Zooz 4-in-1 Sensor ZSE40 Manual
- June 8, 2024
- ZOOZ
Table of Contents
- Zooz
- 4-in-1 Sensor
- SKU: ZSE40
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Inclusion/Exclusion
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Association – one device controls an other device
- Technical Data
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Zooz
4-in-1 Sensor
SKU: ZSE40
Quickstart
This is a ****
Alarm Sensor
for
U.S. / Canada / Mexico.
To run this device please connect it to your mains power supply.
To add this device to your network execute the following action:
To add the ZSE40 to the Z-Wave network (inclusion), place the Z-Wave primary
controller into inclusion mode.Press the Program Switch of ZSE40 for sending
the NIF. After sending NIF, Z-Wave will send the auto inclusion, otherwise,
ZSE40 will go to sleep after 20 seconds.
Please refer to the
Manufacturers
Manual for more information.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
Enjoy 4 smart sensors in 1 compact device. Monitor motion, temperature, humidity, and light level.This is a secure device using 128-bit signal encryption. It requires a security enabled gateway controller for full functionality.The Zooz 4-in-1 sensor is packed with advanced features:- 7 levels of motion sensitivity to choose from- 3 modes for motion / temp led indicator notifications- Built-in tamper protection- Low battery alerts- Z-Wave Plus with improved 500 series chip for faster and safer wireless communicationZ-Wave Frequency: 908.42 MHz (US)Power: 2 AAA batteriesWireless Range: Up to 100 feet line of sightOperating Temperature: 5 – 104FInstallation: Indoor Use Only1 Year Warranty
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Remove cover to trigged tamper switch, LED flash once & send out Alarm Report.Press Program Switch 10 times within 10 seconds, ZSE40 will send the Device Reset Locally Notification command and reset to the factory default. (Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.)
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
To add the ZSE40 to the Z-Wave network (inclusion), place the Z-Wave primary controller into inclusion mode.Press the Program Switch of ZSE40 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion, otherwise, ZSE40 will go to sleep after 20 seconds.
Exclusion
To remove theZSE40 from the Z-Wave network (exclusion), place the Z-Wave primary controller into exclusion mode and follow its instruction to delete the ZSE40 to the controller.Press the Program Switch of ZSE40 once to be excluded.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
Use Wake Up command to set up the awaking time (from 10 minutes to 1 week) and send the wake up notification to controller
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 5|
LifelineCOMMAND_CLASS_BASIC_SETCOMMAND_CLASS_BATTERY_REPORTCOMMAND_CLASS_DEVICE_RESET_LOCALLY_NOTIFICATIONCOMMAND_CLASS_NOTIFICATION_REPORTCOMMAND_CLASS_SENSOR_MULTILEVEL_V7
---|---|---
Technical Data
Hardware Platform | ZM5202 |
---|---|
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 5.01:10.01 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-16055079 |
Z-Wave Product Id | 0x027A.0x2021.0x2101 |
Sensors | Air TemperatureHumidityLuminanceMotion/No Motion (Binary) |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>