WiDom WDSL700 Smart Double Switch Instruction Manual

June 12, 2024
wiDom

WiDom logo


Smart Double Switch L 7


WDSL700 Operating Instructions

Revision History
Rev. Doc. Date Author Reviser Page Description
0 25/03/22 GG IR-GT All Initial Version
Device Description

Smart Double Switch L 7 is an ON/OFF control device designed to independently control two separate loads , suited for being controlled by both remote and local switches. Similarly to the other Smart Serie 7 devices, it can be fully integrated into pre-existing systems and configured to associate configurable behaviors to a specific number of clicks, in full integration with the Z-Wave™ home automation ecosystem.

There are two versions of Smart Double Switch L 7:

L version – controlled by Line signal;

N version – controlled by Neutral signal.

Each of its two channels features an integrated consumption measurement device. Smart Double Switch L 7 also boasts the lowest energy consumption on the market.

It is very easy to install and works with both momentary and toggle switch. At the same time, it is completely configurable so that it can adapt to the most varied needs while also being ready to be used without needing additional configurations in order to operate.

The device is equipped with contact protection technology (Zero Crossing) which reduces the electrical stress on the relay contacts and ensures a longer life. The open / closed switching of the device always occur when the instantaneous value of voltage is 0.

It operates in any Z-Wave™ network with other Z-Wave™/Z-Wave Plus™ certified devices and controllers from any other manufacturer. As a constantly powered node, the device will act as repeater regardless of the vendor in order to increase the reliability of the network.

This device is a security enabled Z-Wave Plus™ product that is able to use encrypted Z-Wave Plus™ messages to communicate to other security enabled Z-Wave Plus™ products.

This device must be used in conjunction with a Security Enabled Z-Wave™ Controller in order to fully utilize all implemented functions

  1. Integrated Button

Integrated Button| 1 or 3 clicks to enter in Learn Mode
6 clicks to reset the system to manufacturer’s settings
2 clicks to enter in setup mode
---|---
Power Supply| 1 – Null
6 – Line
Input Switch| 2 – Input 2 Line signal/Null signal in version L/N
3 – Input 1 Line signal/Null signal in version L/N
Output| 4 – Output 2 Line referred to Null
5 – Output 1 Line referred to Null

Technical Specifications

Power Supply| 110 – 230 VAC±10% 50/60 Hz

24 VDC
---|---
Maximum Load on Relay| Resistive Loads: 8 A for each channel; 10A for both channels
System temperature limitation| 105 °C
Work Temperature| From -10° to 40° C
Power consumption| < 260 mW in standby
< 480 mW with one working load
< 700 mW with both working loads
Radio frequency| 868.4 MHz
Protection system| S2 Security
Maximum distance| Up to 100 m outdoor
Up to 40 m indoor
Dimensions| 37x37x17 mm
Actuator element| Relay
Conformity| CE, RoHS
Electrical IP Rating| IP 20

Safety information

INFO: The device is designed to be installed in flush mounting junction boxes, close to the loads to be controlled.

WARNING: The device must be installed by electricians qualified to operate on electrical systems in compliance with safety requirements set out by current regulations.

DANGER: The device must be connected to 230V AC, before carrying out any operation, please make sure that the power main switch is in OFF position.

DANGER: Any procedure requiring the use of the Integrated Button is related only to the installation phase and is to be considered a service procedure that must be performed by qualified personnel. This operation must be performed with all necessary precautions for operating in areas with a single level of insulation.

WARNING: Do not connect loads exceeding the maximum power load permitted by the relay contacts.

WARNING: All connections must be performed according to the electrical diagrams provided.

WARNING: The device must be installed in norm-compliant systems suitably protected from overloads and short circuits.

Electrical Connections diagram

The device must be supplied by phase and neutral.

There are two versions of Smart Double Switch L 7 available, in order that you can choose the most suitable for your electrical system:

  • Version N: used in systems that require to be controlled by Neutral signal
  • Version L: used in systems that require to be controlled by Line signal
  • Both version N and version L can be connected in a VDC system

Connections must be made according to one of the diagrams below.

Version L

| Version N

WiDom WDSL700 - Electrical Connections 2

| Version N

WiDom WDSL700 - Electrical Connections 3

---|---|---
Power Supply: 1 – Neutral, 6 – Line;
Output Loads: 5 – O1, 4 – O2;
Input switches: 3 – I1, 2 – I2| Power Supply: 1 – 24VDC+ , 6 – VDC- ;
Output Loads: 5 – O1, 4 – O2;
Input witches: Non supported

WARNING: The line must be properly protected from overloads and short circuits related to a possible failure of the loads connected to the output O1 and O2

Device Installation
  1. Make sure the main switch is set to the OFF position

  2. Connect the device based on the diagrams provided

  3. Turn the main switch to the ON position

  4. Include the device into the Z-Wave™ network

TIP: The antenna must not be shortened, removed or modified. To ensure maximum efficiency, it must be installed as shown. Large size metal equipment near the antenna can negatively affect reception. Each device is a node in a mesh network. If there are metal obstacles, the obstacle can often be overcome with a further triangulation node.

LED status indicator

The system includes an RGB LED that shows the device’s status during installation:

Solid RED: the device is not included in any network

Solid BLUE: the device is Offline setup mode

4 GREEN blinks then OFF: the device has been just added to a Z-Wave™ network in S2 Authenticate Mode

4 BLUE blinks then OFF: the device has been just added to a Z-Wave™ network in S2 Unauthenticated Mode

4 RED blinks then OFF: the device has been just added to a Z-Wave™ network without security

Sequence of GREEN–BLUE Learn Mode for inclusion

Sequence of RED–BLUE Learn Mode for exclusion

Rapid sequence of GREEN –BLUE–RED: the event on the input (external switch) is not valid

TIP: To test if the electrical connections are correct, before the inclusion of the device, while pressing n times the external switch, the RGB LED should flash green for the same amount of times. If it does not, check the wire connections.

Add/Remove the device into a Z-Wave™ network (classic)
Standard Inclusion (add)

All Smart Serie 7 devices are compatible with all Z-Wave™/Z-Wave Plus™ certified controllers. The devices support both the Network Wide Inclusion mechanism (which offers the ability to be included in a network, even if the device is not directly connected to the controller) and Normal Inclusion.

By default, the inclusion procedure starts in Normal Inclusion mode and after a short timeout the procedure continues in Network Wide Inclusion mode that lasts for about 20 Seconds.

Only a controller can add the device into the network. After activating the inclusion function by the controller, the device can be added by setting it in Learn Mode.

Before including the device, the LED status indicator is solid RED. The adding of a device is executed by activating the adding procedure in the inclusion section of the controller interface and executing 1 or 3 click on the integrated button (the device is set in Learn Mode ). As soon as the inclusion procedure initiates the LED indicator starts a sequence of GREEN- BLUE blinks. The device is included in the network when the LED status is OFF and the interview is completed.

Standard exclusion (remove)

Only a controller can remove the device from the network. After activating the exclusion function by the controller, the device can be removed by setting it in Learn Mode.

The procedure of exclusion can be activated by Removing a node from the Z-Wave™ network and executing 1 or 3 click on the integrated button; as soon as the exclusion initiates, the LED indicator starts a sequence of RED-BLUE blinks. The device is excluded from the network when the LED status indicator is solid RED and the App_status in the interface is OK.

SmartStart Inclusion

Z-Wave™ SmartStart aims to shift the tasks related to inclusion of an end device into a Z-Wave™ network away from the end device itself, and towards the more user-friendly interface of the gateway.

Z-Wave™ SmartStart removes the need for initiating the end device to start inclusion. Inclusion is initiated automatically on power-ON and repeated at dynamic intervals for as long as the device is not included into a Z-Wave™ network. As the new device announces itself on power-ON, the protocol will provide notifications, and the gateway can initiate the inclusion process in the background, without the need for user interaction or any interruption of normal operation. The Smart Start inclusion process only includes authenticated devices.

Smart Serie 7 devices can be added into a Z-Wave™ network by scanning the Z-Wave™ QR Code present on the product with a controller providing SmartStart inclusion. No further action is required and the SmartStart product will be added automatically within 10 minutes of being switched on in the network vicinity.

The SmartStart QR and the full DSK string code can be found on the back of the device. The PIN is the first group of 5 digits printed underlined. If you plan to use the DSK, it is important that you take a picture of the label and keep it in a safe place.

