STILLCLEan H-45NT Aqueous Parts Washer Instruction Manual
- June 9, 2024
- STILLCLEan
Table of Contents
STILLCLEan H-45NT Aqueous Parts Washer
INSTRUCTION MANUAL FOR EQUIPMENT AND CHEMICAL MAINTENANCE
DO NOT PLUG THE WASHER IN UNTIL IT IS FULL OF WATER
FEATURES AND SPECIFICATIONS:
OSI Environmental, Inc. – 1000 Lund Blvd, Anoka, MN 55303 Phone : 800-628-7657 / www.osienv.com /www.stillclean.com
HYDRA 45NT MOBILE PARTS WASHER
- Tank: Hydra 45Molded HDPEPlastic Tank Capacity:45 gallons.
- Hydra45electrical requirements 120 Volts AC, 12 Amps. Operates on a standard industrial 20 amp. 120 volt circuit.
- The heater is 1000 watts and constructed of 304 stainless steel.The heater has an integratedlevel float and internalpreset temperature and over temperature controls with an operating range of 113 to 117 degrees F.
- The sink includes a400 micron 4” diameter bag filter in the sink drain.Other filter ratings are available.The bag filter can be cleaned or replaced.
- The 300 gph pump includes a debris screen.
- GFCI cord plug.a preset manual temperature control with overtemperature and low level protection.
- The washer has 4 multi directional castersfor ease of movement.
- Complete sytem weight 75 Lbs dry weight.
- Sink dimensions: ID 36” L to R, 21” F to B, 40” high, 8” Sink Depth.
- Machine dimensions: OD 38.25” L to R, 32” F to B, 40” Floor to top of Sink.
Caution:
- Read and understand the manual before using the washer.
- This unit is designed to be used with water based cleaners. DO NOT use with any flammable/combustible cleaning chemicals.Including but not limited to mineral spirits, petrochemical solvents or any other petroleum or alcohol based chemicals. Doing so will create a hazardous situation, which could result in serious injury, death and property and equipment damage.
- Heated waterbased cleaners will evaporate water with use, check the solution level reguarly to insure proper function of the parts washer. Closing the lid and not leaving the pump running when the system is not in use can minimize evaporation.
- Use care not to overfill the unit, proper solution depth is approximately 22” up from the bottom of the tank.
- Unplug or lock out the unit before performing any service.
- Do NOT place hot parts in the sink.
- Do NOT use the washer if damaged or safety mechanisms are in operable. Have the unit serviced before continuing operation.
HYDRA 45NT MOBILE PARTS WASHER
- If an extension cord is needed to operate the equipment, care must be taken to assure the proper rating. Do NOT use an extension cord that is underrated.
- In case of malfunction or emergency, unplug the unit and contact a service person.
- Proper solution level must be maintained for heater and pump operation. Low solution level may cause heater or pump failure.
- Maintain cleaning chemicals and clean system regularly to avoid build up of sludges and oils in the system that may interfere with the heater/pump operation.
- This unit is designed for indoor use only.
- Personal Protective Equipment must be worn such as but not limited to safety glasses and gloves. See chemical SDS’s for recommendations.
Replacement Parts:
Part Number| Description| Qty.|
---|---|---|---
2009P| Wash pump, fractional HP, 120 VAC| | 1
PW-A-1KW/120V| 1KW / 120 VAC Heater| | 1
PW-3300| Flow Thru Wash Brush| | 1
H30SO| H45 Sink| | 1
H34.0047| Aluminum sink mount| | 1
H34.0030| Sink Latch| | 1
H30NT-PC| H45 Plastic Sink Cover| | 1
H4. Tanks| H45 Tank| | 1
Filter Bag| 4” 200 Micron| | 1
H345.0003| Metal drain cover/strainer| | 1
H34.0034| Electrical Box, 2 switch, duplex receptacle| | 1
H34.0019| Receptacle, two gang 120 VAC / 15 amp| | 1
H345.0035| Lighted ON/OFF Switch 125VAC / 20 amp| | 2
H345.0001| GFCI Cord plug 120 VAC / 15 amp| | 1
H34.0017| Male cord plug male, yellow| | 1
H34.0046| Cord whip heater, black, male 4 ft. 14/3| | 1
H34.0020| Casters, no brakes| | 4
H345.0004| LOC Line Flex ½” tubing| | 12”
H345.0005| LOC Line ½” valve| | 1
H345.0006| LOC Line ½” nossle| | 1
H345.0007| ½” poly pro T| | 1
Replacement Parts Continued
Part Number| Description| Qty.|
---|---|---|---
H345.0010| Stainless ½” NPT x 1/2” NPT Valve| | 1
H345.0015| Cam lock fitting female to male barb| | 1
H345.0016| Cam lock fitting male to female| | 1
Warranty Statement
Term of warranty shall be one year to original owner from invoice date. OSI
shall replace for one year those parts returned to the factory, which upon
inspection by the company are determined to be defective. All repairs must be
made with authorized replacement parts to be covered by warranty. Parts must
be returned freight prepaid within 15 days of receipt of R.G.A.
R.G.A. must appear on all returned goods.
OSI Environmental, Inc. – 1000 Lund Blvd, Anoka, MN 55303 Phone :
800-628-7657 /
www.osienv.com
/www.stillclean.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>