Yale WGA5.8 Digital Door Lock User Manual
- June 9, 2024
- Yale
Table of Contents
- Yale WGA5.8 Digital Door Lock
- WHAT’S INCLUDE
- Preparing Door and Keypad Escutcheon
- INSTALLATION
- Programming Instructions
- Resetting Lock to Factory Default
- Enrolling Lock In Z-Wave Plus Network
- Definitions
- Feature Programming Through Menu Mode Using Master PIN code
- Programming Troubleshooting
- FCC
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Yale WGA5.8 Digital Door Lock
WHAT’S INCLUDE
Preparing Door and Keypad Escutcheon
INSTALLATION
Programming Instructions
Master PIN Code must be created before any further programming. Max User Codes
250 in network
Warning: Changes or modifications to this device, not expressly approved
by ASSA ABLOY Residential Group could void the user’s authority to operate the
equipment.
Changing Master PIN Code
Creating User PIN Codes
Unlocking Door with PIN Code
Code Chart duplicate if necessary
Resetting Lock to Factory Default
When lock is reset to factory defaults all user codes (including the Master PIN code) are deleted and all programming features are reset to original default settings (see “Factory Default Settings”).
- Remove the battery cover.
- Remove the batteries.
- While pressing the reset button (minimum of 3 seconds) reinstall batteries. Release reset button.
- Replace battery cover.
Upon reset, Master Code creation is the only option available and must be
performed prior to any other programming of the lock.
NOTE: After setting the Master Code, press any key to complete handing of
the lock.
Enrolling Lock In Z-Wave Plus Network
Your network controller first needs to be in enrollment or exclusion mode for the lock to be enrolled or removed from network.
Once you put the controller in the enrollment or exclusion mode, the lock can be enrolled or removed in the Z-Wave Plus Plus network by pressing the ( button.
To enroll lock using the button option
- Remove the battery cover.
- Press ( button and hold until unit beeps two (2) times.
- Release button and network joining automatically begins.
- Replace battery cover.
To remove lock using the ebutton option:
- Remove the battery cover.
- Press o button and hold until unit beeps five (5) times.
- Release button and network removal automatically begins.
- Replace battery cover.
Definitions
- All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user (except Master) PIN code access. When attempting to enter a code while the unit is in Lockout, the lock rapidly beeps 5 times.
- Audio Mode: Choosing Disable (3) in Audio mode shuts off the code confirmation tone play-back for use in quiet areas. Audio mode is enabled or disabled through feature programming by the Master code.
- Automatic Re-lock Time: After a successful code entry or manual unlock with the key, the lock will automatically re-lock after each unlock in an effort to keep your home secure. This feature is optional, and can be turned off. In the ON mode, the lock will automatically re-lock after thirty (30) seconds.
- Low Battery: When battery power is low, the Low Battery Warning Indicator flashes RED. If battery power is completely lost, use the 9Volt battery override. To use the 9V battery override apply 9V battery, in either direction, to terminals below the keypad for backup power option. Wake up the lock and enter your pin code to unlock the door.
- Master PIN Code: The Master PIN code is used for programming and for feature settings. It must be created prior to programming the lock. The Master code will also operate (unlock/lock) the lock.
- Network Setting: This setting is available through the wireless button on the interior escutcheonand allows the lock to connect with a network controller.
- One Touch Locking: When the latch is retracted, activating the keypad will extend the latch (during Automatic Re-lock duration or when Automatic Re-lock is disabled).
- Shutdown Time: The unit will shutdown (flashing keypad) for sixty (60) seconds and not allow operation after the wrong code entry limit has been met.
- Tamper Alert: Audible alarm sounds if attempting to forcibly remove outside lock from door.
- User PIN Code: The User code operates the lock. Maximum number of user codes is 250 in network.
- Wrong Code Entry Limit: After five (5) unsuccessful attempts at entering a valid PIN code, the unit will shut down and not allow operation for sixty (60) seconds.
Feature Programming Through Menu Mode Using Master PIN code
- Wake the lock by pressing the key.
- Enter the 4-8 digit Master PIN code followed by the key.
- Enter digit corresponding to the function to be performed followed by the key.
Factory Settings
The Master PIN cOde must be registered prior to any other programming of the lock.
Programming Troubleshooting
FCC
FCC ID: 2ABFG-YRIZW2USPB2
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO
THE FOLLOWING TWO CONDITIONS.
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE
UNDESIRED OPERATION.
Industry Canada:
IC: 11626A-YRIZW2USPB2
Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio
transmitter may only operate using an antenna of a type and maximum (or
lesser) gain approved for the transmitter by Industry Canada. To reduce
potential radio interference to other users, the antenna type and its gain
should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that necessary for successful communication.
Section 7.1.3 of RSS-GEN THIS Device complies With Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device.
This radio transmitter 6982A-YRHCPZWOFM has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
FCC and IC RF Radiation Exposure Statement:
This equipment complies with FCC and IC RF Radiation exposure limits set forth
for an uncontrolled environment, This device and its antenna must not be co-
located or operating in conjunction with any other antenna or transmitter.
This equipment should be installed and operated with a minimum distance of 20
cm between the radiator and our body.
Yale Locks & Hardware
Product Support Tel 1-855-213-5841
www.yalehome.com
Yale® and Yale Real Living® are registered trademarks of ASSA ABLOY Residential Group. Other products’ brand names may be trademarks or registered trademarks of their respective owners and are mentioned for reference purposes only. Copyright 2019. Al rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Residential Group is prohibited.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>