WiDom WDSL700 - SmartStart Inclusion

S2 Secure inclusion

When adding Smart Serie 7 devices to a Z-Wave™ network with a controller supporting Security 2 Authenticated (S2), the PIN code of the Z-Wave™ Device Specific Key (DSK) is required. The unique DSK code is printed on the product label. The first five digits of the key are highlighted and underlined to help the user identify the PIN code

  1. Pin Code
Supported Command Classes

Command Class|

Version

| Non-Secure CC|

Secure CC

---|---|---|---
BASIC|

2

| |

x

ZWAVEPLUS_INFO|

2

|

x

|
ASSOCIATION|

2

| |

x

MULTI_CHANNEL_ASSOCIATION_V2|

3

| |

x

ASSOCIATION_GRP_INFO|

3

| |

x

TRANSPORT_SERVICE|

2

|

x

|
VERSION|

3

| |

x

MANUFACTURER_SPECIFIC|

2

| |

x

DEVICE_RESET_LOCALLY|

1

| |

x

INDICATOR|

3

| |

x

POWERLEVEL|

1

| |

x

SECURITY_2|

1

|

x

|
SUPERVISION|

1

|

x

|
MULTI_CHANNEL_V4|

4

| |

x

FIRMWARE_UPDATE_MD|

5

| |

x

APPLICATION_STATUS|

1

|

x

|
CONFIGURATION_V4|

4

| |

x

SWITCH_BINARY|

2

| |

x

CENTRAL_SCENE|

3

| |

x

METER|

5

| |

x

Supporting Command Class Basic

The basic command classes are mapped into the Switch Binary Command Class.

Basic Command received Mapped Command (Binary Switch)
Basic Set (0xFF) Switch Binary Set (0xFF)
Basic Set (0x00) Switch Binary Set (0x00)
Basic GET Basic Report 0x00 if the Binary Switch is in Off state 0x00

Basic Report 0xFF if the Binary Switch is in On state 0xFF

Supporting Command Class Indicator

The device supports the Command Class Indicator V3 (ID 0x50). When the device receives an indicator set, the led blinks accordingly to the Indicator set received.

The color shown by the indicator will be:

RED : if the device is included without Security

BLUE : if the device is included in S2 Unauthenticated Mode

GREEN : if the device is already included in S2 Authenticate Mode

Device Control

Smart Double Switch L 7 can control two separate loads by using an external switch for each channel, or from remote through a controller.

Controlling the device by External Switches

For the operation of the device within the Z-Wave™ network and controlling the loads connected to the device, control actions are performed on the switches.

The CONTROL ACTIONS are EVENTS executed on EXTERNAL SWITCHES terminal of the device which can be Clicks, Hold Down and Up.

Event Type of switch Actions on the switch
Click Momentary switch (button) Press briefly & Release

(when pressed it autonomously returns to the initial position)
Toggle Switch (bistabile)| Press & Release
(a single click means one single flip of the switch)
MultiClick= n clicks| Momentary switch| Sequence of consecutive n clicks
Toggle Switch
Hold Down| Momentary switch| Press longer than click.
After a Hold Down always follows an UP event.
Up| Momentary switch| Release.
The event applies only if there has been a previous Hold Down event.

Since the device supports Central Scene Notification all the events described in the table will be notified with a Central Scene Notification Report to the Lifeline. The events that trigger a Central Scene Notification Report can be customized with the configuration parameter in the Central Scene Notification Parameter section.

Controlling the device by a Z-Wave™ controller

The device can be controlled by any Z-Wave™ / Z-Wave Plus™ certified controller available in the market.

Associations

Smart Double Switch L 7 can control other devices of both traditional and multi-channel type. It can also control other devices such as relays or dimmers. The device supports 7 association groups, each of which supports the association of up to 8 devices (nodes):

Lifeline group: Nodes belonging to this group will receive: notifications about device reset; changes related to the relay status and meter reports.

Groups from 2 to 7: Nodes belonging to these groups will be controlled by a basic set if the external switch receives one or more clicks.

Group ID

|

Group Name

| N° of max nodes supported in the group| Description|

Command sent

|

End Point ID

---|---|---|---|---|---

1

|

Lifeline

|

8

| LifeLine Group| DEVICE_RESET_LOCALLY_NOTIFICATION
SWITCH_BINARY_REPORT
METER_REPORT
CENTRAL_SCENE_NOTIFICATION
INDICATOR_REPORT|

0

2

| Follow ch1 state|

8

| The state of the output 1 (ON/OFF) will be propagated to the associated device| BASIC_SET|

1

3

| clicks on button 1
G1|

8

| The associated device will be controlled based on the click events and output propagation defined by configuration parameters on the Association group management section|

1

4

| clicks on button 1
G2|

8

|

1

5

| Follow ch2 state|

8

| The state of the output 2 (ON/OFF) will be propagated to the associated device|

2

6

| clicks on button 2
G1|

8

| The associated device will be controlled based on the click events and output propagation defined by configuration parameters on the Association group management section|

2

7

| clicks on button 2
G2|

8

| |

2

  INFO: Association ensures direct transfer of control commands between devices and is performed without participation of the main controller.

Special features
Timer Management

An independent timer for each channel can be set when switching On and/or Off. It also possible to define which event will start the timer. (for example only the change on the output due to double clicks).

Power consumption management

Smart Double Switch L 7 is equipped with a very precise power metering functionality, therefore you can easily monitor the instantaneous power and cumulated energy for each channel.

Offline setup Mode

The device has a unique feature that allows to configure some parameters without using any user interface. This feature enables the professional user to setup the main features of the device in the field even if the device is not included in a Z-Wave™ Network. When the device will be included in the network all these configuration parameters will be maintained.

To enter in offline setup mode, operate 2 clicks on the integrated button.

When the device is in Offline setup mode the led becomes solid Blue and the following configurations are permitted:

1 click| Setup inputs type to toggle switch. Equivalent to set parameters 1,2 to 2
---|---
2 clicks| Activate a switch Off timer of 10 minutes on channel 1. Equivalent to set parameter n.30 to 15 and parameter n.31 to 6000
3 clicks| Activate a switch Off timer of 5 minutes on channel 1. Equivalent to set parameter n.30 to 15 and parameter n.31 to 3000
After receiving the command the led blinks a number of times equal to the number of clicks recognized
6 clicks| Exit from Offline setup mode and return to normal operation
Hold down for 5 seconds| Reset all configuration parameters to their default value and return to normal operation

After entering in Offline setup mode, the device returns to normal operation if no action on the switch is detected for more than 20 Seconds.

Reset to the factory settings

The device can be reset to the original factory settings with 6 consecutive clicks on the integrated button. After the reset is completed, the device will reboot and a RED solid led is showed.

Please use this procedure only when the network primary controller is missing or otherwise inoperable

INFO: If the reset is performed while the device is still part of a network, it notifies the other devices that it has been removed (Device Reset Locally Notification).

Firmware Update

The system supports over-the-air firmware updates that do not require the device to be removed from its location. The firmware update can be activated from all certified controllers supporting version 2 of the Firmware Update function.

WARNING: The system will be rebooted at the end of the firmware update procedure. It is advisable to carry out the firmware update procedure only when necessary and following careful planning of the intervention.

Configurations
Input Configuration

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

1

| 1| IN1_TYPE|

1

| Define the 1st input type

Parameters Values                         Min: 0         Max: 2

Value

| Description

0

| no switch input

1

| momentary switch (button)

2

| toggle switch

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

2

| 1| IN2_TYPE|

1

| Define the 2nd input type

Parameters Values                         Min: 0         Max: 2

Value

| Description

0

| no switch input

1

| momentary switch (button)

2

| toggle switch

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

10

| 1| IN1_TOGGLE|

15

| Define which events on the input 1 toggle output 1.

Parameters Values                         Min: 0        Max: 31

Value

| Description

0

| Disabled

1

| 1 click

2

| 2 clicks

4

| 3 clicks

8

| Hold down

16

| Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default Value: 1 click, 2 clicks, 3 clicks, Hold down→15

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

11

| 1| IN1_ON_EXCLUSION|

0

| Define which events on the input 1 do not switch-On output 1.

Parameters Values                         Min: 0         Max: 31

Value

| Description

0

| Disabled

1

| 1 click

2

| 2 clicks

4

| 3 clicks

8

| Hold down

16

| Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default Value: Disable →0

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

12

| 1| IN1_OFF_EXCLUSION|

0

| Define which events on the input 1 do not switch-Off output 1.

Parameters Values                         Min: 0         Max: 31

Value

| Description

0

| Disabled

1

| 1 click

2

| 2 clicks

4

| 3 clicks

8

| Hold down

16

| Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default Value: Disable →0

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

15

| 1| IN2_TOGGLE|

15

| Define which events on the input 2 toggle output 2.

Parameters Values                         Min: 0         Max: 31

Value

| Description

0

| Disabled

1

| 1 click

2

| 2 clicks

4

| 3 clicks

8

| Hold down

16

| Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default Value: 1 click, 2 clicks, 3 clicks, Hold down→15

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

16

| 1| IN2_ON_EXCLUSION|

0

| Define which events on the input 2 do not switch-On output 2.

