KMC CONTROLS BAC-1x0063CW FlexStat Controllers Sensors User Guide

June 9, 2024
KMC CONTROLS

KMC CONTROLS BAC-1x0063CW FlexStat Controllers Sensors

Use this document to facilitate FlexStat model selection according to desired applications and options. For additional specifications, see the BAC- 12xxxx/13xxxx Series FlexStat Data Sheet (914-035-01). Additional award- winning resources for configuration, application, operation, programming, upgrading and much more are available on the KMC Controls web site (www.kmccontrols.com). To see all available files, you will need to log-in to the KMC Partners site.

Model Code

  • BAC-120036C (No Optional Sensors or Communication, 3 Relays, 6 Analog Outputs, Light Almond)
  • BAC-120163CEW (Optional Humidity Sensor, 6 Relays, 3 Analog Outputs, Optional Ethernet/ IP Communication, White)
  • BAC-121136CW (Optional Humidity and Motion Sensors, 3 Relays, 6 Analog Outputs, White)

Sensor Options

Temperature (Standard)

  • Internal temp. sensor standard on all models.
  • Optional remote temperature sensor (connected to IN7) allows configuration for onboard (internal), remote, averaging of the two, the lowest reading, or the highest reading.

Humidity

  • BAC-1xx1xxC.
  • For optional dehumidification (AHU, RTU, HPU, or 4-pipe FCU) or humidification (AHU, RTU, or 4-pipe FCU).
  • Comes standard when optional CO2 sensor (BAC-13xxxxC) is ordered.

Motion/Occupancy

  • BAC-1x1xxxC.
  • For optional occupancy standby and/or override.

CO2 with DCV (Demand Control Ventilation)

  • BAC-12xxxxC = No internal sensor, but has built-in DCV sequences and IN9 can be configured for remote CO2 sensor.
  • BAC-13xxxxC = Internal sensor (with ABC Logic) for applications where concentrations will drop to outside ambient conditions at least three times in a 14 day period. The BAC-13xxxx series (only) has been certified to comply with CA Title 24, Section 121(c), as well as sub-paragraph 4.F.

NOTE: DCV is only available when using an AHU, RTU, or HPU application with a modulating economizer option enabled. For additional important information about the CO2 sensors and DCV, see the FlexStat Data Sheet and FlexStat Operation Guide!

Application Options

  • Supported AHU, FCU, HPU, and RTU options depend on whether the FlexStat is a BAC- 1xxx36C (3 relays and 6 analog outputs) or a BAC-1xxx63C (6 relays and 3 analog outputs).
  • See Applications and Models on page 4.

BACnet Network Communication Options

MS/TP (Standard)

  • Integral peer-to-peer BACnet MS/TP LAN network communications standard on all models, including those with Ethernet/IP option.
  • Screw terminal blocks accept twisted-pair wire size 14–22 AWG, and a data port on the underside of the case enables easy temporary computer connection to the BACnet network (access with a KMD-5624 cable—requires use of KMD- 5576 or third-party interface).

IP/Ethernet

  • BAC-1xxxxxCE.
  • “E” versions add BACnet over Ethernet, BACnet over IP, and BACnet over IP as Foreign Device.
  • “E” versions add RJ-45 jack for Ethernet cable.

Color Options

White (Standard)

  • BAC-1xxxxxCW.
  • Standard on all models.

Light Almond

  • BAC-1xxxxxC (W removed).
  • Optional on all models.

Applications and Models

Model Chart

For additional specifications, see the BAC- 12xxxx/13xxxx Series FlexStat Data Sheet (914- 035-01).

NOTE: For specifications on the older BAC-10000 Series FlexStats (with only three external inputs and no Ethernet or CO2 options), see the data sheet (913- 035-01) for that series.

FlexStats come with a printed Installation Guide. Additional award-winning resources for configuration, application, operation, programming, upgrading, and much more are available on the KMC Controls web site (www.kmccontrols.com). To see all available files, you will need to log-in to the KMC Partners site.

Accessories

Damper (OAD/RTD) Actuators (Fail-Safe)

  • MEP-7552 22.5 ft2 max. damper area, 180 in-lb., 0–10 VDC, 25 VA
  • MEP-7852 40 ft2 max. damper area, 320 in-lb., 0–10 VDC, 40 VA

Mounting Hardware

  • HMO-10000 Horizontal or 4 x 4 handy box wall mounting plate for BAC- 12xxxx models (not needed for BAC-13xxxx models), light almond (shown)
  • HMO-10000W HMO-10000 in white
  • SP-001 Screwdriver (KMC branded) with flat blade (for terminals) and hex end (for cover screws)

Network Communications and Firmware

  • HTO-1104 FlexStat firmware upgrade kit
  • KMD-5567 Network surge suppressor
  • KMD-5575 Network repeater/ isolator
  • KMD-5624 PC data port (EIA-485) cable (FlexStat to USB Communicator)— included with the KMD-5576 (buy for third-party EIA- 232 interfaces)

Relays (External)

  • REE-3112 (HUM) SPDT, 12/24 VDC control relay

Sensors (External)

  • CSE-110x (FST) differential air pressure switch
  • STE-1402 (DAT) duct temperature sensor with 8-inch rigid probe
  • STE-1416 (MAT) flexible 12-foot duct averaging temp. sensor
  • STE-1451 (OAT) outside air temp. sensor
  • STE-6011 Remote space temp. sensor
  • SAE-10xx Remote CO2 sensor, space or duct
  • STE-1454/1455 (W-TMP) 2-inch strap-on water temp. sensor (with or without enclosure)

Transformers, 120 (or more) to 24 VAC (TX)

  • XEE-6111-040 40 VA, single-hub
  • XEE-6112-040 40 VA, dual-hub
  • XEE-6311-050 50 VA, dual-hub
  • XEE-6311-075 75 VA, single-hub
  • XEE-6311-100 96 VA, dual-hub

Valves (Heating/Cooling/Humidification)

  • VEB-43xxxBCL (HUMV/CLV/HTV) Fail-safe control valve, w/ MEP-4×52 proproportional actuator, 20 VA
  • VEB-43xxxBCK (VLV/CLV/HTV) control valve w/ MEP-4002 proportional actuator, 4 VA
  • VEZ-4xxxxMBx (VLV/CLV/HTV) failsafe control valve, 24 VAC, 9.8 VA

NOTE: For details, see the respective product data sheets and installation guides. See also the FlexStat Application Guide.

19476 Industrial Drive New Paris, IN 46553, U.S.A. www.kmccontrols.com info@kmccontrols.com

To Order:

  • Telephone: 877.444.5622 (574.831.5250)
  • Fax: 574.831.5252
  • This document is printed, using ink that is  environmentally friendly, on recycled (30% PCW and 55% total recycled fiber) paper.
  • FlexStat is a trademark and KMC Controls is a registered trademark of KMC Controls, Inc.