Remii 102745-XT 45 In Extra Tall Deep Built In Electric Fireplace Instruction Manual
- June 9, 2024
- Remii
Table of Contents
- SAFETY INFORMATION
- IMPORTANT INSTRUCTIONS
- GROUNDING APPLIANCE
- LOCATING THE FIREPLACE
- SAFETY DRILL SCREW AREA
- HARD- WIRE INSTALLATION
- FOR BATHROOM USE
- OUTDOOR INSTALLATIONS
- INSTALLATION
- Media Options
- FIRE GLASS MEDIA-LOG INSTALLATION
- OPERATION
- REMOTE CONTROL OPERATION
- INSTALLING WALL THERMOSTAT
- REPLACEMENT PARTS
- EXPLODED VIEW
- TROUBLE SHOOTING
- SERVICE HISTORY
- Documents / Resources
102745-XT 45 In Extra Tall Deep
Built In Electric Fireplace
Instruction Manual
SAFETY INFORMATION
WARNING
If the information in these instructions are not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
Please read and carefully follow all of the instruction found in this manual.
Please pay special attention to the safety instructions provided in this
manual. The instructions included here will assure that you have many years
of dependable and enjoyable service from your Remii product.
IMPORTANT INSTRUCTIONS
- Read all instructions before installing or using this heater.
- Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet from the front of the heater; keep them away from sides and rear as well.
- Always unplug heater when it’s not in use.
- Do not operate the fireplace if it has a damaged cord or plug, after it has malfunctioned, or if the unit has been dropped or damaged in any way.
- Never place the heater where it may fall into a bathtub or other water containers.
- Do not run the cord under carpeting. Do not cover the cord with throw rugs, runners or anything else. Arrange the cord away from traffic areas where it could not be tripped over.
- To disconnect the heater, turn the controls to “OFF” before removing the plug from the outlet.
- Do not insert or allow foreign objects to enter any ventilation or exhaust opening, as this may cause an electric shock, fire or damage to the heater.
- To prevent a possible fire, do not block air intakes in any manner.
- A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint or flammable liquids are used or stored.
- Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
- Avoid the use of an extension cord because the extension cord may overheat and cause a fire.
- Always use properly grounded fused and polarized outlets.
- Always use ground fault protection where it is required by electrical codes.
- Always disconnect the power before performing any cleaning, maintenance or relocation of the heater.
- To prevent a possible fire, do not burn wood or other materials in this heater.
- To prevent electric shock or fire, always use a certified electrician, should new circuits or outlets be required.
- When transporting or storing the heater, keep it in a dry place, free from excessive vibration.
UNPACKING AND TESTING APPLIANCE
Carefully remove the appliance from the box. Prior to installing the
appliance, test to make sure the appliance operates properly by plugging the
power supply cord into a conveniently located 120 Volt grounded outlet.
GROUNDING APPLIANCE
This appliance is for use on 120 Volts. The cord has a plug as shown in (A).
An adapter as shown in (C) is available for connecting three-blade grounding
type plugs to two- slot receptacles. The green grounding lug extending from
the adapter must be connected to a permanent ground such as a properly
grounded outlet box. The adapter should not be used if a three-slot grounded
receptacle is available.
To disconnect appliance, turn controls to off, then remove plug from outlet.
LOCATING THE FIREPLACE
Plan where to locate and frame the fireplace. This will save time and money later when you install the fireplace. Before installation consider the following:
- Where the fireplace is located must allow for wall and ceiling clearances (see INSTALLATION)
- Consider a location where the fireplace screen will not be exposed to direct sunlight from windows or doors.
- A 15 ampere, 120 Volt, 60 Hz branch circuit with proper ground must be available at the location.
Preferably a dedicated branch circuit should be provided to avoid circuit breakers to trip of fuses to blow.
102745-XT
Description | Built-in Appliance |
---|---|
Voltage | 120V AC 60Hz |
Watts | 1465W Max |
NO HEATER | 25W |
MOTOR HEATER | 19W |
Appliance Width | 43 5/8” or 110.8 cm |
Appliance Height | 29 1/2” or 75 cm |
Appliance Depth | 12 5/8” or 32.2 cm |
Gross Weight | 94.6lbs or 43kg |
Plug Location | Left side |
Cord Length | 70 7/8” or 180 cm |
Rough Wall Opening Size | 45”× 30“ or 104.3 cm× 76.2 cm |
BTU | 5000 |
This appliance has been tested in accordance with the UL Standard 2021 for
fixed and location dedicated electric room appliances in the United States and
Canada. If you need assistance during installation, please contact your local
dealer.
