the locknut, tum adjusting the bolt slowly until VBelt stiffens, tighten locknut. (Figure 15).

Machine Storage

WARNING:
Motor-(driven equipment must be kept indoors or well covered in rainy weather. Store the machine in a locked area that is out of reach of children and people unfamiliar with drain cleaners. This machine can cause serious injury in the hands of untrained users.

If the machine has been exposed to freezing weather, the unit must be run for ten (10) to twenty (20) minutes without load to wanna up. Failing to do this will result in frozen bearings. If the machine is exposed to the weather for a period of time, moisture will form across motor windings causing the motor to bum out.

Service and Repair

WARNING
The “Maintenance Instructions” will take care of most of the service needs of this machine. Afr/ problems not addressed by this section should only be handled by an authorized RIDGID service technician.

The tool should be taken to a RIDGID Independent Authorized Service Center or returned to the factory. All repairs made by Ridge Tool service facilities are warranted against defects in material and workmanship.

WARNING:
When servicing this machine, only identical replacement parts should be used. Failure to follow these instructions may create a risk of electrical shock or another serious injury.

If you have any questions regarding the service or repair of this machine, call or write to: Ridge Tool Company

For the name and address of your nearest Independent

Wiring Diagram

K-1 SOOA/B Wiring Diagram 115VRIDGID-K-1500SP-Drain-Cleaning-Machine-fig-
\(17\)

K-1 S00SP Wiring Diagram 120v/60 HzRIDGID-K-1500SP-Drain-Cleaning-
Machine-fig- \(18\)

K.1500SP Wiring Diagram 22o-240V/50 HzRIDGID-K-1500SP-Drain-Cleaning-