Parameters Values                         Min: 0         Max: 31

Value

| Description

0

| Disabled

1

| 1 click

2

| 2 clicks

4

| 3 clicks

8

| Hold down

16

| Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default Value: Disable →0

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

17

| 1| IN2_OFF_EXCLUSION|

0

| Define which events on the input 2 do not switch-Off output 2.

Parameters Values                         Min: 0         Max: 31

Value

| Description

0

| Disabled

1

| 1 click

2

| 2 clicks

4

| 3 clicks

8

| Hold down

16

| Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default Value: Disable →0

Output Configuration:

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

21

| 1| OUT1_TYPE|

0

| Define the 1st output type.

Parameters Values                         Min: 0         Max: 1

Value

| Description

0

| direct load or normally Open relay

1

| normally Closed relay

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

22

| 1| OUT2_TYPE|

0

| Define the 2nd output type.

Parameters Values                         Min: 0         Max: 1

Value

| Description

0

| direct load or normally Open relay

1

| normally Closed relay

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

23

| 1| STARTUP_OUT1|

2

| Define the 1st output level on startup
(status of the device following a restart)

Parameters Values                         Min: 0         Max: 3

Value

| Description

0

| OFF

1

| ON

2

| Previous status

3

| equal to input (ON if input close, OFF if input open)

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

24

| 1| STARTUP_OUT2|

2

| Define the 2nd output level on startup
(status of the device following a restart)

Parameters Values                         Min: 0         Max: 3

Value

| Description

0

| OFF

1

| ON

2

| Previous status

3

| equal to input (ON if input close, OFF if input open)

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

25

| 1| LOCAL_SCENE|

0

| Define the Local scene configuration.

Parameters Values                         Min: 0         Max: 2

Value

| Description

0

| independent channel
(External switch I1 controls output 1 load and external switch I2 controls output 2 load)

1

| never both on
(Both outputs can be OFF but they can never be ON simultaneously)

2

| Sequencing
(Outputs are toggled in this order: both loads ON, only load 1 ON, only load 2 ON, both loads OFF)

Timer management

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

30

| 1| TIMER_CH1_SETUP|

0

| Define which trigger event on the Channel 1 activate its timers when output 1 has changed

Parameters Values                         Min: 0         Max: 127

Value

| Description

0

| disabled

1

| 1 click

2

| 2 clicks

4

| 3 clicks

8

| Hold down

16

| Up

32

| Network (status change trigger by gateway or other devices in the Z-Wave™ network)

64

| System (based on the startup status, or other timer event)
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
To control the load with 1 click and 2 clicks -> Parameter value must be 1 + 2 =3
Default value: Disabled → 0

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

31

| 4| OFF_EP1_VALUE|

0

| Time in tenth of seconds after which the output 1 will be switched Off.

Parameters Values                         Min: 0         Max: 360000

Value

| Description

0-360000

| Specific time expressed in tenth of seconds for Status change

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

32

| 4| ON_EP1_VALUE|

100

| Time in tenth of seconds after which the output on Channel 1 will be switched On

Parameters Values                         Min: 0         Max: 360000

Value

| Description

0-360000

| Specific time expressed in tenth of seconds for Status change

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

33

| 1| TIMER_CH2_SETUP|

0

| Define which trigger events on the Channel 2 activate its timers when output 2 has changed

Parameters Values                         Min: 0         Max: 127

Value

| Description

0

| disabled

1

| 1 click

2

| 2 clicks

4

| 3 clicks

8

| Hold down

16

| Up

32

| Network (status change trigger by gateway or other devices in the Z-Wave™ network)

64

| System (based on the startup status, or other timer event)
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example: To control the load with 1 click and 2 clicks - > Parameter value must be 1 + 2 =3
Default Value: Disabled → 0

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

34

| 4| OFF_EP2_VALUE|

50

| Time in tenth of seconds after which the output on Channel 2 will be switched Off

Parameters Values                         Min: 0         Max: 360000

Value

| Description

0-360000

| Specific time expressed in tenth of seconds for Status change

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

35

| 4| ON_EP2_VALUE|

50

| Time in tenth of seconds after which the output on Channel 2 will be switched On

