PRECAUTIONS FOR USE

  • Do not use this product without carefully reading the attached owner’s manual.
  • Ensure that an external stopper (Stopper nut OP-020FB) is also used.
  • Do not turn the oil inlet screw located at the bottom of the main unit.
  • Ensure that sufficient mounting strength is secured for this product. (As a guideline, it should be 2 to 3 times the maximum drag listed in the catalogue.)
  • Do not use this product in a vacuum or a location where it may come in contact with oil.
  • Ensure that an eccentric load is not applied to the soft absorber. (Allowable eccentric angle: within ±2.5°)

ADJUSTMENT METHOD

  • To adjust, turn the adjustment knob located at the bottom of the main unit.
  • Because the adjustment can be done in an analog manner, a value between two integers on the indicator can be set.
  • Once the adjustment is complete, secure with a lock screw using a hex wrench.

ABSORPTION CHARACTERISTICS

Orifice type| Multiple-orifice type| Absorption characteristics
ABSORPTION CHARACTERISTICS
---|---|---
Model number| FWM-2725FBD Series
Application| For medium speed, in particular with a pneumatic cylinder

SPECIFICATIONS

Model| Stroke
mm| Max Energy Absorption J(kgf ٠ m)| Max Equiv.
Mass
kg(kgf)| Range of Impact Rate m/s| Orifice Type
---|---|---|---|---|---
FWM-2725FBD-S| 25| 79.3(8.1)| 450(450)| 0.3~2| Multiple- varying orifice type

COMMON SPECIFICATIONS

Max Drag N(kgf)| Max Cycle Rate cycle/min| Max Energy Absorption per min. J/min(kgf ٠ m/mi n)| Extension F orce N(kgf)| Operating Temp. C˚| Mass g
---|---|---|---|---|---
6370(650)| 60| 539(55)| 27.3(2.78)

or lower

| -5~70| 411

OPTIONAL PARTS

Eccentric angle adaptor OP-010FB

  • Screw the eccentric angle adaptor into the main unit until the cap for the eccentric angle and the piston rod form a tight connection. While maintaining this position, fasten the main unit’s nut until it is secured.
  • Use the eccentric angle adaptor when the eccentric angle is 2.5° or larger.
  • The main unit can also be used as a stopper.
  • Use it with a capless soft absorber.
  • The maximum operating eccentric angle with an eccentric angle adaptor is ±10°.
  • The caps and the guides for inclined use are not unbundled
    Eccentric angle adaptor OP-010FB

Note: Material of cap for eccentric angle: Metal

Stopper nut OP-020FB

  • Adjust so that it stops 1 mm before the stroke end, and fasten with the main unit’s nut until secured.
    Stopper nut OP-020FB
    Note: When attaching, make sure that the side without a bearing chamfer is the impact surface.

Standard nuts are sold separately as well – M27 Nut

Square flange OP- 040FB

  • Once the attachment site is determined, use the main unit’s nut to securely fasten in place.
    Square flange OP-040FB

Liquid-proof cap FWM-2725FBD-C-060

  • A drip proof cap is fitted on the unit on delivery.
  • Liquid-proof caps are not sold separately.
  • Ensure that the cap is facing upward.
    If the cap is facing sideways or downward, it cannot provide an effective means for liquid proofing.
    Liquid-proof cap FWM-2725FBD-C-060

Holder with a switch OP-030FB

  • Although a holder with a switch can be ordered on its own, we strongly recommend ordering one with the main unit. Please include the main unit’s model number when placing an order.
    Holder with a switch OP-030FB