Widom Energy Driven Switch Version C WIDEWPSC Manual
- June 8, 2024
- wiDom
Table of Contents
- Widom
- Energy Driven Switch Version C
- SKU: WIDEWPSC
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Device Status
- Parameter 20: Device status upon receipt of a Basic Set command
- Parameter 30: Overcurrent level
- Parameter 31: Overcurrent time
- Parameter 32: Next State
- Parameter 33: Meter Reset
- Parameter 34: Energy flow
- Parameter 35: UP Power Level
- Parameter 36: UP Power Time
- Parameter 38: UP Power Associated
- Parameter 39: DOWN Power Level
- Parameter 40: DOWN Power Time
- Parameter 41: DOWN Power State
- Parameter 42: DOWN Power Associated
- Parameter 43: Energy Level
- Parameter 44: Energy Limit State
- Parameter 45: Variation Instantaneous Power
- Parameter 46: Report Time Frequency
- Parameter 48: Nominal Voltage
- Parameter 49: Fall in maximum voltage
- Parameter 50: Electric parameters subjected to automatic notification
- Parameter 60: Start-up status
- Parameter 61: Configuration reset
- Parameter 62: Type of external switch
- Parameter 63: Load control
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Widom
Energy Driven Switch Version C
SKU: WIDEWPSC
Quickstart
This is a ****
On/Off Power Switch
for
Europe.
To run this device please connect it to your mains power supply.
1. Put your system controller into inclusion mode by following the
instructions provided by your controller manufacturer.
2. Press the push button (B) located on the top of the device once.”
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The smallest device in its category worldwide, and the only device
specifically intended for use both as a Relay Switch with integrated power
meter, and as an Energy Meter either at the point of entry of your electrical
system, or on a section of the latter. Available in two versions, version S
featuring an internal shunt resistor, and version C featuring an external
current transformer, it is capable of measuring loads exceeding 10 KW. In
addition to Power measurements, the device also provides data for Energy,
Voltage, Current and Power factor.
The only device suited for use with all types of Z-Wave controller, and
capable of implementing an active energy-saving management policy defined by
the user according to his energy consumption, or to the amount of energy
produced by his solar power system. It automatically connects and disconnects
a specific load if the threshold limit is exceeded, or “supplies—
the required power, momentarily excluding non-priority loads.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
Press the push button (B) located on the top of the device six consecutive times within one minute from system start-up.
Safety Warning for Mains Powered Devices
ATTENTION: only authorized technicians under consideration of the country-
specific
installation guidelines/norms may do works with mains power. Prior to the
assembly of
the product, the voltage network has to be switched off and ensured against
re-switching.
Installation
WiDom Driven Switch Activation
- Ensure that the main power switch is set in the OFF position”
- Connect the device following the diagrams provided”
- Shut the electrical box containing the device”
- Turn the main power switch back on”
- Include the device into the Z-Wave network
Electrical Connections”
The device must be supplied by phase and neutral. Connections must be made according to one of the diagrams below.
Local load contro l”
In this mode the load is controlled directly by the internal relay. The opening and closing of the relay contacts are synchronized to take place, respectively, when a zero current or voltage is reached.
Remote load control ”
In this mode the device has no locally connected load, and the measures of
current and power are based on all devices connected to the “LINE OUTâ€
section of the system. The devices connected to the “LINE OUT†can be
controlled individually based on the configured energy events.
Load control by external contactor
This mode, available only for version C and the use of an external contactor, allows the management of loads
up to 45A. The device supports two types of external contactors:
– Normally open (in the absence of signal from the relay the “LINE OUT†is disconnected)
– Normally close (in the absence of signal from the relay the “LINE OUT†is connected)
The load control mode and type of external contactor can be set up with parameter No. 63.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
Press the once ” push button (B) located on the top of the device or push once the external Switch.
Exclusion
Press the three times the push button (B)
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 8| Z-Wave Plus Lifeline:Devices to receive notifications on: status
changes; energy and power levels; device local reset
---|---|---
2| 8| Up Power Level Group:Devices controlled by the Up Power event
3| 8| Down Power Level Group:Devices controlled by the Down Power event
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Device Status
Controlling the relay by means of a single click on the external switch or
on the integrated button.
Size: 1 Byte, Default Value: 1
SettingDescription
1 | TOGGLE |
---|---|
2 | ON |
3 | OFF |
4 | IGNORE |
Parameter 20: Device status upon receipt of a Basic Set command
The final status achieved by the device when it receives a Basic Set command
through the Z-Wave network.
Size: 1 Byte, Default Value: 0
SettingDescription
1 | AS RECEIVED |
---|---|
2 | IGNORE IF ON |
3 | IGNORE IF OFF |
4 | IGNORE |
Parameter 30: Overcurrent level
Sets the current level above which the time spent above that level is
measured.
Size: 2 Byte, Default Value: 1250
SettingDescription
0 – 1250 | Overcurren level in hundredths of Amperes |
---|
Parameter 31: Overcurrent time
Sets the time beyond which, in the case of overcurrent at a level higher
than that established in parameter 30, an OverCurrent event occurs.
Size: 2 Byte, Default Value: 10
SettingDescription
0 – 10800 | Time in seconds |
---|
Parameter 32: Next State
Defines the next state of the device if an overcurrent event has occurred.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | IGNORE |
---|---|
1 | ON |
2 | OFF |
3 | TOGGLE |
Parameter 33: Meter Reset
Provides total operating time from last meter reset. When set to 0 it resets
the cumulated values of energy and total operating time.
Size: 4 Byte, Default Value: 1
SettingDescription
0 | RESET METER |
---|
Parameter 34: Energy flow
Determines whether energy events are related to energy consumed or energy
produced.
Size: 1 Byte, Default Value: 1
SettingDescription
1 | Consumed |
---|---|
2 | Produced |
Parameter 35: UP Power Level
Sets the level of instantaneous power in Watts beyond which time of
permanence above this level is calculated.
Size: 2 Byte, Default Value: 3000
SettingDescription
0 – 3000 | UP Power level in Watt |
---|
Parameter 36: UP Power Time
Sets the time in seconds beyond which, if instantaneous power remains at
levels exceeding threshold defined by parameter 35, a UP Power event occurs.
Size: 2 Byte, Default Value: 0
SettingDescription
0 – 10800 | UP Power Time in seconds |
---|
Parameter 38: UP Power Associated
Defines the status of associated devices in the presence of a UP Power
event.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | OFF |
---|---|
1 – 99 | Dimming |
100 | ON |
Parameter 39: DOWN Power Level
Sets the level of instantaneous power beyond which the time of permanence
below this level is calculated.
Size: 2 Byte, Default Value: 0
SettingDescription
0 – 11250 | DOWN Power Level in Watt |
---|
Parameter 40: DOWN Power Time
Sets the time beyond which, if instantaneous power remains at levels below
threshold defined by parameter 39, a DOWN Power event occurs.
Size: 2 Byte, Default Value: 10
SettingDescription
0 – 10800 | DOWN Power Time in seconds |
---|
Parameter 41: DOWN Power State
Defines the next state of the device in the case of a DOWN Power event
occurring.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | IGNORE |
---|---|
1 | ON |
2 | OFF |
3 | TOGGLE |
Parameter 42: DOWN Power Associated
Defines the status of associated devices in the presence of a DOWN Power
event.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | OFF |
---|---|
1 – 99 | Dimming |
255 | ON |
Parameter 43: Energy Level
Sets the energy level that once exceeded an Energy Limit event occurs.
Size: 4 Byte, Default Value: 2000000
SettingDescription
0 – 2000000 | Energy Level in KWh |
---|
Parameter 44: Energy Limit State
Defines the next state of the device in the case of an Energy Limit event
occurring.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | IGNORE |
---|---|
1 | ON |
2 | OFF |
3 | TOGGLE |
Parameter 45: Variation Instantaneous Power
Defines the percentage variation of instantaneous power determining the
sending of the report.
Size: 1 Byte, Default Value: 10
SettingDescription
1 – 100 | Power variation in percentage |
---|
Parameter 46: Report Time Frequency
Defines the maximum time in minutes since the previous report beyond which
an Instantaneous Power Report will still be sent.
Size: 1 Byte, Default Value: 10
SettingDescription
1 – 100 | Time in minutes |
---|
Parameter 48: Nominal Voltage
Defines the nominal voltage value in tenths of volts. Together with
parameter No. 49 this is used by the automatic notification system to send
reports on variations of voltage.
Size: 2 Byte, Default Value: 2300
SettingDescription
1100 – 2300 | Nominal Voltage in Volt |
---|
Parameter 49: Fall in maximum voltage
Defines, as a percentage, the nominal value for permitted fall in maximum
voltage.
Size: 1 Byte, Default Value: 10
SettingDescription
1 – 100 | percentage of voltage variation |
---|
Parameter 50: Electric parameters subjected to automatic notification
Defines which electric parameters, other than power, will be subjected to
automatic notification.The value to be set for this parameter must be
calculated as the sum of values associated to the individual electric
parameter.
Size: 1 Byte, Default Value: 30
SettingDescription
0 | Power |
---|---|
2 | Energy |
4 | Voltage |
8 | Current |
16 | Power Factor |
32 | Multilevel Sensor: Power Report |
Parameter 60: Start-up status
Defines the status of the device following a restart.
Size: 1 Byte, Default Value: 3
SettingDescription
1 | ON |
---|---|
2 | OFF |
3 | Status prior to restart |
Parameter 61: Configuration reset
Defines which parameters should be reset to default values.
Size: 1 Byte, Default Value: 4
SettingDescription
0 | FACTORY RESET |
---|---|
1 | ASSOCIATIONS RESET |
2 | CONFIGURATIONS RESET |
4 | IGNORE |
Parameter 62: Type of external switch
Defines the type of external switch connected to the device.
Size: 1 Byte, Default Value: 4
SettingDescription
0 | IGNORE |
---|---|
1 | BUTTON |
2 | SWITCH |
4 | AUTOMATIC RECOGNITION |
Parameter 63: Load control
Defines the load control mode.
Size: 1 Byte, Default Value: 1
SettingDescription
1 | DIRECT CONTROL |
---|---|
2 | CONTROL BY MEANS OF A CONTACTOR WITH NORMALLY OPEN COMMAND |
3 | CONTROL BY MEANS OF A CONTACTOR WITH NORMALLY CLOSED COMMAND |
4 | AS AN EXTERNAL INDICATOR |
Technical Data
Dimensions | 0.0370000×0.0370000×0.0170000 mm |
---|---|
Weight | 70 gr |
Hardware Platform | ZM5202 |
EAN | 8059265060023 |
IP Class | IP 20 |
Voltage | 230V |
Load | 12,5A |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Z-Wave Version | 6.51.03 |
Certification ID | ZC10-15030011 |
Z-Wave Product Id | 0x0149.0x1214.0x0304 |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Switch All
- Association
- Association Group Information
- Basic
- Configuration
- Device Reset Locally
- Firmware Update Md
- Manufacturer Specific
- Meter
- Sensor Multilevel
- Powerlevel
- Switch Binary
- Version
- Zwaveplus Info
Controlled Command Classes
- Basic
- Device Reset Locally
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.