KUKER RANKEN GA-72Cd Magnetic Locator Instruction Manual
- June 4, 2024
- Kuker-Ranken
Table of Contents
- Important Notice
- SECTION 1: OPERATION
- Search Procedure
- APPLICATION NOTES
- Strongly Magnetized Markers
- **When Placing Stakes, Correct Orientation is Important
- Searching Areas along a Chain Link Fence
- Locating Steel Drums
- Additional Applications
- DATALOGGEROUTPUT
- MAINTENANCE
- Troubleshooting Guide
- SERVICE INFORMATION
- SPECIFICATIONS
- LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RANKEN GA-72Cd Magnetic Locator
Instruction Manual
Model GA-72Cd
Magnetic Locator
Manufactured By
Schonstedt Instrument Company 100 Edmond Road
Kearneysville, WV 25430 304-725-1050
Fax 304-725-1095
Web: www.schonstedt.com
E-mail: info@schonstedt.com
Made in USA
Seattle 425-771-7776
Tacoma 253-922-6087
Portland 503-641-3388
Salt Lake City 801-878-9763
Las Vegas 702-586-1152
St. George 702-586-1152
Boise 208-369-4388
www.KukerRanken.com
Preface
The GA-72Cd Magnetic Locator is a product of over 60 years of experience in
producing the world’s finest flux-gate magnetometers and magnetic detectors
for aerospace, military, and civilian applications. The GA-72Cd incorporates
the knowledge obtained from manufacturing under the most rigid quality control
standards. The heart of the GA-72Cd is its patented Schonstedt HeliFlux
magnetic field sensors. These sensors acknowledged to be the world’s finest,
make possible the unequaled performance of our loc-a1to-rs. June 2017
Important Notice
Schonstedt believes the statements contained herein to be accurate and
reliable; however, their accuracy, reliability, or completeness is not
guaranteed.
Schonstedt’s only obligation shall be to repair or replace any instrument
proven to be defective within seven years of purchase. Schonstedt shall not be
responsible for any injury to persons or property, direct or consequential,
arising from the use of any instrument.
SECTION 1: OPERATION
Introduction
The GA-72Cd Magnetic Locator detects the magnetic field of ferromagnetic
objects. It responds to the difference in the magnetic field between two
sensors that are spaced approximately 14 inches apart. This difference is
referred to as the “signal strength” throughout this manual and is represented
in the instrument by an audio tone and visual indication of both signal
strength and polarity. While most objects can be located using either the
audio or visual indication, simultaneous use of both will help you pinpoint a
target and determine its orientation.
Figure 1 illustrates an application in which the locator is used to detect an
iron marker used for property line identification. As shown, the magnetic
field of the iron marker is stronger at Sensor A than it is at Sensor B. As a
result, the frequency of the audio signal is higher than the idling frequency,
40 Hz, which exists when the field strength is the same at both sensors. This
stronger signal also causes the digital indication to peak in either the
positive or the negative direction when the audio signal is at its highest
frequency.
When shipped, the locator is set to provide an audio signal that is heard as
long as the instrument is turned on. If desired, you can change this setting
to an audio signal that is heard only when the instrument is within the
detection range of an object (refer to page 5 of this manual for
instructions).
Turn-On, Sensitivity and Volume Settings
Turn on the GA-72Cd by rotating the On/Off-Sensitivity control knob clockwise
to position 1. This sets the sensitivity to what is referred to as the Normal
Range (the L meter indication). Sensitivity can be increased by rotating the
Sensitivity control clockwise to select M, H, or XH settings (as indicated on
the meter’s GAIN display). Adjust the Volume control for the desired audio
output level.
Battery Level Indication
The meter’s BATT indication displays the batteries’ voltage level. When all four segments are black, the voltage level is between 100% and 25% (up to 40 hours of operation with intermittent usage). As the voltage decreases, the number of black segments decreases. Battery life varies with usage and the ambient temperature. Cold temperatures reduce battery life. Low temperatures may result in only two or three segments being black; this could be temporary and all segments will change back to black as the temperature increases.
Audio Output Selection
All GA-72Cds are shipped from the factory with the Audio Output Switch set to
“B”; this setting provides an audio signal that is always present. If you
prefer to not hear a signal until the locator is within the detection range of
a target, set the switch to “A”.
Audio Signal with Output Switch set to “A”
No audio signal is heard until the GA-72Cd comes within the detection range of
a ferromagnetic object. The locator will increase in volume over the object.
It will decreases in volume and turn off when the locator is moved out of
range.
NOTE: If you put the GA-72Cd down without turning the Sensitivity/Power switch
to Off, the “power-on monitoring feature” (designed to conserve battery life)
will initiate a beeping audio-alert signal after 15 seconds.
Audio Signal with Audio Output Switch set to “B”
As you move the GA-72Cd across a ferromagnetic object, the 40 Hz idling
signal, which is always present, increases in frequency, peaks when the
locator is directly over the object, and then decreases to 40 Hz.
Regardless of which switch setting, the indication of signal strength and the
polarity on the meter will always peak (positive or negative) when the locator
is directly over a ferromagnetic object.
As shown in Figure 4, the cover must be removed to change the setting of the
Audio Output Switch.
Search Procedure
Set the On/Off-Sensitivity control for L and grasp the locator as illustrated
in Figure 5. Because the upper sensor is located near where the locator is
usually held, wrist watches may produce unwanted changes in the audio signal
and in the meter indications. Remove your wristwatch or hold the locator in
the other hand. Keep the locator away from your shoes; shoes may contain
magnetic material.
To obtain the maximum area of coverage, the locator should be swept from side
to side. When the locator comes within range of an iron object, the audio
signal will peak, the bar graph will expand positive or negative, and the
digital readout will peak.
Figure 5: Searching With the Locator
When the GA-72Cd is positioned directly over a vertical pipe, the audio and
digital indications will peak. The expanding bar graph and digital readout may
display either a positive or a negative level.
The audio signal, bar graph, and digital indications peak over each end of a
horizontal pipe. One end is positive; the other end is negative. This will
help you to distinguish between two vertical pipes or one horizontal pipe.
Usually, two vertical pipes buried in close proximity will produce digital
indications with the same polarity.
APPLICATION NOTES
Basic Signal Patterns After you have detected the presence of a target,
hold the locator vertically and slowly move it back and forth in an “X”
pattern while observing the digital readout. The value of the number will be
highest when the locator is directly over a vertical target or over the ends
of a horizontal target. The “X” pattern, as shown in Figure 8, is ideal for
pinpointing small objects. By using this technique, a 1-1/4 inch PK nail
buried up to 8 inches can be precisely located.
If you are looking for a corner marker and detect two more signals in the same
general area, raise the locator several inches above the ground or reduce the
sensitivity setting. Any signal that disappears when the locator is held
higher or when the sensitivity is decreased is probably coming from a shallow
target. As shown in Figure 9, the signal from a rusty bolt or other small item
decreases much faster with distance than the signal from a larger target, such
as an 18-inch length of 3/4 rebar that can be located at depths up to 7 feet.
Strongly Magnetized Markers
A strongly magnetized marker that is at or near the surface will provide a
weaker indication on both sides of the marker, and this can be mistaken for
the actual marker.
The heavy line in Figure 10 represents the increase and decrease in the audio
and digital indications as you move the locator over a marker. Between points
A and B, the signals increase slightly and then decrease. Just beyond B, the
signals increase rapidly, peak directly over the marker, and then decrease at
point C. From C to D, the signals increase and decrease again. Therefore, if
you do not move the locator completely across the marker, you may assume that
the weaker indication on either side of the marker is its location.
The two weaker indications on both sides of the actual marker occur because the locator is extremely sensitive to the magnetic field components parallel to its long axis. At point B and C, the field is perpendicular to the locator so no peak audio or digital indications are produced.
**When Placing Stakes, Correct Orientation is Important
**
For checking purposes, the orientation of the pin relative to the locator is
shown in Figure 11. Check the pin with one orientation. Then rotate the pin
180°. The orientation that gives the largest reading is the one that should be
used. This reading will be positive in the Northern Hemisphere and negative in
the Southern Hemisphere (Australia, New Zealand, etc.)
An iron pin has two types of magnetization. One is the magnetization induced
by the Earth’s magnetic field. The induced magnetization is always downward in
the Northern Magnetic Hemisphere and produces a positive output no matter
which end of the stake is driven into the ground. The other type of field is
the permanent magnetization that is fixed to the pin. For maximum detection,
the stake should be driven into the ground so that the permanent magnetization
is in the same direction as the induced magnetization.
Locating Manholes, Septic Tanks and Well Casings
The magnetic field is strongest at the edge of a shallow manhole cover. You
can easily trace the edges of covers near the surface. The locating depth for
manhole covers ranges up to 8 feet.
The great length of a good casing provides a strong field at the surface that
makes it easy to locate casings buried up to 15 feet deep.
The GA-72Cd can be used to precisely locate the metal handles or reinforcing
bars on septic tank covers at depths up to 4 feet.
Locating Objects under Snow or Water and Tracing Barbed Wire
The locator can be used in snow or in flooded areas – just keep the electronic
unit out of the snow or water.
Locating and Tracing Barbed Wire
You can often trace the barbed wire from old fence lines buried just beneath
the surface. Even if the wire is only a trail of rust, it can still be
detected near the surface. Tip the locator a little lower than usual (but not
parallel with the ground).
Examine trees for benchmarks and bits of embedded barbed wire. Then hold the
locator parallel to the direction of the wire.
Searching Areas along a Chain Link Fence
Searching in the vicinity of a chain link fence requires a reduced sensitivity
setting and some control over the orientation of the locator. As illustrated
in Figure 17, position the locator horizontally with its long axis
perpendicular to the fence. This ensures that the upper sensor is kept away
from the fence.
Perform the search by slowly moving the locator forward along the fence while
also moving it to the right and to the left. As you move forward, this
technique will allow you to search an area several feet wide. Listen for an
abrupt drop in the signal (as shown by the null in Figure 18) that will occur
when the lower sensor, located 1-5/8 inches from the end of the locator, is
directly over the stake. Any variation in the position of the locator will
produce an abrupt rise in the frequency of the signal. Locating Valve
Boxes
Both the valve and its casing, when iron, provide strong magnetic fields that
make them easy to locate. Plastic enclosures containing magnets are easily
located at depths of 6 feet or more. Figure 19: Locating Valve Boxes and
Casings
Locating Cast-Iron Pipes
As illustrated in Figure 20, cast-iron pipes produce the strongest magnetic
signals at their joints.
The initial search should be performed as follows:
- Set the Sensitivity control for maximum (XH indication).
- Hold the locator vertically and approximately 1 to 1-1/2 feet above the surface.
- Walk without turning or tilting the locator.
- Mark the locations where the maximum signal levels occur.
- Return to an area of maximum signal strength and hold the locator several inches above the surface. The sensitivity will probably have to be reduced during this second pass. Four-inch pipes can be located at depths up to 8 feet.
Locating Steel Drums
As shown in Figure 21, the GA-72Cd’s signal pattern will vary depending on the vertical or horizontal orientation of the drum and how deep it is buried. A 55 gallon drum can be located at depths up to 8 feet.
Locating Ordnance and Weapons
The versatile, lightweight, cost-effective GA-72Cd is also designed to aid EOD
technicians and law enforcement officers during area search operations.
Figure 22: Basic Signal Patterns from Vertical and Horizontal Targets Help to Determine Target Orientation
Additional Applications
- The military and many local and state police departments use the GA-72Cd to detect buried ordnance and discarded weapons.
- People drilling in an area where hazardous materials might be encountered should use the GA-72Cd to search the area prior to drilling.
Other Notes
- A burbling sound indicates the presence of an energized power line. This will not influence the meter indication unless associated with a magnetic structure.
- The instrument will not respond to non-ferrous metals such as gold, silver, copper, brass and aluminum.
DATALOGGEROUTPUT
The headset jack also provides an analog output signal for input to a data logger. This +/-4 volt signal varies in proportion to signal strength and is accessible by wiring a standard stereo plug.
MAINTENANCE
The GA-72Cd is designed and built to give trouble-free operation. Normally,
maintenance is limited to the occasional replacement of the batteries. In the
event a malfunction does occur, refer to the Troubleshooting Guide on page 18.
Replacement of Batteries
The GA-72Cd is powered by two 9-Volt alkaline batteries. Access to the
batteries is obtained by loosening the four captive screws and removing the
electronics cover (as shown in Figure 29). It is recommended that you purchase
spare batteries for this unit. When you use the spare batteries, replace them
as soon as possible so that you will never be without batteries in the field.
