SPECIFICATIONS

PARTS

  • Tritan safety material

  • High temperature resistant

  • Shatter resistant

  • Bisphenol free

  • Electrolysis base unit

  • SPE/PEM technology, dual chamber electrolysis technology.

  • Multifunctional cover

  • Pressure release valve

  • Hydrogen/Oxygen tube attachment

WATER BOTTLE ATTACHMENT

  • Connect a single-use plastic water bottle using the Thread Adaptor
  • When using a single-use plastic bottle, please run a cycle for no longer than 5 minutes. (We cannot guarantee the durability of the plastic against pressure.)

HYDROGEN INHALATION TUBE

  • The Hydrogen Inhalation Tube attaches to the pressure release valve.

PRODUCT DESCRIPTION

  • This product is a high concentration Hydrogen Water Generator.
  • It uses a method of electrolysis that results in the release and separation of hydrogen and oxygen.
  • High concentration hydrogen is freed from ordinary drinking water then dissolved into the water via air-sealed pressure in order to produce “dissolved molecular hydrogen” within the water.
  • This portable model is ideal for any use, or when travelling or on the move.

SET UP BEFORE USE

  • When using it for the first time, please remove the sealing cap on the electrolyte cell inside the base unit, then pour out any remaining liquid, if any remains.
  • Before activation please fill the machine up halfway with clean/pure water, then leave soaking for 4-8 hours. This will allow the ion membrane to soak completely. Please do not use the machine before completing this step.
  • Once soaking is completed, rinse and fill with clean/pure water to the maximum line or less. Activate/use as normal.
  • The ion membrane may be in a dry state at first, there may be less hydrogen concentration, this is normal. After 1-2 cycles, it may improve.
  • If there are still too few bubbIes during cycles, please use warm water no more than 60°C to further activate the ion membrane.

OPERATIONAL INSTRUCTIONS

  • Unscrew the machine lid. Add pure/filtered water.
  • Fill the machine up to the yellow (Maximum) line (seen on the container) and never beyond. If you fill beyond the line you risk breaching the membrane which can cause leaking.
  • Ensure the lid is sealed.
  • When the machine is active/running it will light up blue and you will see oxygen bubbles rise.
  • Press Once to run a cycle for 5 minutes. (It will beep once)
  • Press again (Twice) to run a cycle for 10 minutes. (It will beep twice)
  • After each 5 or 10 minute cycle, please release the pressure by pressing the top valve or twisting open the lid. Do not run a cycle beyond 10 minutes without first releasing the pressure.

BUTTON INDICATOR STATUS

  • Charging (not in use): Red light is on.
  • Fully charged (not in use): Green light is on.
  • Charging during a cycle: Purple light is on.
  • Fully charged during a cycle: Cyan light is on.
  • Battery low during a cycle: The blue light is always on and the red light flashes slowly.

SAFETY & CARE

  • Do not put any conductive metal or food inside the machine.
  • Use only pure filtered water. If you use hard or unfiltered water, the machine may degrade and will void the warranty.
  • Be sure to keep the electrolyte cell inside the cup wet/moist at all times to prevent the ion membrane from drying.
  • Do not run a cycle for more than 10 minutes without first releasing pressure.
  • Keep outside of the machine dry. Do not dishwasher clean or deep soak the base unit.
  • Keep away from fire, heat or flames.
  • Not to be used by children.

CLEANING INSTRUCTIONS

  • Recommended cleaning is once a week.
  • Soak or rinse the machine with clean water.
  • Hand wash only.
  • Use a cleaning brush that will not damage the material or electrolyte cell. A soft sponge is recommended.
  • If scaling builds up on the cell, soak the machine with 1-2 tablespoons of citric acid or vinegar (preferably in warm water). Leave for 1-4 hours. Rinse before use.
  • Do not use detergent or chemicals on the unit when cleaning.

PROBLEMS & SOLUTIONS

  • Bubbles decreasing over time : During eIectroIysis gas is continuously generated inside the machine. It is normaI to see bubbles decrease towards the end of a cycle. Alternatively it could be due to built up scale, that needs to be cleaned.
  • When water is eIectroIyzed, Iarge and smaII bubbIes are generated : SmaII bubbIes gather at the bottom to form large bubbles that float, which is normaI.
  • There are bubbIes when the machine is producing hydrogen, but the Iight does not light up : The LED Iight is damaged.
  • Machine leaking : When the machine is running a cycle, you may notice water leaking from the bottom of the base. This is a normal process of waste water release.
  • Charge not holding : Not using the correct charger or charging time.

WARRANTY POLICY

https://H2Grail.com/policies/refund-policy