Parameters Values                         Min: 0         Max: 360000

Value

| Description

0-360000

| Specific time expressed in tenth of seconds for Status change

Association group management

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

40

| 1| G1_EP1_SETUP|

1

| Define which events on the input 1 control G1 association group on Channel

Parameters Values                         Min: 0         Max: 31

Value

| Description

0

| No control

1

| 1 click

2

| 2 clicks

4

| 3 clicks

8

| Hold down

16

| Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default value: 1 click →1

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

41

| 1| G2_EP1_SETUP|

2

| Define which events on the input 1 control G2 association group on Channel

Parameters Values                         Min: 0         Max: 31

Value

| Description

0

| No control

1

| 1 click

2

| 2 clicks

4

| 3 clicks

8

| Hold down

16

| Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default value: 2 clicks →2

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

42

| 1| G1_EP2_SETUP|

1

| Define which events on the input 2 control G1 association group on Channel 2.

Parameters Values                         Min: 0         Max: 31

Value

| Description

0

| No control

1

| 1 click

2

| 2 clicks

4

| 3 clicks

8

| Hold down

16

| Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default value: 1 click →1

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

43

| 1| G2_EP2_SETUP|

2

| Define which events on the input 2 control G2 association group on Channel 2.

Parameters Values                         Min: 0         Max: 31

Value

| Description

0

| No control

1

| 1 click

2

| 2 clicks

4

| 3 clicks

8

| Hold down

16

| Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default value: 2 clicks →-2

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

44

| 1| G1_EP1_ASS_VALUE|

101

| The value used to control G1 association group on Channel 1.

Parameters Values                         Min: 0         Max: 102

Value

| Description

0-99

| specific value

100

| ON

101

| propagate (output 1 status to the associated device)

102

| toggle remote (change status ON/OFF of associate devices)

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

45

| 1| G2_EP1_ASS_VALUE|

101

| The value used to control G2 association group on Channel 1.

Parameters Values                         Min: 0         Max: 102

Value

| Description

0-99

| specific value

100

| ON

101

| propagate (output 1 status to the associated device)

102

| toggle remote (change status ON/OFF of associate devices)

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

46

| 1| G1_EP2_ASS_VALUE|

101

| The value used to control G1 association group on Channel 2.

Parameters Values                         Min: 0         Max: 102

Value

| Description

0-99

| specific value

100

| ON

101

| propagate (output 1 status to the associated device)

102

| toggle remote (change status ON/OFF of associate devices)

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

47

| 1| G2_EP2_ASS_VALUE|

101

| The value used to control G2 association group on Channel 2.

Parameters Values                         Min: 0         Max: 102

Value

| Description

0-99

| specific value

100

| ON

101

| propagate (output 1 status to the associated device)

102

| toggle remote (change status ON/OFF of associate devices)

Meter management

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

70

| 2| E_REPORT_DELAY|

600

| Time in seconds after which the next Energy report will be sent

Parameters Values                         Min: 60         Max: 36000

Value

| Description

60-36000

| Report generation in a specific time in seconds

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

71

| 2| W_REPORT_DELAY|

600

| Time in second after which the next Power report will be sent

Parameters Values                         Min: 60         Max: 36000

Value

| Description

60-36000

| Report generation in a specific time in seconds

Parameter Number

| Size| Parameter Name|

Default Value

| Description
---|---|---|---|---

75

| 1| W_ISTANT_REPORT|

30

| The percentage change from the last sent report that trigger a new Power report

Parameters Values                         Min: 0         Max: 100

Value

| Description

0-100

| Report generation in a specific time in seconds

Disposing the devices

This product bears the selective sorting symbol for waste electrical and electronic equipment (WEEE).

This means that this product must be handled pursuant to European Directive 2002/96/EC in order to be recycled or dismantled to minimize its impact on the environment.

For further information, please contact your local or regional authorities.

Electronic products not included in the selective sorting process are potentially dangerous for the environment and human health due to the presence of hazardous substances.

Compliance with directives

Smart Serie 7 devices are built in compliance with directives 2014/53/EU and 2011/65/EU.

WiDom Srl shall not be held responsible for any damage caused by these devices if they are used in a manner that is not compliant with the instructions in this manual. WiDom Srl reserves the right to make any changes to the product that it considers necessary or useful without jeopardizing its primary features.

Warranty

For detailed information on the warranty please refer to the Standard Warranty Conditions indicated in company’s website at www.widom.it.

Please check at www.widom.it the newest version of this document.

WiDom Srl reserves the right to change product features and specifications at any time without notice, and is not responsible for typographical or graphical errors that may appear in this document.

Smart Double Switch L 7 Operating Instructions – www.widom.it

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals