GENERAL INFORMATION
Why is the SMART Position Sensor smart? SMART means that this is a sensor that
can essentially think for itself. The SMART Position Sensor has the ability to
self-calibrate because it uses a patented combination of an ASIC (Application-
Specific Integrated Circuit) and an array of MR (magnetoresistive) sensors to
accurately and reliably determine the position of a magnet attached to a
moving object (e.g., elevator, valve, machinery, etc.) so that the object’s
position can be determined.
The MR array measures the output of the MR sensors mounted along the magnet’s
direction of travel. The output and the MR sensor sequence determine the
nearest pair of MR sensors to the center of the magnet location. The output of
these two MR sensors is then used to determine the position of the magnet
between them. With this sensor, Honeywell has utilized MR technology through
the ASIC at a level never before accomplished.
MOUNTING AND WIRING INFORMATION (see Fig. 2)
- Locate sensor and magnet in desired position. Ensure:
- Air gap between sensor and magnet does not exceed that given in Table 1.
- Alignment of magnet along length of sensor does not exceed 2,0 ±2,5 mm [0.078 ±0.098 in] from the center line of each component.
- Mount sensor:
- Drill two holes, one for each mounting ear.
- Secure sensor using two ¼-20 or M6 screws through each mounting ear.
- Torque screws to 6 N m to 10 N m [53.1 in lb to 88.5 in lb].
- Mount magnet (Does not apply to 35 mm version.):
- Drill two holes:
- One for the single mounting ear.
- One at 10,25 ±0.10 mm [0.403 ±0.004] dia., and at least 3 mm [0.118 in] deep, for the mounting dog (helps stabilize magnet).
- While ensuring the mounting dog is seated in its hole, secure magnet using one ¼-20 or M6 screw through the mounting ear.
- Torque screws to 6 N m to 10 N m [53.1 in lb to 88.5 in lb].
- Wire sensor according to the lead colors given in Table 1.
(Does not apply to 35 mm version.)
SPECIFICATIONS
NOTICE
- Ferrous metal within a 100 mm [3.9 in] radius of the magnet actuator may affect sensor performance.
- Always use fresh, non-magnetic stainless steel washers when mounting the sensor.
FIGURE 1. SPS-L035-LATS MOUNTING DIMENSIONS (FOR REFERENCE ONLY: MM) AND SENSOR OUTPUT PERFORMANCE GRAPH FIGURE 3. SPS-L225-HALS MOUNTING DIMENSIONS (FOR REFERENCE ONLY: MM) AND SENSOR OUTPUT PERFORMANCE GRAPH FIGURE 4. SPS-L225-HDLS MOUNTING DIMENSIONS (FOR REFERENCE ONLY: MM) AND SENSOR OUTPUT PERFORMANCE GRAPH
WARNING PERSONAL INJURY
DO NOT USE these products as safety or emergency stop devices or in any other
application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious
injury.
WARNING
MISUSE OF DOCUMENTATION
- The information presented in this product sheet is for reference only. Do not use this document as a product installation guide.
- Complete installation, operation, and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
FOR MORE INFORMATION
Honeywell Advanced Sensing Technologies services its customers through a
worldwide network of sales offices and distributors. For application
assistance, current specifications, pricing or the nearest Authorized
Distributor, visit our website or call:
USA/Canada +1 302 613 4491
Latin America +1 305 805 8188
Europe +44 1344 238258
Japan +81 (0) 3-6730-7152
Singapore +65 6355 2828
Greater China +86 4006396841
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective
materials and faulty workmanship during the applicable warranty period.
Honeywell’s standard product warranty applies unless agreed to otherwise by
Honeywell in writing; please refer to your order acknowledgment or consult
your local sales office for specific warranty details. If warranted goods are
returned to Honeywell during the period of coverage, Honeywell will repair or
replace, at its option, without charge those items that Honeywell, in its sole
discretion, finds defective. The foregoing is buyer’s sole remedy and is in
lieu of all other warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no event shall
Honeywell be liable for consequential, special, or indirect damages.
While Honeywell may provide application assistance personally, through our
literature and the Honeywell web site, it is buyer’s sole responsibility to
determine the suitability of the product in the application. Specifications
may change without notice. The information we supply is believed to be
accurate and reliable as of this writing. However, Honeywell assumes no
responsibility for its use.
Honeywell
Advanced Sensing Technologies 830 East Arapaho Road Richardson, TX 75081
sps.honeywell.com/ast
32305127-B-EN | B | 12/12
© 2021 Honeywell International Inc. All rights reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>