Specifications

# Item Parameter
1 Nominal Output Voltage 12.8V
2 Nominal Capacity 100Ah @ 0.5C
3 Actual Capacity >100Ah @ 1C
4 Internal Resistance =20mQ
5 Charging Voltage 14.6V
6 Max Charging Voltage 14.6V
7 Discharge Cut-off Voltage 9.2V
8 Self Discharge Rate (Per Month) <3% (25°C)
9 Continuous Charge Current 50A
10 Continuous Discharge Current 100A
11 Charging Protection Temperature 0°C(+5°C)/32°F(+9°F)
12 Operating Temperature Charge Discharge
13 Storage Temperature 1Month 1 Year
14 S i z e (MM/IN) 330 x 173 x215MM /13 x 6.8 x 8.461N
15 Weight (KG / LB) 12.5KG / 27.5LB

Applications

| |
---|---|---
Motorhome| Travel Trailer| Trolling Motor
| |
Houseboat| House| Dump Trailer

Suggest charging the Power Urus battery periodically to the regular battery storage voltage (12.8V~13.24V, 30 ~ 50% SOC) to avoid over-discharge.

Wiring Diagram ( Series & Parallel )

  1. Series Connection (48V 100Ah)PowerUrus S12100 12V LiFePO4 Battery - Series
  2. Parallel Connection (12V 200Ah)PowerUrus S12100 12V LiFePO4 Battery - Parallel
  3. Series & Parallel Connection (24V 200Ah)PowerUrus S12100 12V LiFePO4 Battery - Series & Parallel

All Power Urus batteries must be separately recharged fully before being connected i n series or parallel.
If connected in both of series and parallel, make sure connect the Power Urus S12100 batteries in parallel first, then connect the parallel Power Urus S12100 batteries in series.
Power Urus S12100
For series connection, all batteries must be charged or discharged a t the same time for proper functionality.
Do not connect more than four Power Urus S12100 i n series.
**** Do not recommend connecting more than two Power Urus $12100 batteries in parallel.

Power Urus S12100
Power Urus S12100
** If connected in both of series and parallel, recommend connecting the maximum four Power Urus S12100 batteries in series and two Power Urus S12100 batteries in parallel  (Max 4S2P),.
Power Urus S12100
** Do not connect the Power Urus S12100 with the Power Urus batteries i n different models or the batteries from other manufacturers.

Attention

|  Use certified lithium battery charger or SLA battery charger to recharge.
---|---
| Do not expose t o liquids
| Do not disassemble
| Avoid dropping
| Automatically stop charging under 0°C/32°F (Low-temperature Protection)
| To maximize the life span of the battery cells , suggest using the Power Urus battery within  70%DOD,constant charge and discharge rate should not exceed 0.2C.