Troubleshooting Guide
Symptoms | Possible Cause | How to Check | How to Fix |
---|---|---|---|
Dead | Dead Batteries |
Batteries not making contact
Battery leakage| Replace
Check for contact corrosion
Remove| Clean contacts
Return unit to factory
Intermittent| Batteries not making good contact| Check for corrosion| Clean
contacts
Uncontrollable screaming| Weak batteries| Replace| ——
SERVICE INFORMATION
If your locator needs service, please return it to the factory with the following information: Name, Address, Telephone and Fax Numbers, Email Address, Where Purchased, Date of Purchase, and Description of Trouble(s). An estimate will be provided prior to service work being done. See shipping information below:
FOR SERVICE OR REPAIR
Please ship the locator (in its case) to:
Schonstedt Instrument Company 100 Edmond Road
Kearneysville, WV 25430
SPECIFICATIONS
(Specifications subject to change without notice)
Input Power: ………………………… Supplied by two alkaline 9-V batteries**
Battery Life: …………………………. 40 Hours (intermittent usage)
Output:
Audio
Output Option ……….. Signal increases or decreases in volume Switch at “A” with
gradient-field intensity
Output Option ……….. Signal increases or decreases in frequency
Switch at “B” with gradient-field intensity
Visual …………………………. Digital readout expanding bar graphs indicate polarity
(positive or negative) and relative strength of the magnetic field
Battery Check: ……………………… BATT 4-segment LCD
Weight: ……………………………….. Approximately 2.5 lbs. (1.14 kg)
Operating Temperature: ……….. -13° to 140°F (-25° to 60°C)
Overall Length: …………………….. 34.5 in. (87.6cm)
Waterproof Length:………………. 21 in. (53.3cm)
Nominal Sensor Spacing: ……….. 14 in. (35.6cm)
Construction: ……………………….. Rugged, all solid state
**Units prior to SN: 339698 it is recommended to use Lithium batteries. Using
Alkaline batteries in these units will produce a magnetic field that will
impact the performance of the locator (especially when set to the H or XH
sensitivity range).
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Application of Council Directive(s): 2004/108/EC Standard(s) to which
Conformity is Declared: EN 61000-6-1:2001, EN61000-4-2, EN61000-4-3, EN
61000-6-3:2004, EN55022:1998 with Amendment A1:2000 (CISPR-22)
LIMITED WARRANTY
Schonstedt Instrument Company (Schonstedt) warrants each product of its
manufacture to be free from defects in material and workmanship subject to the
following terms and conditions. The warranty is effective for 7 years* after
the shipment by Schonstedt to the original purchaser. Please complete the
warranty registration card and send back to Schonstedt Instrument Company.
Schonstedt’s obligation under the warranty is limited to servicing or
adjusting any product returned to the factory for this purpose and to
replacing any defective part thereof. Such product must be returned by the
original purchaser, transportation charges prepaid, with a description of the
defect in writing. If the fault has been caused by misuse or abnormal
conditions of operation, repairs will be billed. Specifically, this warranty
does not cover product that has been subject to inundation by fire, water or
another liquid intrusion or units that have been damaged or compromised due to
repair, alteration or modification by anyone other than an authorized repair
representative. Prior to a repair being performed by Schonstedt, a cost
estimate will be submitted and no work will be completed until authorized by
the customer. Batteries are specifically excluded under the warranty and
should be addressed to the manufacturer of the batteries in question.
Schonstedt shall not be liable for any injury to persons or property or for
any other special or consequential damages sustained or expenses incurred by
reason of the use of any Schonstedt product.
- For Military &EOD applications, the warranty is 1 year.
GA-72Cd Repair Parts
Item No | Part Number | Description |
---|---|---|
1 | K20015 | Knob, Pointer |
2 | K20013 | Knob, Round |
3 | 208306 | Battery Board Assy with Cable |
4 | 208282 | Captive Screw (4 Req’d) |
5 | SS208195 | Tip, Crutch |
6 | 208345 | Potentiometer Assembly |
7 | 208323 | Gasket, Base |
8 | IC8511000487* | LCD / Meter |
9 | S35080* | Switch, On/Off/Sensitivity |
10 | 208317 | Battery Chassis Assembly |
11 | 208348 | Cover & Handle Assembly |
12 | SMVIN6C500W‐NPH30006 | Screw, #6‐32 x ½” (2 Req’d) |
13 | 302145 | headset (Optional) |
14 | B11013 | Case, Carrying |
15 | 208349 | 9V Alkaline Battery (2 Req’d) |
16 | B15002* | Interface Cable Assembly |
17 | L55002‐1 | Buzzer, Piezo |
18 | L55002‐2 | Latch |
19 | 207220 | Latch Keeper |
20 | J10014* | |
21 | End Cap |
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>