ELKRON EP3008 8-Point Wired Expansion Board Instruction Manual
- June 9, 2024
- ELKRON
Table of Contents
EP3008 8-Point Wired Expansion Board
Instruction Manual
EP3008 8-Point Wired Expansion Board
● Complete manual
http://qrcode.urmet.com/default.aspx?sito=Elkron&prodElkron=146498&lingua=it
• LEGEND
A| +| • Power positive (13,8 V )
A / B| • BUS Data transmission/reception NB
–| • Power negative (Gnd)
B| TAMPER| • Tamper input
C| PWR| • BUS power present LED (+13,8 V )
D| +3V3| • Logic power present LED (+3,3 V )
E| BUZZER| • Buzzer for acoustic indications
F| ALARM| • Alarm LED
G| BUS| • BUS interface LED
H| LP1…LP8| •LED LP1 (PrIO 1) … LED LP8 (PrIO 8)
I| +V| • Power positive PrIO (13 V )
| – V| • Power negative PrIO (Gnd)
| Px| • PrIO programmable input/output x (x = 1…8)
L| | • Holes for fixing in generic boxes
| SYMBOL KEY
---|---
| Direct current power voltage
● Possible housings inside the control unit
• TECHNICAL FEATURES
• Nominal supply voltage ,| | 13,8 V-
• Operating voltage| | 101 14,5 V-
• Rated absorbed current (Single-balanced)| | 36,5 mA (13,8 V—)
• Max. current deliverable to PrIO terminal| | 50 mA
• Max. current deliverable from all terminals| | 750 mA
• Dimensions (L x H)| | 89 x 75 mm
• Maximum bus length| 2×0,75 mm² + 2×0,22mm²| 500 m
• EN50131 certification| • Grade| 3
• Class| II
This document contains only essential information about the product. Refer to the manuals of the MP3000 panel for more information.
GENERAL DESCRIPTION
The EP3008 is an expansion module with 8 points (PrIO) that can be individually programmed as input or output. The module is connected to the control panel via BUS
ASSEMBLY
The expansion module can be mounted inside the control panel or in CP/EXP wall
boxes, with the tamper switch connected to the TAMPER input, or CP-EP500.
It can be installed inside distribution boxes or similar containers,
adequately protected by tamper-proof devices.
IMPORTANT: The only installation methods that comply with EN50131 are
those that require the presence of the tamper protection.
Position the expansion module in a low-traffic, indoor location, not subject
to excessive temperature fluctuations and protected by the intrusion alarm
system and away from strong electromagnetic fields.
BUS CONNECTION
The expansion module can be connected on the bus in cascade, in either star or
mixed mode. The position along the bus is irrelevant. The total length of the
bus must not exceed 500 meters (cable cross-section area 2×0.75 mm² power +
2×0.22 mm² data). Connect the expansion module to the bus, using terminals +,
A, B and ─.
When calculating the overall system consumption, take the maximum consumption
of the expansion module and also of the devices connected to it into account.
INPUT/OUTPUT CONNECTION (PrIO)
Connect the detectors to PrIO P1…P8 programmed as input. They can be
individually programmed as NC, NO, Balanced, Double Balanced, Triple Balanced
and Tandem. Management of fast signals from seismic sensors or shutters.
IMPORTANT: “Double balanced” and “triple balanced” connection modes are
the only ones compliant with EN50131. The specialization (intrusion,
tampering, robbery, panic, technical etc.) is specified by programming.
Connect output devices (e.g. indicators) to PrIO P1…P8 programmed as output.
Electrical outputs are negative. The stand-by state of each output is
programmable as Positive present or No positive.
IMPORTANT: Never exceed the current or voltage values supported by the
outputs (see technical specifications of the devices to be connected).
EXPANSION MODULE ACQUISITION
Acquisition is carried out either automatically using the peripheral device
search function of the control panel or in manual mode. See the MP3000 control
panel programming manual for more details..
ELKRON
Tel. +39.011.3986711
Fax +39.011.3986703
www.elkron.com
info@elkron.it
ELKRON is a trademark of URMET S.p.A.
Via Bologna, 188/C 10154 Torino (TO) – Italy
www.urmet.com
Made in Italy
DS80MP7L-001 LBT81107