Schneider Electric TM5C24D18T Electric Modicon Instruction Manual
- June 9, 2024
- Schneider Electric
Table of Contents
Electric Modicon
Instruction Manual
TM5C24D18T/ TM5C12D8T/ TM5C24D12R
TM5C24D18T Electric Modicon
- Integrated bus base and electronic modules
- Terminal blocks
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
- Disconnect all power from all equipment including connected devices prior to removing any covers or doors, or installing or removing any accessories, hardware, cables, or wires except under the specific conditions specified in the appropriate hardware guide for this equipment.
- Always use a properly rated voltage sensing device to confirm the power is off where and when indicated.
- Replace and secure all covers, accessories, hardware, cables, and wires and confirm that a proper ground connection exists before applying power to the unit.
- Use only the specified voltage when operating this equipment and any associated products.
Failure to follow these instructions will result in death or serious injury.
DANGER
POTENTIAL FOR EXPLOSION
- Only use this equipment in non-hazardous locations, or in locations that comply with Class I, Division 2, Groups A, B, C and D.
- Do not substitute components which would impair compliance to Class I Division 2.
- Do not connect or disconnect equipment unless power has been removed or the area is known to be non-hazardous.
Failure to follow these instructions will result in death or serious injury.
Electrical equipment should be installed, operated, serviced, and maintained
only by qualified personnel.
No responsibility is assumed by Schneider Electric for any consequences
arising out of the use of this material.
| | | |
---|---|---|---|---
mm²| 0,08…2,5| 0,25…2,5| 0,25…1,5| 2 x 0,25…2 x 0,75
AWG| 28…14| 24…14| 24…16| 2 x 24…2 x 18
Use copper conductors only.
WARNING
UNINTENDED EQUIPMENT OPERATION
-
Use appropriate safety interlocks where personnel and/or equipment hazards exist.
-
Install and operate this equipment in an enclosure appropriately rated for its intended environment and secured by a keyed or tooled locking mechanism.
-
Use the sensor and actuator power supplies only for supplying power to the sensors or actuators connected to the module.
-
Power line and output circuits must be wired and fused in compliance with local and national regulatory requirements for the rated current and voltage of the particular equipment.
-
Do not use this equipment in safety-critical machine functions unless the equipment is otherwise designated as functional safety equipment and conforming to applicable
regulations and standards. -
Do not disassemble, repair, or modify this equipment.
-
Do not connect any wiring to reserved, unused connections, or to connections designated as No Connection (N.C.).
Failure to follow these instructions can result in death, serious injury, or
equipment damage.
WARNING
POTENTIAL OF OVERHEATING AND FIRE
- Do not connect the equipment directly to line voltage.
- Use only isolating PELV power supplies to supply power to the equipment.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
- Digital Input 12In: Input electronic module, 12 digital inputs
- Digital Output 6Out: Output electronic module, 6 digital outputs
- Digital Input 4In: Input electronic module, 4 digital inputs
- Digital Output 4Out: Output electronic module, 4 digital outputs
- Digital Output Relay 6Rel: Relay output electronic module, 6 relay outputs
- Dummy module
Wiring Diagrams
Legend
1 | Internal electronics |
---|---|
2 | 24 Vdc I/O power segment integrated into the bus bases |
3 | 3-wire sensor |
4 | 2-wire sensor |
5 | 24 Vdc I/O power segment by external connection |
6 | External power supply 100…240 Vac |
7 | Inductive load protection |
8 | 2-wire load |
9 | External isolated power supply 24 Vdc |
10 | External fuse type T slow-blow 2 A 250 Vac |
11 | 3-wire load |
(I) | Current |
(U) | Voltage |
Eurasian Economic Union (EAEU) contact information:
For Russia:
Уполномоченный поставщик в РФ:
АО “Шнейдер Электрик”
Адрес: 127018, Россия, г. Москва,
ул. Двинцев, д.12, корп.1
Тел. +7 (495) 777 99 90
Факс +7 (495) 777 99 92| For Kazakstan:
Қазақстан Республикасында ресми жеткізуші:
ЖШС “Шнейдер Электрик”
Мекен-жайы: Қазақстан Республикасы,
Алматы қ., Достык даң., “Кен Дала” Бизнес
Орталығы, 5-ші қабат.
Тел.: +7 (727) 357 23 57
Факс.: +7 (727) 357 24 39
---|---
UK Representative
Schneider Electric Limited
Stafford Park 5
Telford, TF3 3BL
United Kingdom
BBV56043 04
www.se.com