POTTER AMS-39 Series Standard Surface Mount Contact Owner’s Manual
- June 9, 2024
- POTTER
Table of Contents
AMS-39 Series Standard Surface Mount Contact
Owner’s Manual
AMS-39 SERIES
STANDARD SURFACE MOUNT CONTACT
AMS-39 Series Standard Surface Mount Contact
- UL and ULC Listed
- ¾” operating gap
- Spacers and covers included
- Available in white, brown, gray, or ivory*
Application
The AMS-39 Series Standard Surface Mount Contact us a UL listed contact designed to protect a wide variety of openings such as: man doors, sliding doors, windows, cabinets, hatches, and many others.
Dimensions
Specifications
Model| Color| Stock
Number| Contact| Contact
Rating| Contact
Type| Max. Carry
Current| Max.
Switching
Current| Breakdown
Voltage| Operating
Gap| Mounting
Method| Operating
Temperature
Range
---|---|---|---|---|---|---|---|---|---|---|---
AMS-39| White| 4350190| Terminal| 10 VA| Form A N.O| 1.0 Amp| .4 Amp| 200 VDC|
¾| Screw| 32° F to 120° F
(0° C to 49° C)
Brown| 4350187
Gray| 4350188
Ivory| 4350189
AMS-39B| White| 4350204| 3 VA| Form C
N.O./N.C.| .5 Amp| .2 Amp| 150 VDC
Brown| 4350202
Ivory| 4350078
AMS-39CVS
(includes screws,
covers, and spacers)
5 sets per pack| White| 4350186| 10 VA| Form A
N.O.| 1.0 Amp| .4 Amp| 200 VDC
Brown| 4350184
Gray| 4350067
Ivory| 4350185
- AMS-39B not available in gray
Potter Electric Signal Co., LLC
St. Louis, MO
Cust Service: 866-240-1870
Tech Support: 866-956-1211
Canada 888-882-1833
www.pottersignal.com
PRINTED IN USA
MKT. #8880118 – REV B