Philio Technology (Door sensor) PST02-5C Manual (Door sensor)

October 28, 2023
Philio Technology

Philio Technology

(Door sensor)

SKU: PST02-5C

Quickstart

This is a
secure
Alarm Sensor
for
Russia
.

Please make sure the internal battery is fully charged.

To add this device to your network execute the following action:
1. Have Z-WaveTM Controller enter inclusion mode.2. Pressing tamper key three times within 1.5 secondswill enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller, about 20 seconds

Please refer to the
Manufacturers Manual
for more information.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

The slim multisensor PST02-1C has door/window, temperature and illumination, 3 sensors function in one,based on Z-Wave technologyIt is the Z-WaveTM plus product, it support the security, OTA… Thosenewest features of the Z-WaveTM technology. Z-WaveTM is a wirelesscommunication protocol designed for home automation, specifically toremotely control applications in residential and light commercialenvironments. The technology uses a low-power RF radio embedded orretrofitted into home electronics devices and systems, such as lighting,home access control, entertainment systems and household appliances.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

Notice: Use this procedure only in the eventthat the primary controller is lost or otherwise inoperable.1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key on the 4th press, the LED lite will ON.2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second.Otherwise, the LED will flash once.3. IDs are excluded and all settings will reset to factory default.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

1. Have Z-WaveTM Controller enter inclusion mode.2. Pressing tamper key three times within 1.5 secondswill enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller, about 20 seconds

Exclusion

1. Have Z-WaveTM Controller enter exclusion mode.2. Pressing tamper key three times within 1.5 seconds will enter the exclusion mode.Node ID has been excluded.

Communication to a Sleeping device (Wakeup)

This device is battery operated and turned into deep sleep state most of the time
to save battery life time. Communication with the device is limited. In order to
communicate with the device, a static controller C is needed in the network.
This controller will maintain a mailbox for the battery operated devices and store
commands that can not be received during deep sleep state. Without such a controller,
communication may become impossible and/or the battery life time is significantly
decreased.

This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the desired
wakeup interval and the node ID of the controller. If the device was included by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please perform
the following action:

After the device adding to the network, it will wake-up once per day indefault. When it wakes-up it will broadcast the Wake Up Notificationmessage to the network, and wake-up 10 seconds to receive thesetting commands.The wake-up interval minimum setting is 30 minutes, and maximumsetting is 120 hours. And the interval step is 30 minutes.If the user want to wake-up the device immediately, please remove thefront cover, and press the tamper key once. The device will wake-up 10seconds.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1| 8| The group 1 is forreceiving the report message, like triggered event,temperature, illumination etc.
---|---|---
2| 8| The group 2 is for lightcontrol, the device will send the Basic Set commandto this group.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 10: Auto Report Battery Time

The interval time for auto report thebattery level.0 means turn off auto report battery.The default value is 12. The tick timecan setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

SettingDescription

0 – 127| The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20.
---|---

Parameter 11: Auto Report Door/Windo w State Time

The interval time for auto report thedoor/window state.0 means turn off auto reportdoor/window state.The default value is 12. The tick timecan setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

SettingDescription

0 – 127| The interval time for auto report the door/window state. 0 means turn off auto report door/window state. The default value is 12. The tick time can setting by the configuration No.20.
---|---

Parameter 12: Auto Report Illumination Time

The interval time for auto report theillumination.0 means turn off auto reportillumination.The default value is 12. The tick timecan setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

SettingDescription

0 – 127| The interval time for auto report the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20.
---|---

Parameter 13: Auto Report Temperatur e Time

The interval time for auto report thetemperature.0 means turn off auto reporttemperature.The default value is 12. The tick timecan setting by the configuration No.20.
Size: 1 Byte, Default Value: 12

SettingDescription

0 – 127| The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can setting by the configuration No.20.
---|---

Parameter 2: Basic Set Level

Setting the BASIC command value toturn on the light. The 0xFF(-1) meansturn on the light. For dimmerequipment 1 to 100 means the lightstrength.0 means turn off the light.Caution: The value is unsigned byte,the range is from 0x00 ~ 0xFF.
Size: 1 Byte, Default Value: -127

SettingDescription

-127 – 127 Setting the BASIC command value to turn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF.

Parameter 20: Auto Report Tick Interval

The interval time for auto report eachtick. Setting this configuration willeffect configuration No.10, No.11,No.12 and No.13.The unit is 1 minute.Caution1: Setting to 0 means turnoff all auto report function.Caution2: The value is unsignedbyte, the range is from 0x00 ~ 0xFF
Size: 1 Byte, Default Value: 30

SettingDescription

-127 – 127 The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. The unit is 1 minute. Caution1: Setting to 0 means turn off all auto report function. Caution2: The value is unsigned byte, the range is from 0x00 ~ 0xFF

Parameter 21: Temperature Differential Report

The temperature differential to report.0 means turn off this function.The unit is Fahrenheit.Enable this function the device willdetect every minutes.And when the temperature is over 140degree Fahrenheit, it will continuereport.Enable this functionality will causesome issue please see the detail in theTemperature Report section.
Size: 1 Byte, Default Value: 1

SettingDescription

0 – 127| The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the Temperature Report section.
---|---

Parameter 22: Illumination Differential Report

The illumination differential to report.0 means turn off this function.The unit is percentage.Enable this function the device willdetect every minutes.Enable this functionality will causesome issue please see the detail in theIllumination Report section.
Size: 1 Byte, Default Value: 0

SettingDescription

0 – 99| The illumination differential to report. 0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the Illumination Report section.
---|---

Parameter 4: Light Threshold

Setting the illumination threshold toturn on the light. When the eventtriggered and the environmentillumination lower then the threshold,the device will turn on the light.0 means turn off illumination detectedfunction. And never turn on the light.1 means darkest.99 means brightest.100 means turn off illuminationdetected function. And always turn onthe light.Notice: In none test mode, only thevalue in 1 to 99 will enable theillumination detected function andupdate the illumination value.
Size: 1 Byte, Default Value: 99

SettingDescription

0 – 100| Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn on the light. 0 means turn off illumination detected function. And never turn on the light. 1 means darkest. 99 means brightest. 100 means turn off illumination detected function. And always turn on the light. Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value.
---|---

Parameter 5: Operation Mode

Operation mode. Using bit to control.Caution: The value is unsigned byte,the range is from 0x00 ~ 0xFF.Bit1: 1 means test mode,0 means normal mode.Notice:This bit only effect by the DIP Switchsetting to customer mode, otherwiseit decides by DIP Switch setting toTest or Normal Mode.Bit2: Disable the door/windowfunction. (1:Disable, 0:Enable)Bit3: Setting the temperature scale.0: Fahrenheit, 1:CelsiusBit4: Disable the illumination reportafter event triggered. (1:Disable,0:Enable)Bit5: Disable the temperature reportafter event triggered. (1:Disable,0:Enable)
Size: 1 Byte, Default Value: 0

SettingDescription

1| Bit1: 1 means test mode, 0 means normal mode. Notice: This bit only effect by the DIP Switch setting to customer mode, otherwise it decides by DIP Switch setting to Test or Normal Mode.
---|---
2| Disable the door/window function. (1:Disable, 0:Enable)
3| Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius
4| Bit4: Disable the illumination report after event triggered. (1:Disable, 0:Enable)
5| Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable)

Parameter 6: Mult- Sensor Function Switch

Multisensor function switch. Using bitto control.Caution: The value is unsigned byte,the range is from 0x00 ~ 0xFF.Bit0: Disable magnetic integrateillumination to turn ON the lightingnodes in the association group 2.(1:Disable, 0:Enable)Bit4: Disable delay 5 seconds to turnoff the light, when door/windowBit5: Disable auto turn off the light,after door/window opened to turn onthe light. (1:Disable, 0:Enable)Notice: If bit2 is zero, this setting isuseless.Notice: If the configuration No.9 iszero, this setting is useless.
Size: 1 Byte, Default Value: 4

SettingDescription

0| Bit0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable)
---|---
4| Bit4: Disable delay 5 seconds to turn off the light, when door/window
5| Bit5: Disable auto turn off the light, after door/window opened to turn on the light. (1:Disable, 0:Enable) Notice: If bit2 is zero, this setting is useless. Notice: If the configuration No.9 is zero, this setting is useless.

Parameter 7: Customer Function

Customer function switch, using bitcontrol.Caution: The value is unsigned byte,the range is from 0x00 ~ 0xFFBit3: Disable send out BASIC OFFafter door closed. (1:Disable,0:Enable)Bit4: Notification Type,0: Using Notification Report.1: Using Sensor Binary ReportBit5: Disable Multi CC in auto report.(1:Disable, 0:Enable)Bit6: Disable to report battery statewhen the device triggered. (1:Disable,0:Enable)
Size: 1 Byte, Default Value: 4

SettingDescription

3 Bit3: Disable send out BASIC OFF after door closed. (1:Disable, 0:Enable)
4 Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor

Binary Report
5| Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable)
6| Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable)

Parameter 9: Turn Off Light Time

After turn on the lighting, setting thedelay time to turn off the lightingwhen the PIR motion is not detected.8 seconds per tick, default tick is 4 (32seconds).0 means never send turn off lightcommand
Size: 1 Byte, Default Value: 4

SettingDescription

0 – 127| After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command
---|---

Technical Data

Hardware Platform SD3502
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.29:01.20
Z-Wave Version 6.51.02
Certification ID ZC10-18036036
Z-Wave Product Id 0x013C.0x0002.0x000E
Sensors Air TemperatureLuminance
Supported Notification Types Home Security
Frequency Russia – 868.4MHz, 869.85MHz
Maximum transmission power 5 mW

Supported Command Classes

  • Association Grp Info
  • Association V2
  • Battery
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V2
  • Manufacturer Specific V2
  • Multi Cmd
  • Notification V4
  • Powerlevel
  • Security
  • Sensor Binary V2
  • Sensor Multilevel V5
  • Version V2
  • Wake Up V2
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic
  • Configuration

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Philio Technology User Manuals

Related Manuals