ODYON proWE20-24 Receiver 2-Channel Max Range Instruction Manual
- June 8, 2024
- ODYON
Table of Contents
proWE20-24 Receiver 2-Channel Max Range
Instruction Manual ODYON pro WE20/24
ODYON pro WE40/24
ANLEITUNG
INSTRUCTION MANUAL
proWE20-24 Receiver 2-Channel Max Range
Fig. 1
Note: Only channel 1 is described here, the mode of operation is identical
for each channel and each channel has its own button, its own selector switch
for the operating mode and its own LEDs (red, green, orange).
1 = Wall receiver
2 = LEDs channel 1 (red, green, orange)
3 = Channel 1 button
4 = Operating mode selector switch
5 = Repeater LEDs (red, green)
6 = Repeater button
7 = Internal antenna
8 = External antenna connection
9 = Connection terminal inputs
10 = Cable entry
11 = Connection terminal output
12 = Connection terminal supply voltage
Cable gland PG9
Model:
ODYON pro WE20/24 (2-channel)
ODYON pro WE40/24 (4-channel)
Thank you for purchasing this wall receiver from the ODYON pro series. This
wall receiver has been designed for excellent functionality and offers perfect
performance and solution possibilities. The essential design guarantees
maximum ergonomic comfort and clear functional operability.
The ODYON pro wall receiver with 2 or 4 channels offers potential-free
switchover contacts and can control up to 2 functions of one or more other
ODYON pro receivers. Radio ranges of several hundred metres can be achieved,
depending on the environment and constellation of the radio system. An
external antenna can be used to increase the radio range.
The toggle contact offers 3 operating modes to switch either each time a
button is pressed on the remote control (toggle) or while the button on the
remote control is held (push). In addition, it is also possible to teach two
buttons of a remote control to be able to switch ON and OFF selectively.
This wall-mounted receiver can also be used as a repeater for other units of
the ODYON pro series to further increase the radio range.
**** The wall-mounted receiver ODYON pro WE10/24 can switch 230V mains
voltage and may only be installed by a qualified electrician.
A maximum of 16 channels can be taught-in to one wall receiver. Each function
key of a hand-held transmitter corresponds to one channel.
GENERAL INFORMATION ON RADIO OPERATION
The radio transmission is realised on a non-exclusive transmission path, which
is why interference cannot be ruled out. Further interference can be caused by
switching operations, electric motors or defective electrical appliances. The
radio range in buildings can deviate greatly from that in the free field.
Apart from the transmitting power and the receiving characteristics of the
receiver, environmental influences such as air humidity play an important role
in addition to structural conditions on site. The ODYON pro series is designed
for radio ranges of several hundred metres under optimal conditions. However,
the maximum radio range is only achieved with visual contact between
transmitter and receiver and without high-frequency interference.
Possible causes for reduced radio range are:
- Buildings of any kind or vegetation influence the radio range
- The distance of the antenna to the body, as well as to other conductive surfaces or objects
- The “background noise” in non-rural areas can already be relatively high, reducing the signal-to-noise ratio and thus the radio range
- Similarly, it is not impossible that devices with similar operating frequencies may be operating in the neighbourhood, making the receiver seemingly less sensitive
- If the receiver is in the vicinity of poorly shielded devices that produce interfering radiation (e.g. PCs), the radio range may also be severely reduced
- If the repeater function is used, there may be a slight delay before the receiver responds to the remote control
OPTIONAL ACCESSORIES
Rod antenna with magnetic base
Screw antenna
ODYON hand-held transmitter (1-, 2-, 4-channel)
SCOPE OF DELIVERY
ODYON pro WE20/24
1x 2-channel wall receiver
3x cable entry
1x blind plug
1x manual
ODYON pro WE40/24
1x 4-channel wall receiver
5x cable entry
1x blind plug
1x manual
COMMISSIONING AND OPERATION
** The wall-mounted receiver ODYON pro WE10/24 can switch 230V mains
voltage and may only be installed by a qualified electrician.
