HINKLEY 3222 Hathaway 26 Inch Large Pendant Instruction Manual
- June 9, 2024
- HINKLEY
Table of Contents
3222 Hathaway 26 Inch Large Pendant
Instruction Manual
Assembly Instructions
Item No: 3222 / 3224
- Find a clear area in which you can work.
- Unpack fixture and glass from carton.
- Carefully review instructions prior to assembly.
** The construction of this fixture will be accomplished by first assembling the main body of the fixture, determining the length of stem required, mounting the mounting strap to the junction box, making all necessary electrical connections, hanging the fixture from the ceiling, and then installing the glass. It is recommended that assistance be available when installing this fixture
-
Slip threaded end (B) of upright (2) into the recessed hole (A) of canopy (1) – see Drawing 1.
-
Slip lock washer (3) onto threaded end (B) of upright (2). Then thread on hex nut (4) do not tighten at this time.
-
Repeat steps 1 and 2 for remaining uprights. After uprights are in place attach ring (9) to the bottom end of the uprights temporarily using knob with stud (11). Slip threaded stud (11) through hole (F) in ring upright (G) with hole (E) in upright (2). Slip threaded stud (11) through hole (F) in ring upright (G) and thread into hole (E). Align uprights and adjust to vertical. Then tighten hex nuts (4) in canopy to secure uprights.
-
Slip cap (5) along wire and place on top of canopy (1).
-
Slip coupler (5) along wire and thread onto threaded tube (C) and tighten.
-
The diffuser (7) is attached by first removing the ball knob studs (8) from the cluster plate (D).
-
Place diffuser (7) onto top of cluster plate (D) and line up the holes.
-
Thread ball knob studs (7) back into cluster plate (D) to secure diffuser. Repeat process for opposing diffuser.
-
Please refer to the hanging instruction sheet (I.S. 19-90) provided to hang your fixture from the ceiling. Then refer back to this sheet to complete assembly.
-
Prior to installing the glass fixture can be lamped accordingly.
-
To install glass, remove two of the knob with studs (11) that attach the ring (10) to the uprights (2).
-
Now loosen the one remaining knob with stud (11) so the ring (10) is supported at this point.
-
Carefully tilt ring downward and slip glass (9) into ring.
-
Tilt ring and glass back into position and thread knob and studs removed earlier into place and tighten to secure glass.
Mounting Instructions IS19-90
- Find a clear area in which you can work.
- Unpack fixture and glass from carton.
- Carefully review instructions prior to assembly.
Shut off electrical current befoer starting. If the fixture you are replacing
is turned on and off by a wall switch, simply turn the switch off. If not,
remove the appropriate fuse (or open the circuit breakers) until the fixture
is dead.
– DO NOT restore current – either by fuse, breaker, or switch – until the new
fixture is completely wired and in place.
STEP 1
- Determine the desired height the pendant will be installed.
- The fixture is supplied with assorted stem sizes. Determine what combinations of stems are needed to achieve desired length – see Drawing 1.
- Slip stems over wire and thread first stem onto top of pendant, longest stem first. Repeat this process until all required stems are threaded together.
- Slip wire through center hole of canopy swivel and thread swivel onto the top of the last stem installed.
STEP 2
- Thread two long 8-32 screws (1) into the bent part of strap (2). NOTE: two screws must be threaded into holes that match the mounting hole spacing (M) on the canopy (3) – see Drawing 2.
- Attach the mounting strap (2) to the junction box with two 8-32 screws (5) [NOT PROVIDED]
- Now with assistance take the assembled fixture and lift it up and using hook on end of inspection cable (I), attached to the inside of canopy (C), hook it into the mounting strap. Now slowly release the fixture until it is safely hanging from the inspcetion cable – see DETAIL 2. NOTE: It is still recommend that an assistant be used to support fixture during this process.
- Make electrical connections following instruction sheet [FRIS18] provided.
- To install fixture, first lift assembled fixture up to ceiling and slip screws (1) on mounting bracket through holes (M) in canopy (3). Secure fixture to ceiling by threading ball knobs (4) onto end of screws (1) and tightening.
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY
ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW
WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR
CODE REQUIREMENTS.
Note: Use IS Wiring Instructions for 0-10 volt LED dimmer to wire the LED
version of the fixture
Wiring
Instructions for 0-10 volt LED dimmer
Your fixture is designed so it can use a standard incandescent dimmer, Or a 0-10 volt LED dimmer. If a 0-10 volt LED dimmer is used, it may be necessary to have additonal wiring installed from the dimmer switch to the fixture. Consulting an electrician will be necessary.
- If using the optional 0-10 volt dimmer there will be four wires exiting the junction box. (B) Black [+], (W) White [-], wirng are for the 120 / 277 voltage. The (G) Gray {-} and (P) Purple {+} are for the 0-10 volt wires from the dimmer (D) – see Drawing 1.
- The fixture has four wires of corrisponding colors. When make the wire connections follow the chart below.
Black (B) from junction box (J) wired to Black (B) from fixture (F).
White (W) from junction box (J) wired to White (W) from fixture (F).
Gray/Pink(G) from junction box (J) wired to Gray/Pink (G) from fixture (F).
Purple (P) from junction box (J) wired to Purple (P) from fixture (F)
Connect ground wire from fixture to ground screw on mounting hardware
INCANDESCENT DIMMER USAGE:
If using an incadescent dimmer follow manufactures instructions.
NOTE: MAKE SURE TO CAP OFF THE GRAY AND PURPLE WIRE FROM THE FIXTURE
INSIDE THE CANOPY. IF THE ARE NOT CAPPED THEY CAN SHORT OUT AND CAUSE THE
FIXTURE TO FAIL.
I.S. 18
Wiring grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY
ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW
WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR
CODE REQUIREMENTS
Wiring instructions
Indoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
- Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections
Outdoor Fixtures
-
Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – – – see Drawings 2 or 3.
-
Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
-
Cover open end of connectors with silicone sealant to form a watertight seal.
∎ If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially. -
Please refer to the grounding instructions below to complete all electrical connections.
Grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground
wire (E) (typically copper or green plastic coated) to the fixture mounting
strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two
mounting screws in strap. Any remaining tapped hole may be used for the ground
screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated)
under the head of the ground screw (S) on fixture mounting strap (M) and
connect to the loose end of the fixture ground wire directly to the ground wire
of the building system with appropriately sized twist-on connectors – see
Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to
power supply ground with appropriately sized twist-on connector inside post.
Cover open end of connector with silicone sealant to form a watertight seal –
see Drawing 3.
A Division of Hinkley Lighting, Inc.
33000 PIN OAK PARKWAY
AVON LAKE, OHIO 44012
Toll free 800.446.5539
Phone 440.653.5500
HINKLEY 33000 Pin Oak Parkway, Avon Lake, OH 44012
800.446.5539 / 440.653.5500
hinkley.com
Documents / Resources
|
HINKLEY 3222 Hathaway 26 Inch Large
Pendant
[pdf] Instruction Manual
3222 Hathaway 26 Inch Large Pendant, 3222, Hathaway 26 Inch Large Pendant, 26
Inch Large Pendant, Large Pendant
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>