Introduction
The RHT100 provides extreme accuracy when measuring the moisture and air temperature being expelled from an A/C system. The RHT100 makes system diagnostics easier and more reliable.
Safety
- Do not use the measuring instrument and probes to measure on or near live parts.
- Never store the measuring instrument/measuring cells together with solvents and do not use any desiccants.
- Do not use leaky or damaged batteries.
- Use only specified batteries. (AA Batteries)
- Battery operating temperatures may vary by manufacturer. The batteries supplied with this unit are for storage and operating between 32°F – 104°F (0°C – 40°C)
- Operate the measuring instrument only within the parameters specified in this user manual.
- Do not expose handles and feed lines to temperatures in excess of 70°C unless they are expressly permitted for higher temperatures. Temperatures given on probes relate only to the measuring range of the sensors.
- Batteries must only be changed in a non-hazardous area.
- Dispose of batteries in accordance with any applicable local laws and regualtions.
- Do not dispose of the product or battery in a fire or heat above 100°C.
WARNING: Do NOT touch insert any objects into the sensor port. Doing so may permanently damage the sensor.
WARNING: Do NOT remove the sensor port housing.
Package Contents
(1) RHT100 Relative Humidity Temperature Gauge
(1) Digital Gauge Carrying Case
(2) AA Batteries
(1) Quick Start Guide
Display
- Battery Level Indicator
- Hold Indicator (Flashing)
- Auto Power Off Indicator
- Bluetooth Indicator
- Relative Humidity
- Ambient Temperature
- Wet Bulb
- Dew Point
- Units
- Separation Lines (Flashing)
Temperature Units: Fahrenheit/ Celcius
Controls
PRESS a button for the “press” function
HOLD a button for 2 seconds for the “Hold” function
Controls (cont.)
Power
– Quick Press
-
Gauge Power On
– Hold -
Gauge Power Off
Backlight/Units
– Quick Press
-
Backlight On/Off When the backlight is toggled on, the backlight stays on for 1 minute.
– 2 Seconds Hold -
Units Selection Pressing and holding the backlight button for 2 seconds toggles the temperature units.
– Backlight + Power -
Bluetooth Toggle On/Off
Hold
– Quick Press
-
Hold Values On/Off
– Hold + Power -
Auto Power Off Toggle On/Off
Using the RHT100
- Power the gauge on.
- Connect the gauge via Bluetooth to the Appion Central App (optional) 3. Hold or use the goose neck to hook the the humidity/temperature sensor directly in the air flow-path of the system being tested. 4. Monitor the results via the backlit display or the Appion Central App.
Appion Central™ Bluetooth Operation
Note: Bluetooth communication requires a compatible device running the Appion Central’ App. Development of the Appion Central’ App is ongoing, and any infor-mation presented in this manual about the Appion CentalTM App may not be up to data Visit Appion-Tools.com or your device’s App Store for the latest Appion CentralTM App and additional information.
- With the RHT100 powered on, press and hold the “Backlight/Units” button AND the “Power” button for a few seconds, until the Bluetooth symbol begins flash-ing on the RHT100 screen.
- In the Appion CentralTM App, “Scan” for devices, and connect as shown in the Appion Central’ App. When using multiple Appion gauges, it may be easiest to connect all of the gauges first, then disconnect if needed.
- If the connection is lost due to exceeding the Blue-tooth range, or due to loss of power, repeat Step 1, then “Reconnect” the RHT100 through the Appion CentralTM App interface.
Note: Bluetooth range may vary due to obstructions or interference. The Appion Central’ App will indicate when communication is lost.
Note: The RHT100 will continue to operate normally even if Bluetooth communication is lost.
Appion Central™ App
Scan to dowload app and access user guide.
Specifications
Weight: 114 g / 4.02 oz (without batteries)
Gauge Body Dimensions: 260 x 48.25 x 25.4 mm /10.23 x 1.9 x 1 in
Flexible Probe Dimensions: Length:107 mm / 4.2 in Diameter: 9.75 mm / .38
in
Gauge Operating Temperature: -20 °C to 55 °C / -4 °F to 131 °F (limited
by battery performance)
Storage Temperature: -20 °C to 60 °C / -4 °F to 140 °F (without
batteries)
Battery Type: 2x AA
Battery Life: Bluetooth On: 500 hours at 25 °C / 500 hours at 77 °F
Bluetooth Off. TBD
Wireless Range: TBD (line of sight)
Auto Power Off Time: 15 minutes (Selectable On/Off)
Specifications (cont )
Sensor Response Time:
Temperature: 10 °C in 1 Second (0 °C to 70 °C) /18 °F in 1 Second (32 °F to
158 °F) Relative Humidity: 20% RH 3-5 Seconds (40% to 80% RH at 25 °C) / 20%
RH 3-5 Seconds (40% to 80% RH at 77 °F)
Sensor Operating Range:
Temperature: -40 °C – 100 °C / -40 °F – 212 °F Relative Humidity: 0% – 100%
RH
Resolution:
Temperature: .1 °C / .1 °F Relative Humidity: 1% RH
Temperature Sensor Accuracy:
Low Temp Range: +/-.5 °C (-40 °C to 0 °C) / +/-.9 °F (-40 °F to 32 °F)
Mid Temp Range: +/-.2 °C (0° C to 70 °C) / +/- .36 °F (32 °F to 158 °F)
High Temp Range: +/-.5 °C (70 °C to 100 °C) / +/-.9 °F (158 °F to 212 °F)
Relative Humidity Sensor Accuracy:
+/- 4.5% RH (<10% RH at 25 °C) / +/- 4.5% RH (<10% RH at 77 °F)
+/- 3.5% RH (10% to 20% RH at 25 °C) / +/- 3.5% RH (10% to 20% RH at 77 °F)
+/- 2.5% RH (20% to 80% RH at 25 °C) / +/- 2.5% RH (20% to 80% RH at 77 °F)
+/- 3.5% RH (>80% RH at 25 °C) / +/- 3.5% RH (>80% RH at 77 °F)
Regulatory Information
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must
accept any interference received, including the interference that may cause
undesired operation.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communica-tions.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which may be determined by turning the
equipment off and on, the user is en-couraged to try to connect the
interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC RF radiation expo-sure limits set forth for
an uncontrolled environment. This transmitter must not be co-located or
operating in conjunction with any other antenna or transmitter.
FCC Caution
To assure continued compliance, any changes or modifications not expressly
approved by the party responsible for compliance could void the user’s
authority to operate this equipment.
Industry Canada Radio Equipment
This device complies with Industry Canada license exempt RSS-247 standard.
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any inter-ference that may
cause undesired operation of the device.
Warranty Information
Appion Inc. (Hereinafter Appion) warrants that this equipment will, under
normal and anticipated use, be free from defects in materials and workmanship
for a period of one (1) year from the date of purchase by Purchaser from an
Appion-authorized distributor. The complete Manufacturer’s Limited Warranty is
available online at AppionTools.com.
All warranty services must receive Appion Factory Authorization and an RGA
number prior to any action. Contact your local Appion authorized distributor
to obtain the RGA number and shipping instructions. To help us provide the
best service, be sure to have the following information available:
- Serial number of the equipment
- Purchase date of the defective unit
- A detailed description of the problem
Appion offers technical troubleshooting customer support for the lifetime of every product. Regardless of your warranty status, you can always contact us for assistance. Our website includes additional technical information that can help you experience the fullest potential of our products, making tour job quicker and easier.
Appion RHT100 Warranty Registration Card
Please complete this card and return it within 10 days of purchase with a copy
of your sales receipt.
Your Name| Your Company
Street Address| Phone Number
City| State Zip
Email Address| Serial Number
Place of Purchase| Date of Purchase
How did you learn about our products?
(Please only check one)
Wholesaler
Recommended By:
Magazine
Newspaper Ad
Internet| Please select your primary line of business.
(Check all that apply)
Automotive
Commercial
Residential
Service
Installation
Register by Mail:
Appion Inc.
2800 South Tejon Street Englewood, CO 80110 USA
Register by Email or Fax:
1.Scan this page AND a copy of your sales receipt.
2.Email to: Sales@AppionTools.com or Fax this
page and your sales receipt to:
1-303-937-1599|
What features most interested you?
(Check all that apply)
High Production
Low Cost
Low Maintenance
Portability
Ease of Use
Other: ……………………
Scan for Product Registration
QR Code Index
|
---|---
Appion Central App Download| Product Registration
Appion Inc.
2800 South Tejon St.
Englewood, CO 80110 USA
Tel: 1-303-937-1580
Fax: 1-303-937-1599
AppionTools.com
Sales@AppionTools.com
Support@AppionTools.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>