VisuScience VMC-100 Meibomian Gland Imaging Camera User Manual

June 9, 2024
VisuScience

VisuScience VMC-100 Meibomian Gland Imaging Camera

Product Features

  1. It can quickly capture clear meibomian glands images.
  2. It can be attached on smartphones or put on the slit lamp to capture images. It is very compact and convenient which can be carried away for outdoor examination or in bed patient examination.
  3. The corresponding image management application VisuDoc can capture and manage images on users’ smartphones either locally or on cloud.

Note: VisuScience does not store any image and/or patient’s information.

Product Specifications

Sensor| 5M megapixels (VMC-100)

10M megapixels (VMC-200)

---|---
Preview Resolution| 1920 x 1080, 25fPs
Image Resolution| 2592 x 1944
Image Format| JPEG
Data transfer| Wi-Fi
Power| 3.7V/2000mAh, 7.4Wh, Li-ion battery
Working Time| 4 hours
Charging Time| 2 hours
Recharging| Type-C USB cable DC 5V 1A
Charging Power| AC 110~220V ±10%, 50/60Hz
Product Dimension| 94mm x 68mm x 89mm (L/W/H)
Product Weight| 146g (with battery)
Working Environment| Temperature:+5℃ ~ +40℃ Relative Humidity:≤90%

Air Pressure:860hPa ~ 1060hPa

Storage Environment| Temperature:+5℃ ~ +40℃ Relative Humidity:≤90%

Air Pressure:860hPa ~ 1060hPa

Transportation Environment| Temperature:+5℃ ~ +40℃

Relative Humidity:≤90%

Air Pressure:860hPa ~ 1060hPa

Label and Symbols

VisuScience VMC-100 Meibomian Gland Imaging Camera
\(1\)

Packing List

No. Spare Part Name Quantity
1 Meibomian gland imaging camera 1pc
2 Power Adaptor 1pc
3 Type-C USB Cable 1pc
4 USB (VisuDoc Windows software) 1pc
5 User manual 1pc
6 Zipper bag 1pc
7 Slit lamp attachment 1pc (option)

Application

The MeiboVue is used to capture meibomian gland images. MeiboVue does not have diagnosis and measuring function.

Product Structure

VisuScience VMC-100 Meibomian Gland Imaging Camera
\(2\)

Software Installation

  1. Install VisuDoc Windows version Please copy the installation software ‘VisuDoc Windows-installer.exe’ from the USB disk to PC with Windows 10 system. Double click to install. VisuScience VMC-100 Meibomian Gland Imaging Camera \(4\)
    • Click ‘VisuDoc.exe’ to run the software.
    • If the port number of VisuDoc has conflict with other software installed in this PC, please input any other 4 digits to reset port number.VisuScience VMC-100 Meibomian Gland Imaging Camera \(6\)
  2. VisuDoc provides two data storage options: Local and Cloud. Please set the server according to the preferred storage option.
  • Local Storage The image captured and patient information will be stored in the local PC. Click ‘server setting’ and select ‘Local’. Input server PC’s IP address in LAN and the default port number is 9991.VisuScience VMC-100 Meibomian Gland Imaging Camera \(7\)
    • Click ‘Test’ to see if the connection succeeds. If the connection succeeds, click ‘Save’ to save the setting. The ‘Server Setting’ button will be green when connection succeeds.
    • For any other PC installed VisuDoc Windows PC, as long as it put same IP address of the server PC, it can visit the image and patient data on the sever.
  • Cloud Storage To store the images and patient information on cloud, please contact VisuScience to operate cloud implementation for you. Click ‘server setting’ and select ‘Cloud’, input IP address and port number.VisuScience VMC-100 Meibomian Gland Imaging Camera \(9\)
    • Click ‘Test’ to see if the connection succeeds. If the connection succeeds, click ‘Save’ to save the setting. The ‘Server Setting’ button will be green when connection succeeds.
  • Click ‘VisuDoc AMS’ to open VisuDoc account management system.
  • Input ‘Admin’ in username and the default password is ‘visu20211111’. Click ‘Login’.VisuScience VMC-100 Meibomian Gland Imaging Camera \(12\)
  • Click ‘User’ tab, click ‘Create’ button to enter new user creation interface. VisuScience VMC-100 Meibomian Gland Imaging Camera \(13\)
  • Input user name and password. This account information will be used as login info for VisuDoc App.
    • ‘Is Admin’: if it is selected, the user account will have access to login VisuDoc AMS.VisuScience VMC-100 Meibomian Gland Imaging Camera \(14\)
  • Click ‘Report Setting’ to input hospital information for PDF report template.VisuScience VMC-100 Meibomian Gland Imaging Camera \(15\)
  • Prepare a smartphone to work with MeiboVue. Download VisuDoc app from Google Play Store or App Store and install.VisuScience VMC-100 Meibomian Gland Imaging Camera \(16\)
  • Open VisuDoc app in the smartphone and click ‘Server setting’. Select ‘Cloud’ or ‘Local’. Input the same address and port number as you did in PC server setting. Then click ‘test’ and ‘save’. After successful connection, input the user account name and password created in VisuDoc AMS.’

Device Installation

  1. Take out MeiboVue device and tear off the protection film on the lens.

  2. If you use slit lamp attachment (optional), open the dust cover on bottom of the device and install the attachment to the slot. Fasten the screw in clockwise. If you want to take off the slit lamp attachment, please loosen the screw in counterclockwise.

    • Then, install the slit lamp attachment to the slit lamp’s base. Fasten the screw in counterclockwise to lock it firmly on the slit lamp’s base
      Warning: The forehead supporting is only applied when user operates MeiboVue by handheld. If the MeiboVue is installed on slit lamp’s base, please flip the forehead supporting to avoid causing damage to patient’s eyes.
  3. Please put smartphone onto the phone clip on MeiboVue. Please make sure the smartphone is firmly fixed by the clip to avoid falling down.

Product Operation

  1. . Long press the power switch for 4 seconds and the blue light indicator will be on.
  2. Connect the device with a PC through a USB cable.
  3. Open the folder on the PC and open following file wpa_supplicant.conf with txt software.
  4. Input the wifi spot name and password in the file like below:VisuScience VMC-100 Meibomian Gland Imaging Camera \(21\)
  5. Switch off the device and disconnect with PC.
  6. Switch on the device and the device will be in connection with wifi spot.

Product Charging

MeiboVue can be used continuously for 4 hours after fully charged. When the power is less than 20%, the power switch light indicator will flick to remind user to recharge the device. When the power is less than 20%, the user can still use the device for 10 minutes and after 10 minutes, the device will be powered off automatically.

To recharge the device, insert the type-C cable into the Type-C port on device and then insert USB port on the plug. When the device is being recharged, the blue light will be on and when the recharging is finished, the green light will be on. It takes 2 hours for the device to finish recharging from zero power.

Caution:

  1.  To maintain the lifespan of the battery, when the device shows low voltage reminder, please recharge it promptly.
  2. Please use the power adaptor and Type-C USB cable provided by the manufacturer to recharge MeiboVue.

Product Maintenance and Cleaning

  1. Please make sure the camera is firmly attached to smartphone when using the device.
  2. Please don’t put any container filled with fluid near the device.
  3. Please power off when the device is not in use and put it into the packing box.
  4. Please take out the battery if the device will not be used for over one month.
  5. The device life span is 3years in good maintenance condition.
  6. Please don’t touch the lens protect cover with fingers. The dirt on lens protection cover will affect the image quality captured by the device.
  7. User can only clean the surface of the device by following instructions below:
    • Lens Protection Cover
    • Please blow the dust on the surface.
    • Use clean and soft cloth to dip in glass detergent and clean it from the center to the peripheral in circle way. Please make sure not scratch the lens cover during the cleaning.
    • After operating the cleaning method mentioned above, if there is still dirty on the surface, please don’t continue cleaning the lens cover to avoid damage to the surface.
    • Other surface on the device
    • Please use the soft cloth to clean device surface other than the lens protection cover.
    • Please avoid the label and symbol on the device during cleaning.

Problem Shooting

No. Problem Solution
1 Cannot switch on device 1.    Long press power switch for 4seconds

2.     The device is in low power. Please recharge the device.

2| The smartphone cannot find MeiboVue Wi-Fi spot| 1.    Please refresh the Wi-Fi list after the device is switched on for 20 seconds.

2.     The device is in low power. Please recharge the device.

Maintenance Term

VisuScience Meditech Co., Ltd. provide one year warranty to the device upon installation of the device.

Disclaim

  1. VisuScience Meditech Co., Ltd. will not hold responsibility for damage caused by fire, earth quake, their party behavior or other abuse by the user.
  2. VisuScience Meditech Co., Ltd. will not hold responsibility if the device is not able to be used because of the company loss or close down.
  3. VisuScience Meditech Co., Ltd. will not hold responsibility for the operations conducted by the user that is not mentioned in this user manual.
  4. VisuScience Meditech Co., Ltd. will hold no responsibility for the diagnosis given by the doctors.

FCC Statement

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help

This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions (1)this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

CE Statement Herby, VISUSCIENCE MEDITECH CO., LTD. declares that this Meibomian Gland Imaging Camera,VMC-100 is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. In accordance with Article 10(2) and Article 10(10), this product allowed to be used in all EU member states. Use the Meibomian Gland Imaging Camera in the environment with the temperature
between 5℃ and 40℃ Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. The product shall only be connected to a USB interface of version USB2.0 5150-5250 indoor use only. Adapter shall be installed near the equipment and shall be easily accessible. The plug considered as disconnect device of adapter

  • Adapter Model: UES06WNCPU-050100SPA
  • Input: AC 100-240V 50/60Hz 0.2A Output: DC 5.0V, 1.0A
  • Operating frequency: 5150MHz-5350MHz, 5470MHz-5725MHz, 5725MHz~5875MHz
  • Max output power: 5G WIFI: 0.0366W
  • Manufacturer: VISUSCIENCE MEDITECH CO., LTD.
  • Address: Room 718-720, No. 208 Guangyi Road, Wuxi, Jiangsu Province 214016, China
  • E-mail: info@visuscience.com
  • Importer: SUNGO Europe B.V.
  • Address: Fascinatio Boulevard 522, Unit 1.7, 2909VA Capelle aan den lJssel, The Netherlands

VisuScience VMC-100 Meibomian Gland Imaging Camera
\(22\) VisuScience VMC-100 Meibomian Gland
Imaging Camera \(23\)

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VisuScience User Manuals

Related Manuals