Sercel WiNG Field Monitor Box User Manual

June 9, 2024
Sercel

Sercel WiNG Field Monitor Box User Manual
Sercel WiNG Field Monitor Box

Guidelines for Safe and Efficient Use

Read this information before using your FIELD MONITOR BOX.

Warnings, Cautions, and Important notices throughout this manual guide you to avoid injury, prevent equipment damage, and determine equipment use when varying components or configurations exist. Notes provide tips or additional information.

SERCEL is not responsible for damages or injuries that result from failure to observe the information provided.

WARNING: When a Warning or Caution appears with a lightning-bolt icon, as shown in this example, this is to indicate a potential hazard that may lead to bodily injury or even death.

CAUTION: When a Warning or Caution appears with an exclamation-point icon, as shown in this example, this is to indicate possible equipment damage or potential risk of misuse and incorrect operation.

IMPORTANT: Important notices appear in the manual to highlight information that does not affect the risk of bodily injury, death, or equipment damage, but is nevertheless important. These notices appear with a stop-sign icon, as shown in this example.

Description

The Field Monitor (Field Monitor Box and Field Monitor Device) is used to collect seismic sample data and QC data from Field Units deployed in the field,
Product Description

and to transport this data to the Central Unit where it can be uploaded to the DCM system server.
Product Description
The Field Monitor Box connects to the USB port of the DCM Server or an available USB port of the DCM Nodal Laptop PC.

The Field Monitor is composed of two devices to connect to the field units wirelessly:

  • The Field Monitor Box is used to bridge to the proprietary wireless communication protocol.
  • The Field Monitor Device allows you to monitor several field units simultaneously, using Pathfinder technology,
  • You may also perform QC harvesting (State of health & numeric values)
  • It can also harvest a few traces of seismic data from a single field unit for data QC.

Description of radio protocol

Frequency range and channel spacing
The frequency range covered by the equipment is 2402.5MHz up to 2478.5MHz, using 1MHz channel spacing. According to FCC rules FHSS (Frequency Hopping Spread Spectrum) scheme is used, on 20 different frequencies.

Data rate
Data rate is 1Mbps with GFSK modulation.

FHSS
The FHSS operates on a set of frequencies. It uses one frequency for a fixed period of time and then switches to another channel. The next frequency is given by a pseudo-random sequence.
In order to communicate, the transmitter and the receiver have to us the same set of frequencies, the same frequency sequence defined by the Frequency key.
Transmitter and receiver are time synchronized thanks to the GNSS receiver module that delivered a PPS signal to the microcontroller. So both transmitter and receiver switch their frequency at the same time.
Radio protocol

Listen Before Talk (LBT) and backoff
The LBT is based on a Channel Control Access mechanism. DFU radio measures the Received Signal Strength Indication (RSSI) before beginning packet transmission. If the RSSI is too high, the media is said “busy” and the DFU postpones the transmission for a random back off time.

GPS configuration

List of allowed GNSS constellations (GLONASS, GPS)

  • GPS Only is the default mode
  • GLONASS only
  • GPS + GLONASS

Navigation model

  • Stationary (Default mode)
  • Pedestrian

Deployment

Recharge battery
Take care of the orientation of the connector when plugging to the FIELD MONITOR BOX.
The two locking ribs should be facing up.
Recharge battery

CAUTION: Use only GLOBTEK WR9MA2000USBMF USB charger or equivalent in accordance with the local standards.

Maintenance

IMPORTANT: Do not use any aggressive chemicals (like petrol or gasoline) liable to attack plastic. Prior to connecting any plug, make sure there is no water inside connectors.

Electrostatic discharge:
Use the following guidelines to provide a static-free repair station that will preclude any ESD-related damage to electronic circuits:

  • All spare parts (circuit boards and ESD sensitive devices) should be stored and transported in static- shielding bags.
  • Unless the repair station rests on a conductive floor, chairs or stools should rest on a grounded, rigid-type, staticdissipative floor mat.
  • Use a static-dissipative table mat.
  • Wear a static-control wrist strap or foot grounder.
  • Provide common-point grounding for all conductive items (including personnel and soldering iron tip).
  • To control the discharge rate and protect workers from electric shocks, both the table mat and wrist strap should be grounded through a 1-MΩ resistor. The mat should be connected to the same earth ground point as the wrist strap.
  • Wear static-dissipative garments.

