Remove battery and nails from magazine. Proceed to the next step accordingly.

TO RESET STRIKER

  1. Check for incorrect striker position, it may or may not be visible. If striker does not require a reset, see steps for clearinga jammed nail.
  2. Adjust contact bracket all the way out to the minimum depth. Attach charged battery. Power tool back on.
  3. Press contact bracket against a hard surtace that can be damaged. Pull and hold back the nail pusher. Fire tool. You will hear striker reset itself.
  4. Remove battery. Load nails back in tool. Re-attach battery. Tool is now ready for use.

TO CLEAR JAMMED NAIL

  1. Remove the magazine using the provided hex tool to unscrew the 3 screws highlighted in the photo.
  2. Check for jammed nail.
  3. Use tool to remove jammed nail.
  4. Line up and re-attach the magazine. Reload the magazine and re-attach battery. Tool is now ready for use.