HINKLEY 3487PT Argo 14 Inch LED Large Pendant Instruction Manual

June 9, 2024
HINKLEY

HINKLEY 3487PT Argo 14 Inch LED Large Pendant

Assembly Instructions

item no. 3483 / 3487
start here
Find a clear area in which you can work.
Unpack fixture and glass from carton.
Carefully review instructions prior to assembly.

  1. To begin assembly of your luminaire first take socket body (1) and set it on top of shade (BE CAUTIOUS SO THE PAINT IS NOT SCRATCHED.

  2. Now align holes in brackets (B) with holes in shade (2).

  3. Now slip screws (3) provided, into aligned holes.

  4. Next reach under shade and thread on ball knob (4) to secure shade to brackets.
    Note: For easier install wait to completely tighten down screws untill all brackets are installed

  5. Luminaire is ready to be installed. Please follow mount ing instructions provided.

Mounting Instructions

Shut off electrical current befoer starting. If the fixture you are replacingis turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circuit breakers) until the fixture is dead. DO NOT restore current either by fuse, breaker, or switch – until the new fixture is completely wired and in place.

STEP 1.

  1. Determine the desired height the pendant will be installed.
  2. The fixture is supplied with assorted stem sizes. Determine what combinations of stems are needed to achieve desired length see Drawing 1.
  3. Slip stems over wire and thread first stem onto top of pendant, longest stem first. Repeat this process until all required stems are threaded together.
  4. Slip wire through center hole of canopy swivel and thread swivel onto the top of the last stem installed.

STEP 2

  1. Thread two long 8-32 screws (1) into the bent part of strap (2).
    NOTE : two screws must be threaded into holes that match the mounting hole spacing (M) on the canopy (3) – see Drawing 2.

  2. Attach the mounting strap (2) to the junction bOx with two 8-32 screws (5) [NOT PROVIDED]

  3. Make electrical connections following instruction sheet [FRIS18] provided.

  4. Assistance is recommended during installation of the fixture to the ceiling.

  5. To install fixture, first lift assembled fixture up to ceiling and slip screws (1) on mounting bracket through holes (M) in canopy (3). Secure fixture to ceiling by threading ball knobs (4) onto end of screws (1) and tightening

SAFETY WARNING : READ WIRING AND GROUNDING INSTRUC- TIONS (1.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULTAQUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (1.S. 18) and follow all instructions to make all necessary wiring connections. Then refer back to this sheet to complete installation of this fixture.

I.S. 18 wiring grounding instructions

SAFE TY WARNING: READ WIRING AND GROUNDING INSTRUCTIO NS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

wiring instructions
Indoor Fixtures

  1. Connec t positive supply wire (A ) (typically black or the smooth,
    unmarked side of the two-conduc tor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.

  2. Connec t negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).

  3. Please refer to the grounding instructions below to complete all electrical connections

Outdoor Fixtures

  1. Connec t positive supply wire (A) (typically black or the smooth unmarked side of the two-conduc tor cord) to positive fixture lead (B) with appropriately sized twist on connector — see Drawings 2 or 3.
  2. Connec t negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Cover open end of connectors with silicone sealant to form a watertight seal. If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backpla te) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
  4. Please refer to the grounding instructions below to complete all electrical connections.

Grounding instructions

Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M ) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.

Chain Hung Fixtures
Loop fixture ground wire (E) (typically coppe r or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Draw in g 2.

Post-Mou nt Fixtures
Connec t fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.
HINKLEY 33000 Pin Oak Parkway, Avon Lake, OH 44012 800.446.5539 / 440.653.5500 hinkley.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals