SPORTSMAN 553703 300-Watt Gasoline-Propane Portable Generator User Manual
- June 9, 2024
- SPORTSMAN
Table of Contents
SPORTSMAN 553703 300-Watt Gasoline-Propane Portable Generator
Step-By-Step Quick Start Guide To Using Your Generator
- Remove Generator From Package
- Add Oil
- Add Fuel
- Start The Generator
- Oil Type : SAE10W-30 Oil (Must add BEFORE first use)
- Oil Capacity : 18.6 fluid oz
- Use the generator OUTDOORS in a WELL VENTILATED AREA.
- DO NOT CONNECT electrical devices until AFTER the generator is started.
- Turn Engine Switch to ON
- Turn FUEL PETCOCK to ON (Figure A)
- Adjust the CHOKE to CLOSED/CHOKE position (Figure B)
- Start the generator manually with the Recoil (Pull) Start.
- Once the engine has started, GRADUALLY move the choke lever to the “RUN/OPEN” position until the engine levels off. Then let the engine run approximately 5 minutes BEFORE adding appliances or tools.
- You can now connect electrical devices.
Because this generator includes Low Oil Shut Off, the generator will not start with low oil. Start out with 18.6 oz, then fill until almost overflowing.) Unleaded gasoline only octane rating of 87 or higherMaximum Capacity: 3.6 Gallon fuel tank
UNLEADED GASOLINE FUEL
GENERATOR SPECIFICATIONS
- 7 HP Engine, 4 Stroke OHV
- Recoil Start
- 3.6 Gallon Fuel Tank
- Low Oil Shut Off
- UL Listed Electrical Components
- Engine Shut Off Switch
- Circuit Breaker & Power Outlets
- 1-12V DC Outlet
- 4 -120V AC Outlets
- 1-120V RV Outlet
- Carbon Monoxide Warning Alert
- Complies with EPA emissions
- Run time = 10 hours @ 50% load
- Decibel Rating < 69 db @ 0% load
- Warranty : 2 YEAR Limited Emissions
- Warranty : 1 YEAR Limited
- If you are using a generator 3,000 ft. above sea level, the generator may not function properly because of air flow getting through the carburetor.
- High Altitude Use : This generator is not recommended for high altitude use 3,000 ft. above sea level.
OIL IS NOT INCLUDED WITH THIS GENERATOR. IT IS SOLD SEPARATELY. Read and understand instruction manual before using generator.
ATTENTION ALERT!
This generator includes a built-in Carbon Monoxide Warning Alert! The
generator will automatically shut-off if dangerous levels of Carbon Monoxide
is detected
CONTROL PANEL DETAILS
DO NOT CONNECT electrical devices until AFTER the generator is started
WARNING
IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE, DO NOT
OPERATE THIS PRODUCT! Always follow Warning labels placed on the generator,
and read and follow all Warning labels included inside the Product Manual.
WARNING : NEVER use a generator inside a home or a garage, EVEN IF the doors and windows are open.
ONLY USE OUTSIDE and far away from windows, doors and vents leading into an enclosed area.Using a generator indoors can kill you in minutes. The generator produces an exhaust that contains carbon monoxide. This is a poison you cannot see or smell. Do not attach a chain or rope to secure the generator to a post as this can be difficult to remove in the event of an emergency. This generator includes a built-in Carbon Monoxide Warning Alert! The generator will automatically shut-off if dangerous levels of Carbon Monoxide is detected. Carbon monoxide (also known as CO) can be dangerous for humans and pets. Carbon monoxide poisoning can lead to death in a very short time. It is called “the silent killer” because it is odorless, tasteless and invisible: you may be exposed without knowing it.
NOTE : The indicator will light RED and the engine will shutdown if dangerous Carbon Monoxide levels are detected. The engine will not restart for 5 minutes. If an error in the carbon monoxide system is detected, the indicator will blink YELLOW and the engine will shutdown for five minutes.
MOVE TO FRESH AIR AND GET MEDICAL HELP IF SICK, DIZZY OR WEAK. MOVE GENERATOR TO AN OPEN, OUTDOOR AREA. POINT EXHAUST AWAY. DON’T RUN GENERATOR IN ENCLOSED AREA (E.G. NOT IN HOUSE OR GARAGE). READ MANUAL FOR COMPLETE CO WARNING INSTRUCTIONS!