Remii 102745-XT 45 In Extra Tall Deep Built In Electric Fireplace Instruction Manual

June 9, 2024
Remii

102745-XT 45 In Extra Tall Deep
Built In Electric Fireplace
Instruction Manual

SAFETY INFORMATION

WARNING
If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
Please read and carefully follow all of the instruction found in this manual.
Please pay special attention to the safety instructions provided in this manual. The instructions  included here will assure that you have many years of dependable and enjoyable service from your Remii product.

IMPORTANT INSTRUCTIONS

  1. Read all instructions before installing or using this heater.
  2. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet from the front of the heater; keep them away from sides and  rear as well.
  3. Always unplug heater when it’s not in use.
  4. Do not operate the fireplace if it has a damaged cord or plug, after it has malfunctioned, or if the unit has been dropped or damaged in any way.
  5. Never place the heater where it may fall into a bathtub or other water containers.
  6. Do not run the cord under carpeting. Do not cover the cord with throw rugs, runners or anything else. Arrange the cord away from traffic areas where it could not be  tripped over.
  7. To disconnect the heater, turn the controls to “OFF” before removing the plug from the outlet.
  8. Do not insert or allow foreign objects to enter any ventilation or exhaust opening, as this may cause an electric shock, fire or damage to the heater.
  9. To prevent a possible fire, do not block air intakes in any manner.
  10. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids are used or stored.
  11. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
  12. Avoid the use of an extension cord because the extension cord may overheat and cause a fire.
  13. Always use properly grounded fused and polarized outlets.
  14. Always use ground fault protection where it is required by electrical codes.
  15. Always disconnect the power before performing any cleaning, maintenance or relocation of the heater.
  16. To prevent a possible fire, do not burn wood or other materials in this heater.
  17. To prevent electric shock or fire, always use a certified electrician, should new circuits or outlets be required.
  18. When transporting or storing the heater, keep it in a dry place, free from excessive vibration.

UNPACKING AND TESTING APPLIANCE
Carefully remove the appliance from the box. Prior to installing the appliance, test to make sure the appliance operates properly by plugging the power supply cord into a  conveniently located 120 Volt grounded outlet.

GROUNDING APPLIANCE

This appliance is for use on 120 Volts. The cord has a plug as shown in (A). An adapter as shown in (C) is available for connecting three-blade grounding type plugs to two- slot receptacles. The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should  not be used if a three-slot grounded receptacle is available.
To disconnect appliance, turn controls to off, then remove plug from outlet.

LOCATING THE FIREPLACE

Plan where to locate and frame the fireplace. This will save time and money later when you install the fireplace. Before installation consider the following:

  1. Where the fireplace is located must allow for wall and ceiling clearances (see INSTALLATION)
  2. Consider a location where the fireplace screen will not be exposed to direct sunlight from windows or doors.
  3. A 15 ampere, 120 Volt, 60 Hz branch circuit with proper ground must be available at the location.
    Preferably a dedicated branch circuit should be provided to avoid circuit breakers to trip of fuses to blow.

102745-XT

Description Built-in Appliance
Voltage 120V AC 60Hz
Watts 1465W Max
NO HEATER 25W
MOTOR HEATER 19W
Appliance Width 43 5/8” or 110.8 cm
Appliance Height 29 1/2” or 75 cm
Appliance Depth 12 5/8” or 32.2 cm
Gross Weight 94.6lbs or 43kg
Plug Location Left side
Cord Length 70 7/8” or 180 cm
Rough Wall Opening Size 45”× 30“ or 104.3 cm× 76.2 cm
BTU 5000

This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you  need assistance during installation, please contact your local dealer.
NOTE: This appliance must be electrically wired and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 Canadian Electrical  Code in Canada or the ANSI/NFPA 70 National Electrical Code in the United States.

102755-XT

Model Number Built-in Appliance
Voltage 120V AC 60Hz
Watts 1465 W Max
NO HEATER 25W
MOTOR HEATER 19W
Appliance Width 53 5/8” or 136.2 cm
Appliance Height 29 1/2” or 75 cm
Appliance Depth 12 5/8” or 32.2 cm
Gross Weight 110lbs or 50kg
Plug Location Left side
Cord Length 70 7/8” or 180 cm
Rough Wall Opening Size 55”× 30“ or 139.5 cm×76.2 cm
BTU 5000

This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you  need assistance during installation, please contact your local dealer.
NOTE: This appliance must be electrically wired and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 Canadian Electrical  Code in Canada or the ANSI/NFPA 70 National Electrical Code in the United States.

102765-XT

Description Built-in Appliance
Voltage 120V AC 60Hz
Watts 1465W Max
NO HEATER 25W
MOTOR HEATER 19W
Appliance Width 63 5/8” or 148.5 cm
Appliance Height 29 1/2” or 75 cm
Appliance Depth 12 5/8” or 32.2 cm
Gross Weight 127.6lbs or 58kg
Plug Location Left side
Cord Length 70 7/8” or 180 cm
Rough Wall Opening Size 65”× 30“ or 165.1 cm× 76.2 cm
BTU 5000

This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you  need assistance during installation, please contact your local dealer.
NOTE: This appliance must be electrically wired and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 Canadian Electrical  Code in Canada or the ANSI/NFPA 70 National Electrical Code in the United States.

SAFETY DRILL SCREW AREA

There is a safety drill screw area as show below.
Please make sure that the fix screws are in this area.

HARD- WIRE INSTALLATION

Turn off the appliance completely and let cool before servicing. Only a qualified service person should service and repair this electric appliance.
If it is necessary to hard wire this appliance, a qualified electrician must remove the cord connection, and wire the appliance directly to the household wiring.
This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In the absence of local codes, use the current CSA C22.1  CANADIAN ELECTRICAL CODE in Canada or the current ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.

  1. Remove the cover plate from the left side of the appliance by removing the two screws, as shown below. Unscrew and remove power cord.
  2. Attach the wiring to the junction block. Please make sure the live wire goes into the “L”, the neutral wire into “N” and the ground wire into “G”.
  3. Put the plate back and screw back.

FOR BATHROOM USE

If this unit is installed in a bathroom it must be protected by a GIF receptacle or circuit. If receptacle is used it must be readily accessible.
To prevent electric shock, please be aware that this unit is an electrical appliance that is NOT watertight and must be installed as to prevent water from entering unit. This  must be installed away from shows, tubs, etc. Never locate fireplace where it may fall into a bathtub or other water container. All wiring connections to line power shall be in  accordance with local building code requirements.
Inquires about local codes and regulations must be done prior to installation.

OUTDOOR INSTALLATIONS

The 102745-XT, 102755-XT and 102765-XT electric fireplaces are suitable for installation in outdoor areas protected from direct water impingement. In addition to  maintaining the listed mantel and combustibles clearances, a rain protection overhang factor of 1/2 shall be constructed to the front and to each side of the installed  appliance. See illustration below. All wiring connections to line power shall be in accordance with local building code requirements. Inquires about local codes and regulations must be done prior to installation.

The overhang (A) must extend at least 1/2 the roof-line height (B).
Height is measured from the base of the fireplace.
For example: if the roof-line (B) is 8’ above the base of the fireplace, the overhang (A) must be at least 4’.

INSTALLATION

The 102745-XT, 102755-XT and 102765-XT models are designed to be built-in. These units allow for the finishing material (drywall, stone, tile, etc) to be built right down to  the glass edge. However, that application is not always desirable or available so the surround could be used as an alternate finish option.
Important note: The optional surround is not firmly attached and can be removed from the unit by simply pulling it off. It is recommended that two people remove the  surround.

The rough wall opening size of the fireplace:

| W(")| D(")| H(")
---|---|---|---
102745-XT| 45| 12 1/2| 30
102755-XT| 55| 12 1/2| 30
102765-XT| 65| 12 1/2| 30

  1. Take out the unit from the box. Please do the pre-test before you install the fireplace. Pull out the optional trim from the unit as shows below.

  2. Remove the framing plates from the unit

  3. Re-fix the framing plates to the unit as the picture shows

  4. Bend up the framing plates.

  5. Put the unit into the opening.

  6. Drive the mounting screws into the framing plates on the unit and the wall studs.

  7. After checking that the fireplace operates properly, cover the glass panel with protective plastic bag and install plywood or drywall.
    IMPORTANT NOTE: IF YOU WANT TO USE THE SUPPLIED SURROUND the thickness of the wall finish can only be 1”.

  8. Decorate the plywood or drywall with glazed tile, wallpaper, etc.

  9. Put back the trim that you’ve removed from the unit at STEP 1.

Media Options

The 102745-XT, 102755-XT and 102765-XT are shipped with two mixture media shows below: the Canyon brown and Ocean blue. Consumers may purchase optional decorative media if they choose.
See dealer for more details.

FIRE GLASS MEDIA-LOG INSTALLATION

  1. Take off the front clear glass. There is a bracket that holds the front glass as shows below.
    Unscrew the screw to take off the bracket. Turn around the bracket and insert it into the gap to hook and pull out the glass.

  2. Install the fire glass media. Pour the fire glass media into the try. Feel free to use any combination of fire glass media that you find most appealing.

  3. Put back the front glass after you finish the fire glass decoration.

OPERATION

The fireplace can be operated either by the switches located on the left bottom of the fireplace unit or by supplied remote control.
Plug the fireplace into a 15 Amp wall socket.

MANUAL OPERATION

  1. The main power ON/OFF switch in position O, the fireplace is OFF.

  2. When main power ON/OFF switch is at position I, the fireplace is ready to use.

  3. Press the button repeatedly to set the heater to desired heat setting. The heater indicator LED will glow which shows the current heater settings.
    a) RED 1465W HEAT OUTPUT
    b) BLUE 750W HEAT OUTPUT
    c) PURPLE AUTO MODE
    AUTO MODE
    Under this mode the heater will automatically turn ON at high heat setting 1465W heat output when the room temperature drops below 22℃(72 ℉ ). When the room  temperature is between 22-25℃(72-77℉) the heater output will switch to low heat setting 750W. When the room temperature goes above 25℃(77℉) the heater will be  turned off and the cycle will continue. The LED indicator will be PURPLE in colour under this mode.

  4. Flame effect: Press the button marked to adjust the flame brightness. The flame brightness will cycle through –Low-Medium-High -OFF.

  5. Mood light effect: Press the button marked to change the mood light colour.

NOTE: If operated at the Low heat setting, the fireplace will not provide as much heat output as in the High heat setting, however the low setting will not require as much  electrical power to operate.
To avoid overloading a circuit, do not plug the fireplace into a circuit that already has other appliances working. When the fireplace is not in use switch off and unplug.

SAFETY CUT-OFF

  • This appliance is fitted with a safety cut-off which will operate if the fireplace overheats (eg. Due to blocked air vents). For safety reasons, the fireplace will NOT  automatically reset.
  • To reset the appliance, disconnect the appliance from the main supply for at least 10 minutes.
    Reconnect the supply to the main and switch on the appliance.

REMOTE CONTROL OPERATION

For remote to function make sure the heater is plugged in and main power switch located on the bottom left hand side is at position I.
When operating the remote make sure you point the remote to the centre of the fireplace and make sure each time you press the button the buzzer inside the unit will beep  once. It takes some time for the receiver to respond to the transmitter. Do not PRESS the buttons more than once within two seconds for correct operation.
Power on button: The power-on button at top left corner of the remote is the main ON/OFF power button. This will turn off all the functions and the fireplace will be in standby mode.
DISPLAY ON/OFF button: Switching the fireplace flame and tray light ON/OFF. It has functions of setting memory.
DISPLAY BLUE button: Adjust the blue color brightness of flame and tray.
DISPLAY YELLOW button: Adjust the yellow color brightness of flame and tray.
DISPLAY ORANGE button: Adjust the orange color brightness of flame and tray.
MOOD LIGHT ON/OFF button: Switching the mood light ON/OFF.
ADJUST button: Switching the color of the mood light.
FLASH button: Switches the mood light into flash mode, this cycles through all mood light colors.
HEATER ON/OFF button: Switching the heater ON/OFF. It has functions of setting memory.
HIGH button: Press the high button to switch the heater to high heat setting 1465W.
LOW button: Press the low button to switch the heater to low heat setting 750W.
TEMP. button: Press the TEMP. button to switch the heater to AUTO mode. Under this mode the heater will operate in similar way as explained above for the manual operation.

INSTALLING WALL THERMOSTAT

WALL THERMOSTAT WIRING DIAGRAMS

Wire the wall thermostat prior to installing the fireplace.
WALL THERMOSTAT WIRING(24 VAC)
Install Wall Thermostat per instructions provided with kit and per the following information:

  1. Turn off circuit breaker.
  2. Remove cover plate located on the left side of appliance.
  3. Pull the wire out and cut the inside thermostat. Connect the wires to the wall thermostat as shown below. Follow instructions provided with wall switch kit.

REPLACEMENT PARTS

This list contains replacement parts

NO DESCRIPTION QTY.
102745-XT 102755-XT 102765-XT
1 602030C 602030C 602030C
2
3 10104010 SWITCH 1
4 601036 CONTROL PANEL 1
5 601092C CIRCUIT BOARD 1
6 10101225 FLAME MOTOR 2
7 3134504 3136504 3138504
8 601136B LED STRIP 4/6/8
601137B 2/2/2
9 10203015 ADJUSTABLE FOOT 4
10 10701264 10701266 10701268
PLASTIC 1
11 3057012 GLASS BRACKET LH 1
12 3057013 GLASS BRACKET RH 1
13 10702190 10702192 10702194
14 3111017 MEDIA HOLD BRACKET 2
15 3057016 FRONT GLASS BRACKET 2
16
17 10701256 10701258 10701260
18 3139501 BLACK STEEL SURROUND 1
19 10105063 REMOTE 1

EXPLODED VIEW

TROUBLE SHOOTING

PROBLEM POSSIBLE CAUSE SOLUTION
Dim or no flame Flame LED’s are burnt out Inspect the LED’s and replace them

if necessary.
Ember bed is not glowing or dimming| Ember LED’s are burnt out| Inspect the ember bed LED’s and replace them if necessary.
Appliance turns off and will not turn on| Appliance has overheated and safety device has caused the thermal switch to disconnect| Turn off the main switch, allow appliance to cool for 10 minutes, then turn it on.
House tripped circuit breaker has| Reset house circuit breaker.
Appliance’s fuse has blown| Replace the fuse.
Appliance will not come on when switch is flipped to ON| Appliance is not plugged into an electrical outlet| Check plug and plug in.
Appliance has overheated and safety device has caused the thermal switch to disconnect| Turn off the main switch, allow appliance to cool for 10 minutes, then turn it on.
Circuit board is burnt out| Inspect the circuit board and replace it if necessary.
No warm air coming out of appliance| Heater is burnt out| Inspect the burner and heater assembly and replace it if necessary.
Flame sputters| Flame motor is defective.| Call a qualified service technician and replace flame motor.
Remote Control does not work.| Low batteries.
Unit switch in “O” position.| Replace AAA batteries in control.
Turn the switch in “I” position. remote
Flame is fixed.| Wiring may be loose or the flame motor may be defective.|

SERVICE HISTORY

This heater must be serviced annually depending on usage.

Date| Dealer Name| Service technician Name| Service Performed| Special Concerns
---|---|---|---|---
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |

WARRANTY
Remii Electric Fireplaces (“Remii”) warrants that your newly purchased Remii electric fireplace is free from manufacturing and material defects for a period of two (2) years  from the date of the first purchase, subject to the conditions and limitations contained below.
Warranty Application & Exclusions
This limited warranty applies to your newly purchased Remii electric fireplace; the limited warranty’s application is limited to purchases made in any province of Canada or in  any of the 52 States of the United States of America, including the District of Columbia. Only the original purchaser of the product is eligible for coverage under this limited  warranty; the warranty is not transferable.

Products excluded from this limited warranty
Light bulbs are not covered by this limited warranty and are the sole responsibility of the owner/purchaser. Remii does not cover service or labor charges.

Warranty Coverage and Term
Products covered by this limited warranty have been tested and inspected prior to shipment and, subject to the provisions of this warranty, Remii warrants such products to  be free from defects in material and workmanship for a period of two (2) years from the date of the first purchase of such products.
The limited two (2) year warranty period for products also applies to any implied warranties that may exist under applicable law. Some jurisdictions do not allow limitations on  how long an implied warranty lasts, so the above limitation may not apply to the purchaser.
All other warranties—expressed or implied—with respect to the product, its components and accessories or any obligation/liabilities on the part of Remii are hereby  expressly excluded.

Limitations to Coverage Under Limited Warranty
This limited warranty does not apply to products that have been repaired, or otherwise altered. This limited warranty further does not apply to defects resulting from misuse,  abuse, accident, neglect, incorrect installation, improper maintenance or handling, or operation with an incorrect power source. Products made by other manufacturers, sold  with the product or thereafter, are not covered by this limited warranty. The use of unauthorized components will render this warranty null and void.

Outdoor Rated Units
All units that are installed outdoors or in moisture intense conditions must use the stainless steel cover/and or be installed with appropriate shelter. Proof of purchase of the  cover and/or shelter is required for any warranty claims.

Defects
Defects must be brought to the attention of the selling dealer. Please have your proof of purchase, catalogue/model and serial numbers available when contacting dealer; any  and all service under the limited warranty requires a proof of purchase of the product. Should a product or part covered by this limited warranty be proven to be defective, in  material or workmanship, and during the two (2) year limited warranty period, Remii will replace such defective product or part without charge. If Remii is unable to replace  such part, or if replacement is not commercially practicable or cannot be timely done, in its sole discretion Remii may, in lieu of replacement, choose to refund the purchase  price for such product or part. Remii does not cover labor or service charges to replace said parts.

Limitations
In no event will Remii, including without limitation any of its directors, officers, shareholders, employees, consultants, agents, heirs, executors, administrators and assigns, be  liable to the purchaser or any third party, whether in contract, in tort, or on any other basis for any indirect, special, punitive, exemplary, consequential, or incidental loss, cost  or damage arising out of or in connection with the sale, maintenance, use or inability to use the product, even if Remii, including without limitation any of its directors,  officers, shareholders, employees, consultants, agents, heirs, executors, administrators and assigns, have been advised of the possibility of such losses, costs or damages, or if  such losses, costs or damages are foreseeable. In no event will Remii, including without limitation any of its directors, officers, shareholders, employees, consultants, agents, heirs, executors, administrators and assigns, be liable for any direct losses, costs or damages that exceed the purchase price of the product.
Some jurisdictions do not allow the  exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to the purchaser.

Application of Provincial and State Law
This limited warranty gives you specific legal rights, and you may also have other rights which vary from jurisdiction to jurisdiction. The provisions of the United Nations  Convention on Contracts for the Sale of Goods shall not apply to this limited warranty or the sale of products covered by this limited warranty.

General
Remii reserves the right to make changes at any time without notice, in design, material, specifications, prices and the right to discontinue styles and products.

Remii Electric Fireplaces
502-1027 Davie Street
Vancouver, BC V6E4L2

Documents / Resources

| Remii 102745-XT 45 In Extra Tall Deep Built In Electric Fireplace [pdf] Instruction Manual
102745-XT 45 In Extra Tall Deep Built In Electric Fireplace, 102745-XT, 45 In Extra Tall Deep Built In Electric Fireplace, Built In Electric Fireplace, Electric Fireplace, Fireplace
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Remii User Manuals

Related Manuals