PRODUCTOVERVIEWINTERFACE AND LEDs
1.1Brief Introduction
G200 Series gateway is a portable indoor gateway and complies with LoRaWAN™
protocol to provide low power, stable and secure wireless connectivity for
devices and sensors. G200 adopts star topology deployment and provides WiFi or
Ethernet connection to a network server. The solution is used in a wide area
of applications such as smart energy, smart cities, and agricultural IoT. G200
meets the network requirements of long-range communications, strong anti-
interference ability, high sensitivity, and low power for many dispersed nodes
to provide a low-cost and high-reliability indoor IoT solution.
** 1.2 Features**
-
Low Cost
Compact and portable, easy to install, cost-effective for LoRa network deployment. -
Stable Network
The legal nodes can move freely within gateway coverage. When one gateway is abnormal in the multi-gateway network, the node can be accessed through an adjacent gateway. -
Versatile BackhaulOptions
Support Ethernet/WiFi, support switch dynamically. -
Easy Maintenance
Support remote troubleshooting and firmware upgrade, support local connection for debugging.
INTERFACE AND LEDs
2.1 Interface
Port 1: LoRaAntenna (SMA-female)
Port 2: RESET
Port 3: SIMCard Slot
Port 4: MicroUSB
Port 5:Ethernet (RJ45)
Port 6: DC12V DC_IN
Port 7: WiFi Antenna(SMA-female)
NOTE: 1, Port 2: RESET hole, head into RESET hole with one end of paper
clip for 6 seconds, then out. G200 restore factory defaults.
2.2 LED Status Indications
LEDs | Function definition |
---|---|
Flash blue and green every 1 second | • Normal data forward |
• Normal data forward
Flash red and blue every 1 second| • Abnormal NS connection
• Normal data forward
Flash red and green every 1 second| • Abnormal NS connection
• Abnormal data forward
White lights up for 1 minute| Gateway power on, system initialization
Off| Gateway is not powered on
SPECIFICATION
LoRa Parameters
Frequency Band | 915MHz |
---|---|
Communication | LoRaWAN, Star Network |
Modulation | Lora |
Mode | Half-duplex |
Sensitivity | -137dBm @SF12/13W 125KHz |
Max Transmitter Power | 17 dBm (Typical) |
Channel & Bandwidth | 125KHz/250KHz/500MHz Configurable |
Interface | EthemetANiFi |
Communication Distance | Suburban 5Krn, urban 3Km |
Physical
IP Gracia | 1P30 |
---|---|
Size | 142mm”142mm*35mm |
Color | Off white |
Material | PC+ABS |
Input Voltage | DC12V(11.0 VDC — 14.0 VDC) |
Installation | Desktop/Wall mount/Ceiling mount |
Operating Temperature | 0-60°C |
Operating Humidity | 0-90%RH |
Thermal Methods | Radiator grille |
Hardware
Prnroccnr | MIPS 65MHz |
---|---|
RA | |
Flash | 16MB |
Vivi | QCA9513 |
Security System
System Encryption | AES128 |
---|
Remote Management
Upgrade and Maintenance | Remote monitoring of network status |
---|
Support remote firmware upgrade. configuration backup and recovery
CONFIGURATION
G200 provides a friendly and easy way to configure network parameters and LoRa
parameters. After the configuration/modification is completed, you need to
click the Save & Apply button at the bottom right of the page to save. After
all the configuration/modifications are completed, you need to restart the
gateway to take effect.
4.1 Getting Started
Please follow the steps below to log in: Step 1: Search AP
ELI-G200-XXXXXX(XXXXXX is the last six hex number of G200 MAC) for G200, click
connect, password:easylin kin.
Step 2: If the connection is successful, open browser (recommend IE browser)
and input IP address: 192.168.3.1
Step 3: After entering the login page, input your username, and password. Then
enter the overview page, as shown below.
Username: admin (default)
Password: admin (default)
Status, System, Service, Network, LoRa, and Logout tabs are displayed at the top of the page. If you want to change the administrator password, please click System-Administration then input the new password and click Save & Apply.
4.2Modifying Network Parameters
Please follow the below steps to modify network parameters:
Step1: Click Network-Interface, then the Ethernet and WiFi configuration can
be found in this page.
Step 2: Click WAN-Edit, the General Setup (Ethernet static IP configuration or DHCP configuration) can be modified. The default configuration is DHCP mode.
Step 3: The Use gateway metric needs to be configured to 5 during DHCP configuration.
Step 4: Set up the static IP address.
Note: If gateway connects to LinkWAN platform (that is NS from Ali cloud
platform) .Set up the following DNS address: 223.5.5.5 or 223.6.6.6
Step 5:Click Save and Apply. The configuration is active.
Step 6:Step 4: Click Network-WiFi to enter the WiFi configuration page.
Step 7: Click Edit in the Client mode. The ESSID of the AP that will be connected can be set.
Step 8: Click Wireless Security, modify the key, then click Save & Apply to wait for connecting.
Step 9: If WiFi parameters modification is done, the AP connected and IPV4 address acquired can be displayed on the Associated Stationsin WiFi page.
NOTE: The Master mode is only used by technicians, so please do not do
any modification under this model.
4.3Modifying LoRa Parameters
Please follow the steps below to modify LoRa parameters:
Step 1: Click LoRa on the overview page and enter the LoRa configuration page,
which is composed of three parts: Version Configuration, Base Configuration,
Radio, and NS Server Configuration.
Step 2Gateway EUI can be shown in Base Configuration.
Step 3: Different LoRa frequency bands can be chosen in Radio Configuration.
Step 4: In the radio and NS configuration column, UDP and MQTT communication
modes are supported
In UDP mode, you can select the actual Lora band from the drop-down menu, and
configure the DNS server address (default: 0 gear. easy linking-ns.com ), NS Server Port up( default:1700 )NS Server Port down(
default:170 NM Server Addr(default:
api.easylink.com, and NM Server Portdefault:80 )
In MQTT mode, you can configure the information of the MQTT proxy server.MQTT
protbuf_coding_method is true for protobuf encoding and false for JSON
encoding.
After configuration, click the Save & Apply button in the bottom right corner
of the page.
Remarks
Only UDP mode can configure ns server address, and MQTT does not have this
configuration item;
4.4Customized Configuration
MQTT mode:
Step 2. Set up parameters as needed. For example, in keep-alive intervals, the
frequency can be configured.
Step 3. After any modification, do not forget to click Save & Apply button.
4.5Timezone Configuration
Step 1. Click System on the overview page and enter the System configuration
page.
Step 2. Select the corresponding time zone as needed. If connect to the Ali
LinkWAN platform, please choose UTC 0 time zone.
Step 3. After configuration, click Save & Apply to make the settings
effective.
4.6Restart Gateway
After all configurations/modifications are completed, select System->Reboot,
and click the Perform reboot button to restart the gateway. All
configurations/modifications will take effect after the gateway restarts.
INSTALLATION
G200 Series gateway has three installation methods:
- Desktop: Put the gateway on a flat surface such as the top of a table. Then adjust antenna direction accordingly, which is suitable for temporary demonstration and debugging.
- Wall mounting: Attach the gateway on the wall with the installation kit to mount it using the expansion tube and the adjustable screws.
- Ceiling mounting: Attach gateway on the ceiling with an installation kit to mount it using an expansion tube and adjustable screws.
5.1WallMounting
Install the gateway packet:
Step 1:Select the installation position on the wall and mark the locations
where the screw holes for the screws will be drilled.
Step 2: Drill holes (05) in the wall and plug-in plastic extension pipes
(PA4.0*30mm), then place the gateway bracket onto the marked location with
holes aligned.
Step 3: Tighten the screw.
Place gateway into bracket:
Step 1: Connect WiFi/LoRa antennas.
Step 2: Connect the power adapter, connect the Ethernet cable. When the
gateway is powered on, check the LED status. Make sure the gateway is working
normally.
Step 3: Attach gateway to bracket, make the hook in the gateway align to the
bracket grooves, push the gateway upward ( in a direction shown with a blue
arrow ) and lock it to the bracket.
5.2Ceiling Mounting
Ceiling mounting is almost the same as wall mounting except that the bracket
needs to be installed under the ceiling.
NOTES:
-
The gateway should be handled gently without violent collisions and drops.
-
The gateway should be mounted on a flat and dry surface with little dust and good ventilation. Do not expose the gateway to rain, water leakage, and any humidity.
PACKAGE LIST
NO | Photo | Name | Quantity(PCS) | Note |
---|---|---|---|---|
1 | G200 Gateway | 1 | ||
2 | Power Adapter | 1 | FCC/U L/CE/CCC | |
3 | RF Antenna | 1 | ||
4 | WiFi Antenna | 1 | ||
5 | Bracket | |||
6 | Product Specification | 1 | ||
7 | Certificate & Warranty Card | 1 |
FCC STATEMENT
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help with important announcements.
RF exposure warning: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment shall be installed and operated with a minimum distance of 20cm between the radiator & body.
SUPPORT
If you have any questions or problems with our gateway, please contact us for support.
EasyLink Address: Room 15D, 15th Floor, Microsoft Cogo Building,
Gaoxin South 5thRoad, Nanshan District, Shenzhen, China
Email: Service@EasyLinkin.com
Tel: +86 0755 2692 5175
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>