NOTE: This appliance must be electrically wired and grounded in accordance
with local codes. In the absence of local codes, use the current CSA C22.1
Canadian Electrical Code in Canada or the ANSI/NFPA 70 National Electrical
Code in the United States.
102755-XT
Model Number | Built-in Appliance |
---|---|
Voltage | 120V AC 60Hz |
Watts | 1465 W Max |
NO HEATER | 25W |
MOTOR HEATER | 19W |
Appliance Width | 53 5/8” or 136.2 cm |
Appliance Height | 29 1/2” or 75 cm |
Appliance Depth | 12 5/8” or 32.2 cm |
Gross Weight | 110lbs or 50kg |
Plug Location | Left side |
Cord Length | 70 7/8” or 180 cm |
Rough Wall Opening Size | 55”× 30“ or 139.5 cm×76.2 cm |
BTU | 5000 |
This appliance has been tested in accordance with the UL Standard 2021 for
fixed and location dedicated electric room appliances in the United States and
Canada. If you need assistance during installation, please contact your local
dealer.
NOTE: This appliance must be electrically wired and grounded in
accordance with local codes. In the absence of local codes, use the current
CSA C22.1 Canadian Electrical Code in Canada or the ANSI/NFPA 70 National
Electrical Code in the United States.
102765-XT
Description | Built-in Appliance |
---|---|
Voltage | 120V AC 60Hz |
Watts | 1465W Max |
NO HEATER | 25W |
MOTOR HEATER | 19W |
Appliance Width | 63 5/8” or 148.5 cm |
Appliance Height | 29 1/2” or 75 cm |
Appliance Depth | 12 5/8” or 32.2 cm |
Gross Weight | 127.6lbs or 58kg |
Plug Location | Left side |
Cord Length | 70 7/8” or 180 cm |
Rough Wall Opening Size | 65”× 30“ or 165.1 cm× 76.2 cm |
BTU | 5000 |
This appliance has been tested in accordance with the UL Standard 2021 for
fixed and location dedicated electric room appliances in the United States and
Canada. If you need assistance during installation, please contact your local
dealer.
NOTE: This appliance must be electrically wired and grounded in
accordance with local codes. In the absence of local codes, use the current
CSA C22.1 Canadian Electrical Code in Canada or the ANSI/NFPA 70 National
Electrical Code in the United States.
SAFETY DRILL SCREW AREA
There is a safety drill screw area as show below.
Please make sure that the fix screws are in this area.
HARD- WIRE INSTALLATION
Turn off the appliance completely and let cool before servicing. Only a
qualified service person should service and repair this electric appliance.
If it is necessary to hard wire this appliance, a qualified electrician must
remove the cord connection, and wire the appliance directly to the household
wiring.
This appliance must be electrically connected and grounded in accordance with
local codes, if hard wired. In the absence of local codes, use the current CSA
C22.1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI/NFPA 70 NATIONAL
ELECTRICAL CODE in the United States.
- Remove the cover plate from the left side of the appliance by removing the two screws, as shown below. Unscrew and remove power cord.
- Attach the wiring to the junction block. Please make sure the live wire goes into the “L”, the neutral wire into “N” and the ground wire into “G”.
- Put the plate back and screw back.
FOR BATHROOM USE
If this unit is installed in a bathroom it must be protected by a GIF
receptacle or circuit. If receptacle is used it must be readily accessible.
To prevent electric shock, please be aware that this unit is an electrical
appliance that is NOT watertight and must be installed as to prevent water
from entering unit. This must be installed away from shows, tubs, etc. Never
locate fireplace where it may fall into a bathtub or other water container.
All wiring connections to line power shall be in accordance with local
building code requirements.
Inquires about local codes and regulations must be done prior to installation.
OUTDOOR INSTALLATIONS
The 102745-XT, 102755-XT and 102765-XT electric fireplaces are suitable for installation in outdoor areas protected from direct water impingement. In addition to maintaining the listed mantel and combustibles clearances, a rain protection overhang factor of 1/2 shall be constructed to the front and to each side of the installed appliance. See illustration below. All wiring connections to line power shall be in accordance with local building code requirements. Inquires about local codes and regulations must be done prior to installation.
The overhang (A) must extend at least 1/2 the roof-line height (B).
Height is measured from the base of the fireplace.
For example: if the roof-line (B) is 8’ above the base of the fireplace, the
overhang (A) must be at least 4’.
INSTALLATION
The 102745-XT, 102755-XT and 102765-XT models are designed to be built-in.
These units allow for the finishing material (drywall, stone, tile, etc) to be
built right down to the glass edge. However, that application is not always
desirable or available so the surround could be used as an alternate finish
option.
Important note: The optional surround is not firmly attached and can be
removed from the unit by simply pulling it off. It is recommended that two
people remove the surround.
The rough wall opening size of the fireplace:
| W(")| D(")| H(")
---|---|---|---
102745-XT| 45| 12 1/2| 30
102755-XT| 55| 12 1/2| 30
102765-XT| 65| 12 1/2| 30
-
Take out the unit from the box. Please do the pre-test before you install the fireplace. Pull out the optional trim from the unit as shows below.
-
Remove the framing plates from the unit
-
Re-fix the framing plates to the unit as the picture shows
-
Bend up the framing plates.
-
Put the unit into the opening.
-
Drive the mounting screws into the framing plates on the unit and the wall studs.
-
After checking that the fireplace operates properly, cover the glass panel with protective plastic bag and install plywood or drywall.
IMPORTANT NOTE: IF YOU WANT TO USE THE SUPPLIED SURROUND the thickness of the wall finish can only be 1”. -
Decorate the plywood or drywall with glazed tile, wallpaper, etc.
-
Put back the trim that you’ve removed from the unit at STEP 1.
Media Options
The 102745-XT, 102755-XT and 102765-XT are shipped with two mixture media
shows below: the Canyon brown and Ocean blue. Consumers may purchase optional
decorative media if they choose.
See dealer for more details.
FIRE GLASS MEDIA-LOG INSTALLATION
-
Take off the front clear glass. There is a bracket that holds the front glass as shows below.
Unscrew the screw to take off the bracket. Turn around the bracket and insert it into the gap to hook and pull out the glass. -
Install the fire glass media. Pour the fire glass media into the try. Feel free to use any combination of fire glass media that you find most appealing.
-
Put back the front glass after you finish the fire glass decoration.
OPERATION
The fireplace can be operated either by the switches located on the left
bottom of the fireplace unit or by supplied remote control.
Plug the fireplace into a 15 Amp wall socket.
MANUAL OPERATION
-
The main power ON/OFF switch in position O, the fireplace is OFF.
-
When main power ON/OFF switch is at position I, the fireplace is ready to use.
-
Press the button repeatedly to set the heater to desired heat setting. The heater indicator LED will glow which shows the current heater settings.
a) RED 1465W HEAT OUTPUT
b) BLUE 750W HEAT OUTPUT
c) PURPLE AUTO MODE
AUTO MODE
Under this mode the heater will automatically turn ON at high heat setting 1465W heat output when the room temperature drops below 22℃(72 ℉ ). When the room temperature is between 22-25℃(72-77℉) the heater output will switch to low heat setting 750W. When the room temperature goes above 25℃(77℉) the heater will be turned off and the cycle will continue. The LED indicator will be PURPLE in colour under this mode. -
Flame effect: Press the button marked to adjust the flame brightness. The flame brightness will cycle through –Low-Medium-High -OFF.
-
Mood light effect: Press the button marked to change the mood light colour.
NOTE: If operated at the Low heat setting, the fireplace will not provide
as much heat output as in the High heat setting, however the low setting will
not require as much electrical power to operate.
To avoid overloading a circuit, do not plug the fireplace into a circuit that
already has other appliances working. When the fireplace is not in use switch
off and unplug.
SAFETY CUT-OFF
- This appliance is fitted with a safety cut-off which will operate if the fireplace overheats (eg. Due to blocked air vents). For safety reasons, the fireplace will NOT automatically reset.
- To reset the appliance, disconnect the appliance from the main supply for at least 10 minutes.
Reconnect the supply to the main and switch on the appliance.
REMOTE CONTROL OPERATION
For remote to function make sure the heater is plugged in and main power
switch located on the bottom left hand side is at position I.
When operating the remote make sure you point the remote to the centre of the
fireplace and make sure each time you press the button the buzzer inside the
unit will beep once. It takes some time for the receiver to respond to the
transmitter. Do not PRESS the buttons more than once within two seconds for
correct operation.
Power on button: The power-on button at top left corner of the remote is the
main ON/OFF power button. This will turn off all the functions and the
fireplace will be in standby mode.
DISPLAY ON/OFF button: Switching the fireplace flame and tray light ON/OFF. It
has functions of setting memory.
DISPLAY BLUE button: Adjust the blue color brightness of flame and tray.
DISPLAY YELLOW button: Adjust the yellow color brightness of flame and tray.
DISPLAY ORANGE button: Adjust the orange color brightness of flame and tray.
MOOD LIGHT ON/OFF button: Switching the mood light ON/OFF.
ADJUST button: Switching the color of the mood light.
FLASH button: Switches the mood light into flash mode, this cycles through all
mood light colors.
HEATER ON/OFF button: Switching the heater ON/OFF. It has functions of setting
memory.
HIGH button: Press the high button to switch the heater to high heat setting
1465W.
LOW button: Press the low button to switch the heater to low heat setting
750W.
TEMP. button: Press the TEMP. button to switch the heater to AUTO mode. Under
this mode the heater will operate in similar way as explained above for the
manual operation.
INSTALLING WALL THERMOSTAT
WALL THERMOSTAT WIRING DIAGRAMS
Wire the wall thermostat prior to installing the fireplace.
WALL THERMOSTAT WIRING(24 VAC)
Install Wall Thermostat per instructions provided with kit and per the
following information:
- Turn off circuit breaker.
- Remove cover plate located on the left side of appliance.
- Pull the wire out and cut the inside thermostat. Connect the wires to the wall thermostat as shown below. Follow instructions provided with wall switch kit.
REPLACEMENT PARTS
This list contains replacement parts
NO | DESCRIPTION | QTY. | |
---|---|---|---|
102745-XT | 102755-XT | 102765-XT | |
1 | 602030C | 602030C | 602030C |
2 | |||
3 | 10104010 | SWITCH | 1 |
4 | 601036 | CONTROL PANEL | 1 |
5 | 601092C | CIRCUIT BOARD | 1 |
6 | 10101225 | FLAME MOTOR | 2 |
7 | 3134504 | 3136504 | 3138504 |
8 | 601136B | LED STRIP | 4/6/8 |
601137B | 2/2/2 | ||
9 | 10203015 | ADJUSTABLE FOOT | 4 |
10 | 10701264 | 10701266 | 10701268 |
PLASTIC | 1 | ||
11 | 3057012 | GLASS BRACKET LH | 1 |
12 | 3057013 | GLASS BRACKET RH | 1 |
13 | 10702190 | 10702192 | 10702194 |
14 | 3111017 | MEDIA HOLD BRACKET | 2 |
15 | 3057016 | FRONT GLASS BRACKET | 2 |
16 | |||
17 | 10701256 | 10701258 | 10701260 |
18 | 3139501 | BLACK STEEL SURROUND | 1 |
19 | 10105063 | REMOTE | 1 |
EXPLODED VIEW
TROUBLE SHOOTING
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|---|---|
Dim or no flame | Flame LED’s are burnt out | Inspect the LED’s and replace them |
if necessary.
Ember bed is not glowing or dimming| Ember LED’s are burnt out| Inspect the
ember bed LED’s and replace them if necessary.
Appliance turns off and will not turn on| Appliance has overheated and safety
device has caused the thermal switch to disconnect| Turn off the main switch,
allow appliance to cool for 10 minutes, then turn it on.
House tripped circuit breaker has| Reset house circuit breaker.
Appliance’s fuse has blown| Replace the fuse.
Appliance will not come on when switch is flipped to ON| Appliance is not
plugged into an electrical outlet| Check plug and plug in.
Appliance has overheated and safety device has caused the thermal switch to
disconnect| Turn off the main switch, allow appliance to cool for 10 minutes,
then turn it on.
Circuit board is burnt out| Inspect the circuit board and replace it if
necessary.
No warm air coming out of appliance| Heater is burnt out| Inspect the burner
and heater assembly and replace it if necessary.
Flame sputters| Flame motor is defective.| Call a qualified service technician
and replace flame motor.
Remote Control does not work.| Low batteries.
Unit switch in “O” position.| Replace AAA batteries in control.
Turn the switch in “I” position. remote
Flame is fixed.| Wiring may be loose or the flame motor may be defective.|
SERVICE HISTORY
This heater must be serviced annually depending on usage.
Date| Dealer Name| Service technician Name| Service
Performed| Special Concerns
---|---|---|---|---
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
| | | |
WARRANTY
Remii Electric Fireplaces (“Remii”) warrants that your newly purchased Remii
electric fireplace is free from manufacturing and material defects for a
period of two (2) years from the date of the first purchase, subject to the
conditions and limitations contained below.
Warranty Application & Exclusions
This limited warranty applies to your newly purchased Remii electric
fireplace; the limited warranty’s application is limited to purchases made in
any province of Canada or in any of the 52 States of the United States of
America, including the District of Columbia. Only the original purchaser of
the product is eligible for coverage under this limited warranty; the
warranty is not transferable.
Products excluded from this limited warranty
Light bulbs are not covered by this limited warranty and are the sole
responsibility of the owner/purchaser. Remii does not cover service or labor
charges.
Warranty Coverage and Term
Products covered by this limited warranty have been tested and inspected prior
to shipment and, subject to the provisions of this warranty, Remii warrants
such products to be free from defects in material and workmanship for a
period of two (2) years from the date of the first purchase of such products.
The limited two (2) year warranty period for products also applies to any
implied warranties that may exist under applicable law. Some jurisdictions do
not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to the purchaser.
All other warranties—expressed or implied—with respect to the product, its
components and accessories or any obligation/liabilities on the part of Remii
are hereby expressly excluded.
Limitations to Coverage Under Limited Warranty
This limited warranty does not apply to products that have been repaired,
or otherwise altered. This limited warranty further does not apply to defects
resulting from misuse, abuse, accident, neglect, incorrect installation,
improper maintenance or handling, or operation with an incorrect power source.
Products made by other manufacturers, sold with the product or thereafter,
are not covered by this limited warranty. The use of unauthorized components
will render this warranty null and void.
Outdoor Rated Units
All units that are installed outdoors or in moisture intense conditions must
use the stainless steel cover/and or be installed with appropriate shelter.
Proof of purchase of the cover and/or shelter is required for any warranty
claims.
Defects
Defects must be brought to the attention of the selling dealer. Please have
your proof of purchase, catalogue/model and serial numbers available when
contacting dealer; any and all service under the limited warranty requires a
proof of purchase of the product. Should a product or part covered by this
limited warranty be proven to be defective, in material or workmanship, and
during the two (2) year limited warranty period, Remii will replace such
defective product or part without charge. If Remii is unable to replace such
part, or if replacement is not commercially practicable or cannot be timely
done, in its sole discretion Remii may, in lieu of replacement, choose to
refund the purchase price for such product or part. Remii does not cover
labor or service charges to replace said parts.
Limitations
In no event will Remii, including without limitation any of its directors,
officers, shareholders, employees, consultants, agents, heirs, executors,
administrators and assigns, be liable to the purchaser or any third party,
whether in contract, in tort, or on any other basis for any indirect, special,
punitive, exemplary, consequential, or incidental loss, cost or damage
arising out of or in connection with the sale, maintenance, use or inability
to use the product, even if Remii, including without limitation any of its
directors, officers, shareholders, employees, consultants, agents, heirs,
executors, administrators and assigns, have been advised of the possibility of
such losses, costs or damages, or if such losses, costs or damages are
foreseeable. In no event will Remii, including without limitation any of its
directors, officers, shareholders, employees, consultants, agents, heirs,
executors, administrators and assigns, be liable for any direct losses, costs
or damages that exceed the purchase price of the product.
Some jurisdictions do not allow the exclusion or limitation of incidental or
consequential damages, so the above limitation or exclusion may not apply to
the purchaser.
Application of Provincial and State Law
This limited warranty gives you specific legal rights, and you may also have
other rights which vary from jurisdiction to jurisdiction. The provisions of
the United Nations Convention on Contracts for the Sale of Goods shall not
apply to this limited warranty or the sale of products covered by this limited
warranty.
General
Remii reserves the right to make changes at any time without notice, in
design, material, specifications, prices and the right to discontinue styles
and products.
Remii Electric Fireplaces
502-1027 Davie Street
Vancouver, BC V6E4L2
Documents / Resources
|
Remii 102745-XT 45 In Extra Tall Deep Built In Electric
Fireplace
[pdf] Instruction Manual
102745-XT 45 In Extra Tall Deep Built In Electric Fireplace, 102745-XT, 45 In
Extra Tall Deep Built In Electric Fireplace, Built In Electric Fireplace,
Electric Fireplace, Fireplace
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>