GERMI GIMA PLUS Germicidal Lamp User Manual

June 9, 2024
GIMA

GERMI - logo LAMPADA GERMICIDA
GERMICIDAL LAMP
GERMI GIMA PLUSGERMI GIMA PLUS Germicidal Lamp

MANUALE D’USO
USER MANUAL

GERMI GIMA PLUS Germicidal Lamp

ATTENTION: The operators must carefully read and completely understand the present manual before using the product.

INSTRUCTION

DESCRIPTION OF PRODUCT
Germicidal lamp ideal for the employment in aesthetical field and ambulatory field.
It maintains the sterilization of surgical or aesthetical irons.
It isn’t adapt for sterilizing. It isn’t a medical device. Furnished in 3 different models according to the demands.
Built with body in metal with elevated resistance and equipped with digital timer for activating the lamp: GERMI GIMA PLUS Germicidal Lamp -
PRODUCT

  1. START Button and timer (Image A)
  2. Safety Swatch (Image B)
  3. Front Cover (Image C)

PRECAUTIONS

CAREFULLY CONSULT THE INSTRUCTION MANUAL BEFORE USING THE EQUIPMET THE EQUIPMENT MAY ONLY BE UTILIZED BY QUALIFID PERSONNEL DON’T OPEN THE EQUIPMENT
FOR A TECHNICAL ASSISTANCE CONTACT GIMA AFTER SALES SERVICE

GIMA does everything within its power to ensure that its products are safe to use.
It is, however, of fundamental importance to observe the basic rules of safety in order to avoid electric shocks or fires.

  1. On using the equipment for the first time, and on each successive occasion, check that the power cord cable is not damaged, split or peeling. If it is, do not insert the plug  in the electric socket
  2. On using the equipment for the first time, check that no parts of it have been broken, cracked or opened during transportation. If so, do not insert the plug in the socket
  3. Do not handle the plug with wet or damp hands. Do not use the equipment in the shower or in the bath.
  4. Do not immerse the equipment in water
  5. Do not allow children or incapable people to use the equipment without supervision
  6. Do not leave the equipment exposed to atmospheric agents or heat sources
  7. Do not utilize the equipment for uses other than those foreseen by the manufacturer. Any different use must be considered incorrect and therefore dangerous; the  manufacturer cannot be considered liable for damage caused by improper, incorrect and / or unreasonable use or if the appliance is used in electrical plants that are not in compliance with the regulations in force;

IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2012/19/UE-WEEE:
The symbol on the device indicates the separated collection of electric and electronic equipment. At the end of life of the device, don’t dispose it as mixed solid municipal  waste, but dispose it referring to a specific collection centre located in your area or returning it to the distributor, when buying a new device of the sample type to be used  with the same functions. This procedure of separated collection of electric and electronic devices is carried out forecasting a European environmental policy aiming at safeguarding, protecting and improving environment quality, as well as avoiding potential effects on human health due to the presence of hazardous substances in such equipment or to an improper use of the same or of parts of the same
Caution: The wrong disposal of electric and electronic equipment may involve sanctions.

TECHNICAL SPECIFICATIONS

Model GERMI GIMA PLUS
Supply 230V / 50Hz
Power Consuption A secondi del modulo 10W – 18W – 35W
Fuse 2 x 1 A
Operative Condition Room temperature: 5 ÷ 35°C

Room humidity temperature: 30 ÷ 75% RH
Storage Condition and Transporting| Room temperature: -40 ÷ 70°C Room, humidity temperature: 10 ÷ 100% RH

SIMBOLOGY

| Mark of conformity to the European Directive 2014/35/EU; 2014/30/EU
Manufactured by: CA-MI Syl – Via Ugo La Malta n°13
43010 Plastron (PR) Italia
---|---
| Warning, consult the instruction manual
| Fuse

230V ~

| AC Voltage

Hz

| Frequency
| To preserve in place coolness and dry land
| Conservation temperature: -40 ÷ 70 °C

IN THE EVENT OF A FAILURE OR MALFUNCTIONING DON’T ATTEMPT TO REPAIR THE EQUIPMET, BUT CONTACT GIMA AFTER SALES SERVICE IMMEDIATELY
IF, ON INSPECTION OF THE EQUIPMET BY GIMA AFTER SALES SERVICE, THE EQUIPMENT IS FOUND TO HAVE BEEN TAMPERED WITH, THE GUARANTEE WILL BE CONSIDERED NULL AND VOID.

USER INSTRUCTIONS

Principle of operation:
This device maintains sterilization through irradiation with short wave ultraviolet rays .
The vapor of mercury at low pressure contained in the lamp, submitted to electric discharge, give out a short wave radiations that will be distribute for the 90% around the  frequency of 253,7 nm, and in tall frequencies the lamp give out a visible light of bluish color.
It is just around the 253,7 nm that is developed the maximum germicidal power.
Germicidal action:
The ultraviolet radiations are lethal for the microorganisms.
The quantity of radiation necessary to destroy a microorganism depends from the type of the microorganism and from the environmental conditions.
The lethal dose of radiation UV for a determined microorganism depends therefore from the intensity of the source, from the exposure time and from other factors like  temperature, damp and the reflection formalities of the rays. Our apparatus has been planned and built in way to maximize the effect of the radiations and to assure an  optimal result in varied uses.
It is ideal for a suitable maintenance of the tools after the sterilization.
The following chart points out the necessary times, express in second, for the destruction of some microorganisms.

Microorganism| Seconds| Microorganism| Seconds| Microorganism| Seconds
---|---|---|---|---|---
Strains|  | Protozoa|  | Aspergillus Fauves| 165
Streptococcus Lactis| 9| Paramecium| 333| Aspergillus Niger| 550
Streptococcus Hem lyrics| 10| Nematode eggs| 36| Rhizopus Nigricans| 366
Staphylococcus Auras| 10| Chlorella vulgaris| 36| Micro Racemases A| 58
Micrococcus Spheroid.| 25| Virus|  | Oospore lactis| 18
Sardinia Lutea| 44| Bacteriophage| 10|  |
Fluorescents di Pseudomonas| 18| Tobacco mosaic| 733| Yeasts|
Escherichia Coli| 11| Influenza| 10| Ellipsoids di Saccharomyces| 22
Proteus Vulgarism| 13| Mold Stores|  | Spa di Saccharomyces.| 29
Serratia Marcescens| 10| Penicillium Roquefort| 45| Cerevisiae di Saccharomyces| 22
Bacilli Subtilis| 18| Penicillium Expanse| 36| Brewer’s yeast| 11
Mycobacterium tuberculosis| 36| Penicillium Digitate| 146| Bakers yeast| 14
Spirillum| 10| Aspergillus Glaucus| 146|  |

INSTRUCTION and OPERATION

  • Position the appliance on a flat, stable and clean surface. CAUTION: the Power Cable Socket must always be free from any obstruction in the event of an emergency
  • Connect the electric cable to the net.
  • Open the frontal cover using the special handle grip
  • Insert on the intern grate the tools that it intends each other to maintain sterile.
  • Close the frontal cover
  • Select the desired operating time by setting the timer: pressing the + button increases the operating time, pressing the – button decreases the operating time

From 0” to 10” increase of 1”
From 10” to 90” increase of 10”
From 2′ to 9′ max increase of 1′
From 9′ to 2′ decrease of 1′
From 90” to 10” decrease of 10”
From 10” to 0” decrease of 1”

  • After setting the operating time, press the START button to start the treatment
  • To reset the setting, hold the START button for 3 seconds
  • The lamp switches off automatically after the set time has elapsed
  • Open the front door and remove the instruments previously inserted

GERMI GIMA PLUS Germicidal Lamp - Fig1

The apparatus is furnished with a safety switch that prevents the operation with the frontal cover open.
Before turning on the apparatus always close the frontal counter.

MAINTENANCE

  • Clean the lamp with cotton soaked with alcohol.
  • Perform this operation with the apparatus turned off and with cable disconnected from the alimentation.
  • Clean the frontal cover with water and soap.
  • Don’t use solvents.
  • Replace the lamp every 2-3000 ours.
  • To replace the lamp rotate it by 90° and pull it downwards. Repeat the operation in the opposite way to install the spare lamp.

WARRANTY
GIMA warrants it’s products for 24 months after purchasing date. In front of this warranty, GIMA will be obliged only to repair or substitute free of charge the products or  parts of them that, after verification effected on our factory, or our authorized Service Center, by the Technical Service, results defective. The product must be accompanied  by a description of the defect. The warranty, with exclusion of responsibility for direct and indirect damages, it is thought limited to the solos defects of material or workmanship and it stops having effect when the device results however gotten off, tampered or sheltered out of the Factory or from the Authorized Service center. The  commodity always travels to risk and danger of the buyer, without any responsibility of GIMA for damages caused by the transport or dismay from the vector.

Device model__
Purchasing date____
Authorized dealer___
Street
Place
Purchased By__
Street
Place
FOR WARRANTY REPARATIONS THE POSTCARD WILL BE RETURNED WITH THE DEVICE
AUTHORIZED DEALER STAMP AND SIGNATURE GERMI - logo

GIMA S.p.A. – Via Marconi, 1 – 20060 Gessate (MI)
ITALIA: Tel. 02 953854.1 – Fax. 02 95381167 / e-mail:
gima@gimaitaly.comwww.gimaitaly.com
INTERNATIONAL:
Tel. +39 02 953854209/221/225 –
Fax. +39 02 95380056
e-mail: export@gimaitaly.comwww.gimaitaly.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals