Ring Keypad 4AK1S70EN0 Manual
- June 8, 2024
- Ring
Table of Contents
- Ring
- Ring Keypad
- SKU: 4AK1S70EN0
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Battery Report Interval
- Parameter 10: Key Tone Volume
- Parameter 11: Ambient Light Sensor Level
- Parameter 12: Siren Volume
- Parameter 13: Proximity On/OFF
- Parameter 14: Proximity Distance
- Parameter 15: Extended Battery Life LED Brightness Adjustment
- Parameter 16: Reduced Battery Life LED Brightness Adjustment
- Parameter 17: Fast Blink Rate
- Parameter 18: Slow Blink Rate
- Parameter 2: Z-Wave Sleep Timeout
- Parameter 3: Co-Proc Is Alive
- Parameter 4: Proximity Timeout
- Parameter 5: Button Press Timeout
- Parameter 6: Status Change Timeout
- Parameter 7: Power Mode
- Parameter 8: Key Backlight Timeout
- Parameter 9: Key Backlight Brightness
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Ring
Ring Keypad
SKU: 4AK1S70EN0
Quickstart
This is a
secure
Entry Control Keypad
for
U.S. / Canada / Mexico.
Please make sure the internal battery is fully charged.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Ring Protect features a Z-Wave keypad,will act as an arming station for the Ring Protect system.In addition to smartphone and web apps, the keypad provides users with an alternative interface for their alarm system.The keypad allows the user to arm and disarm their system, view system status and receive visual and audio feedback regarding system status and events.Designed for convenience, the keypad can be mounted on the wall or left on a tabletop.Additionally, a rechargeable battery and AC power option provide users with the flexibility to use the keypad in ways which work best for each individual.This keypad gives users a home arming station without having to worry about wiring, picking the right location, complicated hardware installation or making modifications to their homes.The keypad will include an interactive button interface, an informational display, a speaker, various LED lights, wall mount option, battery power, AC power option and additional features to extend control of the Ring Protect system beyond the users mobile device and web applications.The keypad is intended to be used as a dumb terminal and will be non-programmable for end users.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 1| 1. Notification Report.Keypad will send Notification Report to the
associated nodes when AC power or/and PIR sensor is triggered.2. Entry Control
Notification.Keypad will send Entry Control Notification to the associated
nodes when the mode button is triggered.3. Battery Report.Keypad will send
Battery Report when the battery level is low and the battery reports value is
0xFF.4. Device Reset Locally Notification.
---|---|---
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Battery Report Interval
Battery Report Interval: Default Heartbeat check in time.Available settings:
70-1440 mins.
Size: 2 Byte, Default Value: 70
SettingDescription
70 – 1440 | minutes |
---|
Parameter 10: Key Tone Volume
Key Tone Volume: Volume, Tone Time, FrequencyAvailable settings: 0-10
Size: 1 Byte, Default Value: 8
SettingDescription
0 – 10 | level |
---|
Parameter 11: Ambient Light Sensor Level
Ambient Light Sensor Level: Light threshold where keypad will stop
backlighting if higher thanAvailable settings: 0-100
Size: 1 Byte, Default Value: 5
SettingDescription
0 – 100 | level |
---|
Parameter 12: Siren Volume
Siren Volume: Volume to produce loudest output, Needs to be
calibratedAvailable settings: 50-100
Size: 1 Byte, Default Value: 50
SettingDescription
50 – 100 | volume |
---|
Parameter 13: Proximity On/OFF
Proximity On/OFF: Turn On and Off the Proximity Detection.0 = off1 = on
Size: 1 Byte, Default Value: 1
SettingDescription
0 | off |
---|---|
1 | on |
Parameter 14: Proximity Distance
Proximity Distance: Adjusts the proximity distance (CM) If applicable to the
product.Available settings: 0-100CM
Size: 1 Byte, Default Value: 100
SettingDescription
0 – 100 | CM |
---|
Parameter 15: Extended Battery Life LED Brightness Adjustment
Extended Battery Life LED Brightness Adjustment: Percentage of brightness
for all LEDs in Power Mode = Extended (needs calibration)Available settings:
0-100%
Size: 1 Byte, Default Value: 50
SettingDescription
0 – 100 | percentage |
---|
Parameter 16: Reduced Battery Life LED Brightness Adjustment
Reduced Battery Life LED Brightness Adjustment: Percentage of brightness for
all LEDs in Power Mode = Reduced (needs calibration)Available settings:
0-100%
Size: 1 Byte, Default Value: 65
SettingDescription
0 – 100 | percentage |
---|
Parameter 17: Fast Blink Rate
Fast Blink Rate: LSB = 0.1 sec Fast Rate Type to blink the LEDsAvailable
settings: 0-100
Size: 1 Byte, Default Value: 5
SettingDescription
0 – 100 | 0.1 sec |
---|
Parameter 18: Slow Blink Rate
Slow Blink Rate: LSB = 0.5 sec Slow Rate Type to blink the LEDsAvailable
settings: 0-100
Size: 1 Byte, Default Value: 2
SettingDescription
0 – 100 | 0.5 sec |
---|
Parameter 2: Z-Wave Sleep Timeout
Z-Wave Sleep Timeout: Time to wait after receiving ZW for more OTA
messages.Available settings: 1-3 seconds
Size: 1 Byte, Default Value: 1
SettingDescription
1 – 3 | seconds |
---|
Parameter 3: Co-Proc Is Alive
Co-Proc Is Alive: Base Station check to see if the co-proc is operational.0
= No1 = Yes
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1 | Life status |
---|
Parameter 4: Proximity Timeout
Proximity Timeout : Timeout when proximity is detected and no input is
received.Available settings:0-30 seconds
Size: 1 Byte, Default Value: 3
SettingDescription
0 – 30 | seconds |
---|
Parameter 5: Button Press Timeout
Button Press Timeout : Timeout when a button is pressed, but a sequence is
not completed and buttons are no longer being pressedAvailable settings:0-30
seconds
Size: 1 Byte, Default Value: 5
SettingDescription
0 – 30 | seconds |
---|
Parameter 6: Status Change Timeout
Status Change Timeout:Available settings:10-60 seconds
Size: 1 Byte, Default Value: 15
SettingDescription
10 – 60 | seconds |
---|
Parameter 7: Power Mode
Power Mode: Set the battery power saving mode for the keypad.0=Extended
Battery Life1=Normal Battery Life
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Extended Battery Life |
---|---|
1 | Normal Battery Life |
70 – 1440 | mins |
Parameter 8: Key Backlight Timeout
Key Backlight Timeout: Timeout for keypad LED backlight to stay on between
key presses.Available settings:1-15 seconds
Size: 1 Byte, Default Value: 3
SettingDescription
1 – 15 | seconds |
---|
Parameter 9: Key Backlight Brightness
Key Backlight Brightness: Adjusts the brightness of the keypad
backlightAvailable settings: 0-100%
Size: 1 Byte, Default Value: 25
SettingDescription
0 – 100 | percentage |
---|
Technical Data
Hardware Platform | ZM5101 |
---|---|
Device Type | Entry Control Keypad |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 4 FW: 2.14:01.72:01.00:01.00:ERROR |
Z-Wave Version | 6.81.02 |
Certification ID | ZC10-19076691 |
Z-Wave Product Id | 0x0346.0x0101.0x0201 |
Supported Notification Types | Home SecurityPower Management |
Color | White |
Security V2 | S2_ACCESS_CONTROL |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Supported Command Classes
- Association Grp Info
- Association V2
- Battery
- Configuration
- Device Reset Locally
- Entry Control
- Indicator
- Manufacturer Specific V2
- Notification V8
- Powerlevel
- Security
- Security 2
- Supervision
- Transport Service V2
- Version V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>