RAIN BIRD ESP-9V Battery Operated Controller User Manual
- June 8, 2024
- RAIN BIRD
Table of Contents
- RAIN BIRD ESP-9V Battery Operated Controller
- Introduction
- Operation and Setup
- Set Date & Time
- Set Irrigation Schedule
- Set Zone Watering Start Times
- Set Zone Watering Days
- Watering Day Options
- Odd Days I Even Days
- Special Features
- Contractor Default Save
- Factory Default Restore
- Rain Sensor Bypass
- Installation
- VALVE WIRING
- Batteries
- Optional Rain Sensor
- Troubleshooting
- Certifications
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RAIN BIRD ESP-9V Battery Operated Controller
Introduction
Thank you for choosing Rain Bird’s E5P-9V Battery-Operated Controller. The ESP-9V is designed to provide worry-free automatic Irrigation In the absence of AC power or in areas where installing new field wires is not practical.
Operation and Setup
Contractor Rapid Programming™
At initial programming, the controller automatically copies the start times and watering days from Zone 1 to all other zones.
- NOTE : If multiple zones have the same or overlapping watering times, the controller will water the zones in sequence (multiple zones will not run at the same time).
- NOTE : Changes to a zone’s schedule made after Initial programming will only affect the zone being modified.
- NOTE : You may re-activate the Contractor Rapid Programming™ feature by resetting factory defaults.
Set Date & Time
Press the MODE button untlltheSet Date& Time screen is displayed.
- Press + or – to set the time format (12 hour or 24 hour);then press I►
- Press + or -to set the hour (ensurethatAM/PM setting is correct when using 12 hour format); then press I► to set the minutes; then press
- Press + or – to set the year (YYYY); then press ► I► to set the day (D), then month (M). If 12 hour format is selected, the date format will be shown as M/DNYYY.
Set Irrigation Schedule
Prass the MODE button until ffl• Set lrrl,atlon Sch•dul• scrun U displayed.
Select Zone
Press + or – to select the Zone Number; then press I►
Set Zone Watering Run Times
Press + or – to set the Run Time (In minutes); then press I►
NOTE : RunTimes can be set between 1 to 240 minutes.
Set Zone Watering Start Times
- Press + or – to set the 1 st Start TI me for the selected Zone (set to 06:00 by default]; then press I►
- Press + or – to set the next Start Time, or press I► again to advance to Set Watering Day
REPEAT to set additional StartTimes, up to six for that Zone.
NOTE : Adjustments are set In 1 0 minute increments.
NOTE : To remove a Start Time, press + or – until -:- (OFF] is displayed.
(-:- is just before 0:00 or 1 2:00 AM.)
NOTE : The controller will not water multiple zones at the same time. If
two or more zones have the same (or overlapping) start times, the controller
will wait until the first zone Is finished watering before starting the rest
of the zones in sequence. This method is called “start time stacking
Set Zone Watering Days
Custom Days
- Press + (to enable) or – (to disable) the blinking Selection Day. The cursor will automatically advance to the next Selection Day.
- REPEAT to set each day of the week as desired.
- REPEAT Steps 1 -4 for additional Zones as desired.
- When programming is complete, press the MODE button until the AllTO RUN screen is displayed
Watering Day Options
Additional Watering Day options are also available:
- Cytlic Days {1 -30]
- Odd Days (Will NOT water on the 3 1 st of the month)
- Even Days
Tochangeazone’swateringdaytype,simplypressthe + and-buttons at the same time while setting Zone Watering Days.
Cyclic Days
- Press + or – button to set the number of days in the watering cycle;then press I►
- Press + or-to set the next Watering Day; then press I►
Odd Days I Even Days
When ODD 1,3,5 ••• 29 (or EVEN 2;4,6….30) is blinking, press I►
NOTE : ODD schedules will not water on the 31st of the month
Auto Run
Press the MODE button until th• AUTO RUN screan 11 displayed.
In AUTO RUN mode, the ESP-9V wlll irrigate each zone per its programmed
schedule. If any zones are scheduled to run at the same time and day, your
controller will place those zones in a queue and irrigate one valve at a time,
starting with the lowered number zone first
NOTE : After 5 minutes of inactivity, the controller will revert to AUTO
RUN mode (unless the controller is in OFF) and tum off the display. Press any
key to tum the display back on
Off
Press the button until the OFF screen is displayed.
Selecting the OFF mode will cancel any active watering and prevent any irrigation from starting automatically
- NOTE : Select the AUTO RUN mode to resume normal operation. Programmed irrigation schedules will NOT run if the controller is left in OFF mode.
- NOTE : If you intend to stop automatic irrigation only for a few days, we suggest you use the”DelayWaterlng# feature described In page 1 0.
- NOTE : To re-initiate watering, press the button again to return to AllTO RUN mode
Manual Watering
Press the button until the Manual Watering screen is displayed.
- Press + or – to select ALL Zones or ONE zone; then press I►
- Press + or – to set the RunTimeforthe selected Zones; then press I► to begin watering
NOTE : To water the scheduled runtime for each zone: Press – when setting manual runtime until the screen shows “SCH”MIN.
One-touch Manual Start
Water ALL zones Immediately according to their previously scheduled run times:
With the controller in AUTO RUN mode, press and hold I► for 3 seconds to begin
watering all zones that have a programmed runtime
Seasonal Adjust
Prass the MODE button until the Seasonal AdJust screen Is displayed
The SEASONAL ADJUST mode allows you to increase or decrease the run times for
all zones by a certain percentage (1 0% to 200%).
Press + or- to increase or decrease the setting.
NOTE : SEASONAL ADJUST applies to ALL automatic watering.
Special Features
Delay Watering
Delay automatic irrigation for up to I days.
Press the MODE button until the AUTO RUN screen is displayed. (Unit must NOT
be watering.)
- Press and hold + for 3 seconds, then press + or – to select the number of DAYS to delay irrigation, up to 9 days.
- To cancel, press – until DAYS is set to O. (Controller will revert to AllTO RUN.)
SYMBOL and DAYS remaining are displayed while Rain Delay is in effect.
Contractor Default Save
Save irrigation schedules for future retrieva1
- Press the button until the OFF screen is displayed.
- Press and release both ‘6 and + buttons at the same time.
- The “OFF symbol will flash briefly to confirm schedules are saved.
Contractor Default Restore
Restore previously saved irrigation schedules
- Press the button until the OFF screen ls displayed.
- Press and release both + and I► buttons at the same time.
- The “OFF symbol will flash briefly to confirm schedules are restored
Factory Default Restore
Restore the controller’s factory default settings.
CAUTION
All programmed irrigation schedules currently stored in memory will be lost.
However, Contractor Default settings remain stored in separate memory and are
not affected by Factory Default Restore, and can be recalled after restoring
Factory Defaults.
- Press the MODE button until the Seasonal Adjust screen Is displayed.
- Press and release both )i; and I► buttons at the same time.
Rain Sensor Bypass
Set sensor to Active or Bypass for all zones.
- Press the MODE button until the AUTO RUN screen Is displayed.
- Press and release both – and I► buttons at the same time to toggle between OBEY and IGNORE.
- SYMBOL is displayed when IGNORE is selected. Sat sensor to Actiw or Bypass for any Individual zone.
- Press the MODE button until the Set Irrigation Schedule screen is displayed.
- Press + or – to select the desired zone.
- Press and release both – and I► buttons at the same time to toggle between OBEY and IGNORE.
- SYMBOL is displayed when IGNORE is selected
Installation
Valve Wiring
Wires may be extended upto 100 feet {30 meters) {18 AWG I 0.75 mm2 minimum
wire size) from the controller.
All wire connections should be made using appropriate water-proof splice kits
(not provided).
- Attach the black wires from each solenoid to the black (common) wlre(s) on the ESP-9V.
- Attach one red wire from each solenoid to the appropriate zone wire on the ESP-9V.
- Connect an optional Master Valve.
