POTTER VSA SERIES Vault Sound Alarm System Owner’s Manual
- June 9, 2024
- POTTER
Table of Contents
POTTER VSA SERIES Vault Sound Alarm System
Introduction
- UL Listed
- Push button balancing
- On-board accumulator
- Built-in test button and sounder
- Manual sensitivity adjustment
- Powered by alarm panel
- Self-test to validate system performance
The VSA series is a self-contained sound detection system listed by
Underwriters Laboratories, Inc. for the primary protection of reverberant and
non-reverberant vaults, such as bank and mercantile vaults.
The VSA system contains a microprocessor driven DC differential balance
control which is adjusted so that the impedance of the microphone circuits are
balanced with the internal impedance of the differential circuit. The
VSA will alarm through it’s SPDT alarm relay contacts if the microphone
circuit impedance increases or decreases.
The main controller and the microphone are combined into a single enclosure
(VSA-1).
The main controller utilizes a single button for system balancing. The on-
board accumulator allows the system to alarm after receiving a set number of
pulses during a 10-minute time frame. The accumulator has an adjustable range
of 0 to 9 pulses. Sensitivity is manually adjustable to detect all attacks as
set forth in UL 639 and UL 681.
The on-board test button and sounder provide a means to manually test the
system during system inspection.
The Remote Test Annunciator (RTA) can be installed in a remote location,
likely by the alarm control panel. The RTA allows for remote testing and it
annunciates the system condition with LED’s.
The optional self-test feature validates the system’s performance. This
feature enables the user to be informed of possible system degradation, due to
severe environmental changes, before finding out too late.
The VSA will integrate and may be powered by any alarm control panel.
The VSA-2K is a kit consisting of one (1) VSA-1 Controller/Microphone, one (1)
VSM microphone, and one (1) RTA remote test annunciator.
Coverage can be expanded by adding eight (8) additional VSM microphones for a
total of ten (10) microphones, including the VSA-1 control unit/microphone.
Where UL certification is required, the VSA system must be installed in
compliance with U.L. 681. Including at least one manual-initiating device in
the vault and connection of the VSA to a UL listed control unit.
Ordering Information
Model
| Description| Stock Number
---|---|---
VSA-2K| (1) VSA-1 controller/microphone, (1) VSM microphone, (1) RTA remote
test annunciator|
2000076
VSA-1K
| (1) VSA-1 controller/microphone, (1) RTA remote test annunciator| 2000075
VSA-1| controller/microphone|
2000070
VSM
| microphone| 2000071
RTA| remote test annunciator|
2000073
VFM
| flush mount kit|
2000072
Specifications
Dimensions | ø5.12″ x 3.43″ |
---|---|
Weight | VSA-1 (1.1lb), VSM (0.9lb) |
Ambient Temerature | 32°F to 120°F (0°C to 49°C) |
Output Contacts | 1 Form C for tamper relay, 2.0 amps @ 30VDC 1 Form B for |
tamper relay, 2.0 Amps @ 30VDC
Annunciators| On-board Status LED (not visible through enclosure)
Remote Annunciator Testing| LED’s for displaying system status and test switch
for remote testing
Testing| Remote connections to a test switch initiates system test for users.
On-board test button to facilitate installation.
Accumulator| Integrated into the VSA-1 conrol unit permitting 0-9 accumulated
signals at 25% below the standard alarm threshold
Balancing| Automatic balancing by pressing a balancing button
Sensitivity| Manually adjustable to detect all attacks set forth in UL639 and
UL681 for sound detectors
Input Power| 9VDC to 16.0VDC, 12VDC nominal
Operating Current| 50mA nominal/250mA maximum (at test sound generation)
Enclosure| Halogen free high impact PC/ABS alloy based enclosures with tamper
(Do not use VSM tampers, wiring supervision is provided by VSA-1)
Electrical Connections| Two ½” conduit openings
Humidity| 85%
Typical System Layout
It is recommended to install at least one VSA-1 or VSM in every 12′ x 12′ area
Customer Support
Potter Electric Signal Company, LLC
2081 Craig Road, St. Louis, MO, 63146-4161
Phone:800-325-3936/Canada
888-882-1833
www.pottersignal.com
firealarmresources.com
Documents / Resources
|
POTTER VSA SERIES Vault Sound Alarm
System
[pdf] Owner's Manual
VSA SERIES Vault Sound Alarm System, VSA SERIES, Vault Sound Alarm System,
Sound Alarm System, Alarm System
---|---
References
- Fire Alarm Resources | Download fire alarm documents
- Potter Electric: Fire Alarms & Fire Sprinkler Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>