- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Positioning Calibration
- Parameter 10: Set the power changed percentage to send the power report
- Parameter 11: Set the time interval of reporting watts in seconds
- Parameter 12: Set the time interval of reporting KWH in seconds
- Parameter 2: External switch Protection
- Parameter 3: When the door is opened, set the delay time for automatic
- Parameter 4: When the door is open, set the delay time for automatic
- Parameter 5: Set the operation mode
- Parameter 6: Set the angle of blinds
- Parameter 7: Set the slats turning time
- Parameter 8: Set the delay time to start the motor up to the blade
- Parameter 9: Set the delay time to start the motor down to the blade
- Technical Data
- Supported Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Good Way Technology, Co., Ltd
Roller Shutter Multi Level Switch
SKU: Roller Shutter/TD11010
Quickstart
This is a
secure
Window Covering – Pos/End Aware
for
CEPT (Europe).
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
1.Put the Z-Wave Controller into inclusion mode, and press the pairing button
3 times in 2 seconds to include the module.2.Put the Z-Wave Controller into
inclusion mode, and press the external swtich1 or external swtich2 3 times in
2 seconds to include the module.
Please refer to the
Manufacturers
Manual
for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Z-Wave Roller Shutter Controller is an ideal for the remotely electric motor controller. It is used to control the motors of rollers, shades, blinds, venetian blinds and similar sun shade, which are single phase AC powered. The module can be controlled either through a Z-Wave network or through the wall switch, and measures power consumption of motor.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
1.Press the pairing button 3 times in 2 seconds and press and hold the pairing button for more than 5 seconds at the 3rd time.2.The module is excluded and restores to factory default setting.3.Then the module will be in auto- inclusion mode for 2 minutes.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
1.Put the Z-Wave Controller into inclusion mode, and press the pairing button 3 times in 2 seconds to include the module.2.Put the Z-Wave Controller into inclusion mode, and press the external swtich1 or external swtich2 3 times in 2 seconds to include the module.
Exclusion
1.Put the Z-Wave Controller into exclusion mode, and press the pairing button 3 times in 2 seconds to exclude the device.2.Put the Z-Wave Controller into inclusion mode, and press the external swtich1 or external swtich2 3 times in 2 seconds to include the module.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 1 | Z-Wave Plus Lifeline |
---|
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Positioning Calibration
Positioning Calibration:0: Disable1: Executing calibration
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1 | Positioning Calibration |
---|
Parameter 10: Set the power changed percentage to send the power report
Set the power changed percentage to send the power report.0: Disabled1 –
100: 1% – 100%
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 100 | changed range |
---|
Parameter 11: Set the time interval of reporting watts in seconds
Set the time interval of reporting watts in seconds.0: Disable60 – 32767: 60
– 32767sec
Size: 2 Byte, Default Value: 300
SettingDescription
0 | disable |
---|---|
60 – 32767 | times |
Parameter 12: Set the time interval of reporting KWH in seconds
Set the time interval of reporting KWH in seconds.0: Disable60 – 32767: 60 –
32767sec
Size: 1 Byte, Default Value: 3600
SettingDescription
0 | disable |
---|---|
60 – 32767 | times |
Parameter 2: External switch Protection
External switch Protection:0: Enable external switch1: Disable external
switch
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1 | External switch Protection |
---|
Parameter 3: When the door is opened, set the delay time for automatic
closing.
When the door is opened, set the delay time for automatic closing.0: Disable
automatic closing1 – 32767: The door will be closed automatically in 1 –
32767sec
Size: 2 Byte, Default Value: 0
SettingDescription
0 – 32767 | delay time |
---|
Parameter 4: When the door is open, set the delay time for automatic
notification
When the door is open, set the delay time for automatic notification0:
Disable automatic notification1 – 32767: The notification will be sent
automatically in 1 – 32767sec
Size: 2 Byte, Default Value: 0
SettingDescription
0 – 32767 | delay time |
---|
Parameter 5: Set the operation mode
Set the operation mode:0: Roller Shutter1: Venetian (up/down and slate
rotation)
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 1 | Set the operation mode |
---|
Parameter 6: Set the angle of blinds
Angles of blinds00130260390412051506180
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 6 | Set the angle of blinds |
---|
Parameter 7: Set the slats turning time
Set the slats turning time:1 – 127: 0.1 – 12.7 sec
Size: 1 Byte, Default Value: 15
SettingDescription
1 – 127 | Set the slats turning time |
---|
Parameter 8: Set the delay time to start the motor up to the blade
Set the delay time to start the motor up to the blade:0: No offset time1 –
127: 0.1 – 12.7 sec
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 127 | delay time |
---|
Parameter 9: Set the delay time to start the motor down to the blade
Set the delay time to start the motor down to the blade.0: No offset time1 –
127: 0.112.7 sec
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 127 | delay time |
---|
Technical Data
Hardware Platform | ZM5101 |
---|---|
Device Type | Window Covering – Pos/End Aware |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 2.00 |
Z-Wave Version | 6.81.00 |
Certification ID | ZC10-18036063 |
Z-Wave Product Id | 0x0068.0x0003.0x0014 |
Supported Meter Type | Electric Energy |
Firmware Updatable | Updatable by Manufacturer |
Window Covering Control Features | Supports CurtainsSupports Rotation |
MotionSupports Up/Down MotionSupports Vertical Blinds
Security V2| S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency| XXfrequency
Maximum transmission power| XXantenna
Supported Command Classes
- Association Grp Info
- Association V2
- Basic
- Configuration
- Device Reset Locally
- Firmware Update Md V4
- Manufacturer Specific V2
- Meter V3
- Powerlevel
- Security
- Security 2
- Supervision
- Switch Binary
- Switch Multilevel V3
- Transport Service V2
- Version V2
- Zwaveplus Info V2
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>