VALVE WIRING
NOTE : The ESP-9V can be mounted on a DC latching solenoid using the included solenoid bracket, or on a wall using the optional wall-mount bracket (Model: 9VMOUNT)
Batteries
The Rain Bird ESP-9V uses two alkaline 9-Volt batteries to operate. Your controller will function using either one or two 9-Volt batteries. Under normal conditions, the expected life ls 1 year for a single battery and two years when using two 9-Volt batteries.
Replacing Batteries
- Remove the battery compartment cap.
- Install one or two 9-Volt alkaline batteries on the battery clips provided.
- Re-install the battery compartment cap.
NOTE : Do not mix new batteries with old ones. Doing so could reduce the battery life and cause the controller to stop working prematurely.
Optional Rain Sensor
-
Cut the yellow loop in half and remove about 1 /2″of insulation.
NOTE : Cut the yellow wire loop only when installing a rain sensor. -
Connect the sensor to the terminals with waterproof connectors.
BACK OF CONTROLLER
Troubleshooting
Problem | Possible Clluse | Possible Solution |
---|---|---|
No Display | Display is in sleep/power save | |
mode. | Press any key to wake up display. | |
Batteries are dead. | Replace batteries. | |
Automatic Irrigation not starting | Missing start **time, | |
run time or watering day,.** | Set start time, run |
time and watering days.
Sensor wire loop cut but no rain sensor
installed.| Re-connect the sensor wires or bypass
the sensoroperation.
Rain Delay is set.| De-activate rain delay.
Automatic Irrigation started but no water- Ing
o”ur1| No water pressure.| Turn on main water
supply.
Faulty wiring.
Faulty Solenoid.
| Check for open/short circuits in wiring.
Replace solenoid.
Incompatible Solenoid.| Must use a 9V-latching
solenoid (Rain Bird 1 <80920) or other compatible DC
latching solenoid.
Controller is watering morathan u:pactad| Excessive
StartTimes, Run Times or watering days.| Modify StartTimes, Run
Times or Watering Days as desired.
Seasonal adjust set| Reduce the seasonal adjust
value as needed.
“Manual watering ALL” Is not watering
some zones or Isn’t availabl• as an option
| One or more zones don’t have a pro- grammed start time or run time.| Program a start time and Nn time for all desired zones.
Certifications
Oeclaration of Conformity
- Rain Bird Corporation hereby declares that the following irrigation controllers are CE compliant
- Models: WPX6, WPX1, WPX2, WPX4, WPX1 SOL, WPX1 BSP, WPX1 SLIP
- The object of the declaration described above is in conformity with the relevant Union Harmonization Legislation:
- 201 4/30/EU Electromagnetic Directive (EMC)
- References to the relevant harmonized standards used or references to the other technical specifications in relation to which conformity is declared are listed below:
- EN 61 000-6-1 :2007, EN 61 000-6-3:2007
- The products submitted meet the requirements of IP68:
- EN 60529:1 991 / Al :2000 / A2:2013
- This declaration of conformity is issued under the sole responsibility of the manufacturer.
Full Name : Ryan Walker
Position : Director
Date : July 1 8th, 201 9
Rain Bird Corporation 970 W. Sierra Madre Azusa, CA 91 702 U.S.A (626) 81
2-3400
Rain Bird Corporation 970 W. Sierra Madre Azusa, CA 91 702 U.S.A (626) 81
2-3400
Rain Bird Europe Pare Clamar Bat A. 1 3792 Aix en Provence Cedex 3, France +33
(0)4 42 24 84 48
Technical Services for United States and Canada Only 1 -800-RAI N Bl RD
www.rainbird.com
NOTICE
Changes or modifications not expressly approved by Rain Bird could void the user’s authority to operate the equipment
Waste Electrical and Eledronic Equipment (WEEE)
As a hardware manufacturer, Rain Bird has met its national obligations to the EU WEEE Di rective by registering in those countries to which Rain Bird is an importer. Rain Bird has also elected to join WEEE Compliance Schemes in some countries to help manage customer returns at end of life
® Registered trademark of Rain Bird Corporation © 2021 Rain Bird Corporation P/N: 690832-01 Rev. 01 DE21
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>