Introduction
WARNING: (To reduce the risk of fire, electric shock, or personal injury):
-
We suggest installation by a licensed electrician.
-
Please read the instruction carefully and save it as you may need it at a later time.
-
Before you start, NEVER attempt any work without shutting off the electricity until the work is done.
-
Go to the main fuse, or circuit breaker, box in your home.
Place the main power switch in the “OFF” position. -
Place the wall switch in the “OFF” position.
-
-
Mounting surface should be clean, dry, flat, strong enough and 1/4” larger than the canopy on all sides.
Any gaps between the mounting surface and canopy exceeding 3/16” should be corrected as required. -
Make sure that the ceiling or wall can stand the weight of the lamp before installation.
-
Make sure the voltage you are using is 120V. The maximum wattage is 40W per bulb.
-
Keep the lamp away from acidic and alkaline substances in case of damaging the surface of the lamp.
-
When replacing bulbs, you should turn off or unplug the lamp and you must wait until it is cool as bulbs get hot quickly.
-
The safety instructions appearing in this manual are not meant to cover all possible conditions that may occur.
It must be understood that common sense, caution and care must be used with any electrical products.
IMAGE FOR FINISHED PRODUCT:
TOOLS REQUIRED (NOT INCLUDED):
Before starting assembly and installation please prepare the needed tools as below picture
| | | |
---|---|---|---|---
Ladder| Phllips head. Flat blade screwdriver| Electric tape| Pliers| Wire
cutter/Stripper
PARTS INCLUDING:
- C) Green ground screw (1)
- (D) Mounting plate (1)
- (E) Back plate (1)
- (F) Knob nut (2)
- (G) Arm (2)
- (H) Socket (2)
- (I) Glass shade (2)
(J) Socket ring (2)
ACCESSORIES ENCLOSED:
- (A) Mounting screw (2)
- (B) Plastic wire connector (3)
- (K) Socket wrench (1)
ASSEMBLY & INSTALLATION INSTRUCTIONS
-
Carefully remove the fixture from the carton and check that all parts and accessories are included as shown in the above illustration.
-
Turn off power
Before you start the installation, NEVER attempt any work without shutting off the electricity until the work is done.-
Go to the main fuse, or circuit breaker, box in your home.
Place the main power switch in the “OFF” position. -
Place the wall switch in the “OFF” position.
-
-
Make assembly
-
Step A1: Unscrew knob nuts (F) from back plate (E), then set them aside for later installation.
-
Step A2: Unscrew knob nuts (F) from back plate (E), then set them aside for later installation.
Carefully pass the supply wires from the outlet box through mounting plate (D). -
Step A3: Secure mounting plate (D) to the outlet box with mounting screws (A).
Make wire connections
Connect wires as below wires connection shown.
PLEASE NOTE THAT GROUND WIRE IS BARE COPPER WIRE, NEVER CONNECT OTHER WIRES TO GROUND WIRES.
Connect ground wires according to the below chart
Connect wires according to the below chart
Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
---|---
Black| White
Parallel cord ( round & smooth )| Parallel cord ( square & ridged )
Clear, Brown, Gold or Black without tracer| Clear, Brown, Gold or Black with tracer
Insulated wire ( other than green ) with copper conductor| Insulated wire ( other than green ) with silver conductor
Note: When parallel wires ( SPT I & SPT II) are used.
The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth ( see illus.)|
Twist wires together with plastic wire connectors until tightly joined, and
wrap each connector with approved electrical tape.
Be sure that no wire strands are exposed and then carefully tuck all wires
into the outlet box
-
Step A4: Align the holes in back plate (E) with the preassembled mounting screws, then attach back plate (E) to mounting plate (D) with the previously removed knob nuts (F). Hand tighten until snug.
NOTE: back plate (E) should be snug against the wall with knob nuts (F).
If not, remove back plate (E), adjust the threaded length of preassembled mounting screws on mounting plate assembly (D):- first, unscrew the preassembled hex nuts;
- then, screw the preassembled mounting screws in or out of mounting plate (D);
- when the secure length is achieved, tighten the preassembled hex nuts and back to Step A4.
-
Step A5: 1) Remove socket rings (J) from sockets (H), and carefully place glass shades (I) on sockets (H), then secure them with socket rings (J) using socket wrench (K).
- Install bulbs (Not included) (Please do not exceed the maximum wattage recommended on the socket.)
- Check everything is installed properly, then you could turn on the light. Enjoy!
ORDERING PARTS
Keep this sheet for future reference in case you need to order replacement
parts.
All parts for this fixture can be ordered from the place of purchase.
Be sure to use exact wording from illustration when ordering parts.
CLEANING
To clean, wipe the fixture with a soft cloth.
Clean glass with a mild cleaner (such as mild and nonabrasive soap).
Do not use abrasive materials such as scouring pads or powders, steel wool or
abrasive paper.
CUSTOMER SUPPORT
+1 850 296 2377 Working hours : Mon Fri 9:00 16:00 EST
homecustomercare@outlook.com