Bansbach FWM-2725FBD-S Shock Absorber Instructions
- June 8, 2024
- Bansbach
Table of Contents
Bansbach FWM-2725FBD-S Shock Absorber
PRECAUTIONS FOR USE
- Do not use this product without carefully reading the attached owner’s manual.
- Ensure that an external stopper (Stopper nut OP-020FB) is also used.
- Do not turn the oil inlet screw located at the bottom of the main unit.
- Ensure that sufficient mounting strength is secured for this product. (As a guideline, it should be 2 to 3 times the maximum drag listed in the catalogue.)
- Do not use this product in a vacuum or a location where it may come in contact with oil.
- Ensure that an eccentric load is not applied to the soft absorber. (Allowable eccentric angle: within ±2.5°)
ADJUSTMENT METHOD
- To adjust, turn the adjustment knob located at the bottom of the main unit.
- Because the adjustment can be done in an analog manner, a value between two integers on the indicator can be set.
- Once the adjustment is complete, secure with a lock screw using a hex wrench.
ABSORPTION CHARACTERISTICS
Orifice type| Multiple-orifice type| Absorption characteristics
---|---|---
Model number| FWM-2725FBD Series
Application| For medium speed, in particular with a pneumatic cylinder
SPECIFICATIONS
Model| Stroke
mm| Max Energy Absorption J(kgf ٠ m)| Max Equiv.
Mass
kg(kgf)| Range of Impact Rate m/s| Orifice Type
---|---|---|---|---|---
FWM-2725FBD-S| 25| 79.3(8.1)| 450(450)| 0.3~2| Multiple- varying orifice type
COMMON SPECIFICATIONS
Max Drag N(kgf)| Max Cycle Rate cycle/min| Max Energy
Absorption per min. J/min(kgf ٠ m/mi n)| Extension F
orce N(kgf)| Operating Temp. C˚| Mass g
---|---|---|---|---|---
6370(650)| 60| 539(55)| 27.3(2.78)
or lower
| -5~70| 411
OPTIONAL PARTS
Eccentric angle adaptor OP-010FB
- Screw the eccentric angle adaptor into the main unit until the cap for the eccentric angle and the piston rod form a tight connection. While maintaining this position, fasten the main unit’s nut until it is secured.
- Use the eccentric angle adaptor when the eccentric angle is 2.5° or larger.
- The main unit can also be used as a stopper.
- Use it with a capless soft absorber.
- The maximum operating eccentric angle with an eccentric angle adaptor is ±10°.
- The caps and the guides for inclined use are not unbundled
Note: Material of cap for eccentric angle: Metal
Stopper nut OP-020FB
- Adjust so that it stops 1 mm before the stroke end, and fasten with the main unit’s nut until secured.
Note: When attaching, make sure that the side without a bearing chamfer is the impact surface.
Standard nuts are sold separately as well – M27 Nut
Square flange OP- 040FB
- Once the attachment site is determined, use the main unit’s nut to securely fasten in place.
Liquid-proof cap FWM-2725FBD-C-060
- A drip proof cap is fitted on the unit on delivery.
- Liquid-proof caps are not sold separately.
- Ensure that the cap is facing upward.
If the cap is facing sideways or downward, it cannot provide an effective means for liquid proofing.
Holder with a switch OP-030FB
- Although a holder with a switch can be ordered on its own, we strongly recommend ordering one with the main unit. Please include the main unit’s model number when placing an order.