Sage JSG-S006 BLE Sensor User Manual
- June 9, 2024
- Sage
Table of Contents
User manual for
BLE Sensor
JSG-S006
JSG-S006 BLE Sensor
General
Purpose of this Guide is to install the devices and to describe the related
function how to use them for the Dealers and Mechanic of contracting company.
The functions are
necessary to operate the initial setup and maintain an appropriate usage of
the App.
FCC Statement:
Any changes or modifications not expressly approved by theparty responsible
for compliance could void the User’s authority to operate the equipment.
This Device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This Device may not cause harmful interference, and
- this Device must accept any interference received, including interference that may causeundesired operation.
FCC Radiation Exposure Statement:
This Device complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should beinstalled and operated with
minimum distance 8 inches (20cm) between the radiator & User’s body.
This transmitter must not be co-located or operating inconjunction with any
other antenna or transmitter.
Class B digital device:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
JSG-M004 data sheet
Physical|
---|---
Size| W65xD4Ox H20 mm
Weight| 50g
Environment|
Operating temperature| -20 degrees C to +60 degrees C
Storage temperature| -30 degrees C to +80 degrees C
Performance|
Maximum electric power consumption| 2mA/3 V
Standby electric power consumption| 1 mA / 3V
Version|
Hardware version| 1.00
Software version| 1.00
System Block diagram
Appearance
Components
- Power (CR2477)
- BLE Module
Installation
BLE is installed on the engine cover covering the flywheel.
BLE detects engine on/off state by measuring magnetic field using the internal
magnetic sensor.
This product used at a distance 8 inches (20cm) or more from the User’s body.
Since this product is fixed to the construction machine with magic tape, it is
used with the human body at a distance of 8 inches or more.
Ver 1.0 Sage Co.,Ltd.
April 21, 2022
Date: 2022/4/21
Contact Information Taiki Urasaki Engineer
t.urasaki@jsage.co.jp
Sage Co., Ltd.
2F,KY- Bldg. 2-24 Sumiyoshi-Cho Naka-Ku
Yokohama City KanagawaPref 231-0013 Japan
Sage Co., Ltd.
2F,KY- Bldg. 2-24 Sumiyoshi-Cho Naka-Ku
Yokohama-City Kanagawa Pref
231-0013 Japan
Documents / Resources
| Sage
JSG-S006 BLE
Sensor
[pdf] User Manual
JSGS006, VRBJSGS006, JSG-S006 BLE Sensor, JSG-S006 Sensor, BLE Sensor, Sensor
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>