Features
- Tamperproof field selectable candela settings of 15, 30, 60, 75, and 110
- Lens colors available in amber, blue, green, and red
- Super-Slide® Bracket – Ease of supervision testing
- Checkmate® – Instant voltage verification
- Synchronize strobe and/or horn with AVSM module
- Silence audible while visual appliance remains flashing (for use in accepted jusridictions)
- Switch for chime, whoop, mechanical, and 2400Hz tone
- Switch for continuous or temporal 3 tone (not available on whoop)
- Tamperproof re-entrant grill
- Product includes a 5 year warranty
Application
The CS/CHS Series Colored Lens Signals are wall mount, low profile strobes and horn/strobes that offer dependable audible and visual signals for warning and emergency notification. Applications include emergency communication, severe weather, emergency response and many more.
Description
The CS/CHS Series Colored Lens Signals are 24VDC units available in lens
colors of amber, blue, green, and red. The Series offers tamperproof field
selectable options of 15, 30, 60, 75, and 110 candela.
They have a minimal operating current and a minimum flash rate of 1Hz,
regardless of input voltage. The strobes can be synced using a Gentex sync
protocol or the AVSM Sync Module.
The Colored Lens Series is shipped with a die-cast universal 4” mounting
bracket which incorporates the popular Super-Slide® feature that allows the
installer to easily pre-wire the system and test for supervision. The product
also features a locking mechanism that secures the signal to the bracket
without showing any screws. The Colored Lens Series also features the
Checkmate® – Instant Voltage Verification Feature which allows the installer
to check the voltage drop, current draw, and match against the blue print.
Product Listings
- ANSI/UL 464 and 1638
- CSFM 7135-0328:0210 (CHS Series)
- CSFM 7135-0328:0209 (CS Series)
Technical Specifications
Operating Voltage | Nominal 24VDC (16-33VDC) |
---|---|
Environmental Limitations | 32°F – 120°F (0° – 49°C) |
Indoor Only
Dimensions| 5″ H x 4.5″ W x 2.5″ D
Wiring Connections| Terminals accept 18 – 12 AWG
Mounting| Single gang, double gang, or 4″ square backbox
Surface mount with AVBB
Shipping Weight| 1.05 lbs.
CS Series Colored Lens Strobe, Selectable Candela
Model Number| Stock Number| Lens Color| Body Color
CS-24WAR| 4890100| Amber| Red
CS-24WAW| 4890101| Amber| Off-White
CS-24WBR| 4890102| Blue| Red
CS-24WBW| 4890103| Blue| Off-White
CS-24WGR| 4890104| Green| Red
CS-24WGW| 4890105| Green| Off-White
CS-24WRR| 4890106| Red| Red
CS-24WRW| 4890107| Red| Off-White
Optional Bezels
Wording| Color| Stock Number
AGENT| Red| 4890262
AGENT| Off-White| 4890263
ALERT| Red| 4890264
ALERT| Off-White| 4890265
All CS/CHS Series devices are plain (no wording).
AGENT/ALERT bezels can be ordered separately.
CHS Series Colored Lens Strobe, Selectable Candela
Model Number| Stock Number| Lens Color| Body Coor| Reverberant dBA at 10′, per
ANSI/UL 464| In Anechoic Room dBA at 10′
CHS-24AR| 4890120| Amber| Red| 62-82| 100
CHS-24AW| 4890121| Amber| Off-White| 62-82| 100
CHS-24BR| 4890122| Blue| Red| 62-82| 100
CHS-24BW| 4890123| Blue| Off-White| 62-82| 100
CHS-24GR| 4890124| Green| Red| 62-82| 100
CHS-24GW| 4890125| Green| Off-White| 62-82| 100
CHS-24RR| 4890126| Red| Red| 62-82| 100
CHS-24RW| 4890127| Red| Off-White| 62-82| 100
UL Max Strobe Current Ratings (24VDC Regulated)
Candela| Amber Lens| Blue, Gree, and Red Lens
15cd| 47mA| 105mA
30cd| 64mA| 130mA
60cd| 113mA| 203mA
75cd| 145mA| 243mA
110cd| 178mA| 310mA
For unfiltered FWR ratings, see installation manual.
Horn Decibel and Current Ratings
Horn Setting| Minimum
dBA at 10′, Per UL 464
(HIGH)| Minimum
dBA at 10′, Per UL 464
(LOW)| Regulated 24VDC
Max. Operating Current, at High Setting (mA)
Temporal 3 2400Hz| 78| 71 | 28
Temporal 3 Mechanical| 76| 70| 25
Temporal 3 Chime| 70| 66| 15
Continuous 2400Hz| 81| 74| 28
Continuous Mechanical| 80| 72| 25
Continuous Chime| 70| 66| 15
Whoop| 82| 69*| 56
*Operating the horn in this mode at this voltage will result in not meeting the minimum ANSI/UL 464 reverberant sound level required for public mode fire protection service. These settings are acceptable only for private mode fire alarm use. Use the high dBA setting for public mode application (not applicable when using the chime tone. The chime tone is always private mode).
Tone Switch Locations
Tone | Switch Position |
---|---|
3 | 4 |
Mechanical Temporal 3 | ON |
Mechanical – Continuous | OFF |
2400Hz – Temporal 3 | ON |
2400Hz – Continuous | OFF |
Chime – Temporal 3 | ON |
Chime – Continuous | OFF |
Whoop | ON |
Whoop | OFF |
NOTES:
- Switch Positions 1 and 2 in the OFF position to select isolated horn and strobe power inputs
- Switch Position 6 ON = HIGH dBA
- Switch Position 6 OFF = LOW dBA
Super Slide® Mounting Bracket
Allows the installer to pre-wire the system, test for system supervision,
remove the signal head until occupancy, switch out signals without changing
mounting brackets and has locking edge connector for snap-in-place
installation.
Checkmate® Instant Voltage Verification
It is often necessary to confirm the voltage drop along the line of devices.
The access holes are provided in the back of the terminal block to allow the
voltage to be measured directly without removing the device. Typically, this
would be done at the end of the line to confirm design criteria. Most
measurements will be taken using the S+ and S- locations although access is
provided to other locations.
NOTE: Care should be taken to not short the test probes.
To remove bezel, grip both sides of bezel and pull in a download and outward motion.
Wiring Diagrams
NOTES:
-
All strobes are designed to flash as specified with continuous applied voltage. Strobes should not be used on coded or pulsing signaling circuits.
However, use of the AVSM control module or Gentex synchronization protocol is permitted to synchronize the strobe, horn and/or mute the horn. -
FOR SYNCHRONIZATION WIRING INFORMATION, REFERENCE AVSM CONTROL MODULE DATA SHEET (8830050) AND/OR AVSM CONTROL MODULE MANUAL FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM CONTROL MODULE DATA SHEET AND MANUAL CAN BE OBTAINED AT http://pottersignal.com OR CALL POTTER ELECTRIC AT 1-800-325-3936.
Architect and Engineering Specifications
The audible and/or visible signal shall be Potter Colored Lens Series or
approved equal and shall be listed by Underwriters Laboratories Inc. per
ANSI/UL 1638 and ANSI/UL 464 and shall have compliance with the polar
dispersion requirements of ANSI/UL 1971. The notification appliance shall also
be listed with the California State Fire Marshal (CSFM).
The notification appliance (combination audible/visible) shall produce a peak
sound output of 100dBA or greater as measured in an anechoic chamber. The
signaling appliance shall also have the capability to silence the audible
signal while leaving the visible signal energized with the use of a single
pair of power wires. Additionally, the user shall be able to select either
continuous or temporal tone output with the temporal signal having the ability
to be synchronized.
Unit shall be capable of being installed so that any unauthorized attempt to
change the candela setting will result in a trouble signal at the fire alarm
control panel.
The audible/visible and visible signaling appliance shall also maintain a
minimum flash rate of 1Hz or up to 2 Hz regardless of power input voltage. The
appliance shall have an operating current of 74mA or less at 24 VDC for the
15Cd strobe circuit.
The appliance shall be polarized to allow for electrical supervision of the
system wiring. The unit shall be provided with a mounting bracket with
terminals with barriers for input/output wiring and be able to mount to a
single gang or double gang box or double workbox without the use of an adapter
plate. The unit shall have an input voltage range of 16-33 volts with either
direct current of full wave rectified power for 24 volt models.
The appliance shall be capable of testing supervision without disconnecting
wires. Also, the appliance shall be capable of mounting to a surface back box.
The unit shall also be able to verify voltage at the unit without removing
unit.
Potter Electric Signal Company, LLC • St. Louis, MO •
Tech Support: 866-956-1211 / Customer
Service: 866-572-3005
• www.pottersignal.com
ISO 9001:2008
CERTIFIED
DESIGNING, MANUFACTURING, & DISTRIBUTING QUALITY SYSTEMS
8830055 – REV B • 10/14
firealarmresources.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>