Communication between handheld transmitter and wall receiver
If the wall receiver receives a signal from a remote-controlled hand-held
transmitter, the switching contact is switched according to its setting and
the receiver sends a feedback signal to the hand-held transmitter, whose
control LED indicates this by flashing red/green.
Connection of operating voltage
Make sure that all connection lines are voltage-free and connect the
connection line to the connection terminal (13). This wall receiver can be
operated with an operating voltage of 12V to 24V AC or DC. The polarity does
not need to be observed.
Connecting the units to be switched
Fig. 2 shows two examples of how a device to be switched can be connected to
the “Output” connection terminal. These are potential-free change-over
contacts, i.e. as long as the relay is not switched (orange LED of the
corresponding channel is not lit), the screw terminals COM and NC are
connected. If the relay is switched (orange LED of the corresponding channel
lights up), COM and NO are connected.
Each contact may be loaded with max. 5A at 230VAC.
NC= Normally Closed (contact closed when relay is not switched)
NO= Normally Open (contact open when relay is not switched)
COM = Common contact
Input connection
At the “Input” connection terminal (9) you have the option of connecting e.g.
2 push-buttons in order to use the wall receiver like a 2-channel hand-held
transmitter. For this purpose, a potential-free contact (e.g. a simple push-
button) can be connected to the two screw terminals “IN1”. Another push-button
can be connected to the screw terminals “IN2”.
If one of the push-buttons is pressed, the wall receiver sends a radio signal
which can be taught-in to another receiver. The wall receiver can thus also be
used to create a stationary 2-channel transmitter.
The buttons must not be operated at the same time.
** Once everything has been connected and checked, the power supply can be
switched on/set up.
Operating Mode Switching Contact / Teaching in Hand-held Transmitter
The switching contact offers 3 different operating modes in order to be able
to be used as versatilely as possible.
“2-Channel” operating mode
Slide the selector switch (4) for the operating mode to the “2-channel”
position according to the labelling on the circuit board. Press the key (3)
for the corresponding channel; the red and green LEDs of the channel now light
up. Then press two buttons on the hand-held transmitter in succession, e.g.
button 1 and 2. The LEDs flash once each to confirm and then go out.
Now the switch contact is switched ON when the first key (1 in the example) on
the hand-held transmitter is pressed and switched OFF when the second key (2
in the example) on the hand-held transmitter is pressed.
The orange LED from the channel lights up when the relay is switched ON.
“Toggle” operating mode
Slide the selector switch (4) for the operating mode to the “Toggle” position.
Press the button for the corresponding channel (3), the LEDs for the channel
light up red
and green, and then press the desired button on the hand-held transmitter. The
LEDs flash once for confirmation and then go out.
The contact switches every time the corresponding button on the hand-held
transmitter is pressed. The orange LED from the channel lights up when the
relay is switched ON.
“Push” operating mode
Slide the operating mode selector switch (4) to the “Push” position. Press the
button (3) for the corresponding channel, the LEDs of the channel light up red
and green, and then press the desired button on the hand-held transmitter. The
LEDs flash once for confirmation and then go out. When the button on the hand-
held transmitter is pressed, the contact switches ON as long as the button on
the hand-held transmitter is pressed and OFF when the button on the hand-held
transmitter is released.
NOTE: You can switch between the “Toggle” and “Push” operating modes at
any time. If the “2-channel” mode is to be or has been set, the wall receiver
must be reset as described in the next section. Afterwards, all transmitters
must be relearned.
Repeater function
This wall receiver can also be used as a repeater. Briefly press the repeater
button (6) and then the button on the hand-held transmitter that is to be
forwarded. Position the wall receiver to be used as a repeater so that it has
radio contact with the wall receiver to which it is to forward the signal. As
soon as the wall receiver used as a repeater receives a taught-in signal, it
waits briefly to see whether the target receiver has already sent an
acknowledgement. If this is not the case, the repeater forwards the signal and
then also waits for the feedback from the target receiver and then forwards
this to the hand-held transmitter.
Coding
The wall-mounted receiver is coded at the factory with a permanently assigned
and unique serial number for identification purposes for transmission
operation (button on the inputs). For security reasons, this cannot be changed
and allows many combinations of the radio system. The serial number is
transmitted encrypted in the radio protocol and therefore cannot be copied.
To teach in a hand-held transmitter to an ODYON pro receiver, press the
channel button (5) on the receiver and then press the desired button on the
hand-held transmitter. After the hand-held transmitter has been successfully
tuned in, the receiver switches according to the set operating mode. Read the
section “Switching the operating mode” for more detailed information.
If another wall receiver is to be used as a transmitter, press the
corresponding button connected to the input of the wall receiver used as a
transmitter instead of the button on the remote control.
Reset (delete transmitter)
To reset the wall receiver and delete all taught-in transmitters, press and
hold one of the channel keys or the Reapeater key, the red and green LEDs will
light up in sequence. When the red and green LEDs of each channel and the
repeater light up, release the button. The LEDs flash 3 times for
confirmation. The wall receiver is now reset and the transmitters can be
relearned.
If you release the button before all LEDs are on, the reset process is
cancelled and the tuned-in transmitters remain stored.
NOTE: It is not possible to delete only one transmitter.
TECHNICAL DATA
Radio frequency: 869.5 MHz
Transmitting power: < 100mW
Power supply: 12V – 24V AC or DC; approx. 1W
Switching contact: max. 230V, 5A
Operating temperature: -20° – + 65°C (storage -40° – + 75°C)
Housing dimensions: 160 mm x 110 mm x 90 mm (Subject to technical changes!)
MAINTENANCE AND CLEANING
The product is maintenance-free. Leave any repairs to a specialist. Clean the
product with a soft, clean, dry and lint-free cloth. Do not use any cleaning
agents containing solvents, as this may damage the plastic housing and any
labelling.
Disposal instructions
Do not dispose of the wall receiver in household waste! Electronic devices
must be disposed of in accordance with the directive on waste electrical and
electronic equipment via the local collection points for waste electronic
equipment.
2-YEAR LIMITED WARRANTY
This product is warranted to be free from defects in materials and workmanship
for a period of 2 years from the date of purchase. This applies only if the
appliance is used in the usual manner and is regularly maintained. The
obligations of this warranty will be limited to the repair or re-installation
of any part of the unit and will only apply on condition that no unauthorised
modifications or attempted repairs have been made. Your statutory rights as a
customer are in no way affected by this warranty.
Please note!
There is no entitlement to warranty in the following cases, among others:
– No proof of warranty
– operating errors
– Incorrect coding/channel selection
– Interference from other radio equipment (e.g. mobile phone operation)
– External interference/impacts
– Mechanical damage
Limitation of liability
The manufacturer shall not be liable for loss or damage of any kind, including
incidental or consequential damages, resulting directly or indirectly from the
malfunction of this product.
SAFETY INSTRUCTIONS
Damage caused by failure to observe these operating instructions will
invalidate the warranty. We accept no liability for consequential damage! We
accept no liability for damage to property or personal injury caused by
improper handling or non-observance of the safety instructions. In such cases,
any warranty claim becomes invalid!
Do not use this product in hospitals or other medical facilities. Although
this system emits only relatively weak radio signals, these could cause
malfunctions of life-support systems there. The same may apply in other areas.
For safety and approval (CE) reasons, unauthorised modification and/or
alterationof the product is not permitted.
Do not leave the packaging material lying around carelessly; plastic films/
bags, polystyrene parts, etc., could become dangerous toys for children. These
operating instructions are a publication of m-e GmbH modern-electronics
An den Kolonaten 37
26160 Bad Zwischenahn
These operating instructions correspond to the technical status at the time of
going to press. We reserve the right to make changes in technology and
equipment.
Status: 24/11/21
Hiermit erklärt die m-e GmbH modern-electronics, dass dieses
Gerät den folgenden Richtlinien entspricht:
RoHS 2011/65/EU
RED 2014/53/EU
Die KONFORMITÄTSERKLÄRUNG kann unter folgender Adresse abgerufen werden:
http://www.m-e.de/download/ce/op-we20-40-230ce.pdf
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>