Battery

**** Use only the type of battery provided by Sercel: WING FIELD MONITOR PACK BATTERY 19.6 WH, ref. 10046318

Caution: risk of explosion if the battery is replaced by an incorrect type.

Do not put the battery in a fire or a hot oven. Do not crush or cut the battery as this could cause an explosion.

  1. Shut down the FMB using the Power stick.

  2. Untighten the 6 SCREWS DELTA PT 40×16 on cover (screw head type : TORX T20).
    Battery Installation

  3. Unplugged the battery connector (A) from the electronic board.

  4. Unplugged the USB cable(B) from the electronic board.

  5. Unplugged the Wifi antenna cable(C) from the electronic board.

  6. Remove the silica gel sachet (D).
    Battery Installation

  7. Pull the electronic out.

  8. Place BATTERY PACK in the two shock absorbers.
    Battery Installation

  9. Place a new silica gel sachet (RS 388-8421) in the tabs of the shock absorbers.

  10. Connect the USB cable (B) and the Wifi antenna cable(C) to the electronic board.

  11. Connect the battery connector (A) to the electronic board

  12. Close the FMB with the cover. Tighten the 6 SCREWS DELTA PT 40×16 (screw head type: TORX T20 ; torque 2,1Nm).
    Battery Installation

Do not discard Sercel product batteries in the trash.


CAUTION:
This product contains sealed batteries and must be disposed of properly. For more information, contact your local recycling/reuse or hazardous waste center.

Operating Voltage 3,6V (2,5V to 4,2V)
Battery capacity (nominal) 5800 mAh
Battery autonomy Up to 10h
Charging time 3hrs (fully discharged – fully charged)
Input Voltage 5V (USB) – (230Vac / 5V 2A for USB Charger)
Dimensions (HxWxD): 152mm (6″) x 110mm (4.33″) x 47mm (1.85″)
Weight 565g
Operating Environment IP67
Operating Temperatures -20°C to +60°C
Storage Temperatures -40°C to +60°C
Battery charge temperatures 0°C to +30°C
Pollution degree II
Altitude functioning < 2000m
FIELD MONITOR BOX


FIELD MONITOR DEVICE| Between FIELD MONITOR BOX

FIELD UNIT
---|---|---
Radio data rates| 802.11a, g: 54Mbps / 802.11n: 450Mbps| 1Mbps
Radio Frequency Characterisitics: Frequency bandSpreading methodNumber of channels| 2,4GHz : 802.11g5GHz : 802.11a, n| 2402 MHz – 2478 MHz GFSK FHSS3 x 20
Radiated output power| 20dBm| 14dBm
Supported GNSS Constellations| GPS, GLONASS

Product Dimensions

Regulatory Information

European Union Statement

Sercel products meet the essential requirements of Directives

  • RED 2014/53/UE (Radio)
  • 2014/ 30/UE (EMC)
  • 2014/35/UE (Low Voltage)
  • 2011/65/UE (ROHS).


IMPORTANT:
The WiNG Field Monitor is a class-A device. In residential areas, the user may be requested to take appropriate measures in the event of RF interference caused by this device.

FCC US Statement

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

This equipment complies with FCC’s radiation exposure limits set forth for an uncontrolled environment under the following conditions :

  1. This equipment should be installed and operated such that a minimum separation distance of 20cm is maintained between the radiator (antenna) and user’s/nearby person’s body at all times.
  2. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

IC Canadian Statement

SERCEL products comply with Industry Canada EMI Class A requirements according to ICES-003 and RSS Gen.

Note These devices comply with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:

  1. These devices may not cause interference; and
  2. These devices must accept any interference, including interference that may cause undesired operation of the device.

This equipment complies with RSS102’s radiation exposure limits set forth for an uncontrolled environment under the following conditions:

  1. This equipment should be installed and operated such that a minimum separation distance of 20cm is maintained between the radiator (antenna) and user’s/nearby person’s body at all times.
  2. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals