Steinel L 810 LED iHF Z-Wave STEEL810 Manual

June 8, 2024
STEINEL

Steinel

L 810 LED iHF Z-Wave

SKU: STEEL810

Quickstart

This is a ****

Light Dimmer
for
Europe
.

To run this device please connect it to your mains power supply.

Add To start the light‘s inclusion mode, briefly press button SET.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

A high-quality product is cleverly thought through and made from materials that last. Its value also extends beyond today, it has permanency and constancy. The L 810 iHF outdoor SensorLight is an LED uplight and downlight that translates intelligent technology into form and function. For the first time, we have managed to make a light‘s sensor completely invisible without compromising on first-class design and technological perfection. For stunning upward and downward lighting. New: optional manual override for 4 hours. Smart home included.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This
procedure should only be used when the primary controller is inoperable.

  1. Briefly press button SET and directly afterwards keep it pressed for 5 seconds.
  2. Status LED briefly flashes to show that the light has been reset.
  3. The device is now no longer included in the Z-Wave system and has been returned to factory settings.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Installation

To achieve the stated reach of 5 m, the light should” be mounted at a height of approx. 2 m.”

Connecting the mains supply lead” (see illustration)”

The supply lead consist of three wires:

L= Phase conductor (usually black, brown or grey)

N= Neutral conductor (usually blue)

PE = Protective-earth conductor (green/yellow)

If you are in any doubt, identify the conductors using” a voltage tester; then disconnect from the power” supply again. Phase (L) and neutral (N) conductor” are connected to the terminal block.

Important: incorrectly wired connections will” produce a short circuit later on in the product or” your fuse box. In this case, you must identify the individual conductors once again and reconnect” them. A mains switch for switching the light ON and

OFF can of course be fitted in the mains lead.”

Note: to connect the light, the light enclosure” must be fitted on the mounting hooks to prevent” the internal wiring from being exposed to strain.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

Add To start the light‘s inclusion mode, briefly press button SET

Exclusion

Remove To start the light‘s exclusion mode, briefly press button SET

Product Usage

Detection zones for wall mounting:

  1. Minimum reach (1 m)

  2. Maximum reach (5 m)

The sensor-switched light can be put into service” after mounting the enclosure and connecting to” the mains power supply. The light will also work” without being integrated into a Z-Wave network.” In this case, the time setting is permanently set” to 3 minutes. When putting the light into operation,” the light will switch OFF after the 10-second” calibration phase and is then activated for sensor” mode. This light can now be integrated into the” Z-Wave network.

The settings can be made via the control dials or” via Z-Wave network. The settings last selected will” always be in effect regardless of whether they were” made via the control dials or via Z-Wave network.

Reach setting (sensitivity)

Factory setting: 5 m

Reach can be infinitely varied from 1 m to 5 m

Reach is the term used to describe the radius of” the detection zone produced on the ground when” mounting the light at a height of 2 m.

Twilight setting (response threshold)

Factory setting: 2000 lux

The chosen response threshold can be infinitely” varied from approx. 2–2000 lux.

Programme setting

0 = no basic light level ON from” twilight setting selected

10 = basic light level 10 minutes

30 = basic light level 30 minutes”
Moon = basic light level all night long

What is basic light level?

The basic light level provides continuous nighttime” illumination at approx. 10% light output. The” light only switches to maximum output (100%) for” the time selected in response to movement in the” detection zone. The light then returns to the basic”

light level (approx. 10%).”

Note: depending on the local power grid, the LEDs may flicker slightly when dimmed. This is not a” product defect and no reason for complaint.

What is soft light start?

The sensor-switched light features a soft light start” function. This means that when turned ON, the” light is not switched directly to maximum output” but gradually builds up brightness to 100% within” the space of a second. Brightness is also gradually

reduced when the light is switched OFF.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 1 Z-Wave Plus Lifeline
2 16 On/Off Control-Basic Set
3 16 Motion begin/end – Notifications
4 16 Ambient light- Multilevel Sensor Report

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: TIME

Duration of light after motion detection.
Size: 2 Byte, Default Value: 180

SettingDescription

5 – 900 seconds

Parameter 2: LIGHT

Light threshold [ lx ]Value can be controlled via potentiometer – potentiometer value isused as the default value and any potentiometer movement rewritesthe current setting.
Size: 2 Byte, Default Value: 2000

SettingDescription

0 run Learn ambient light sequence (the level is set automatically)
2 – 1999 lux
2000 2000 – is used as daylight ( always night mode)

Parameter 3: DIM

Night dim mode and time [min]Dim mode is also disabled when local control is disabled (as well as in Slave mode)
Size: 1 Byte, Default Value: 0

SettingDescription

0 off (dim = basic light completely disabled)
1 – 60 time [minutes] (enabled in night mode, starts after lamp is switched

off after motion detection)
-1| whole night (dim through the whole night when lamp is off)

Parameter 4: RANGE

Motion Radar Range [cm]Value can be controlled via potentiometer – potentiometer value isused as the default value and any potentiometer movement rewritesthe current setting
Size: 2 Byte, Default Value: 500

SettingDescription

100 – 500 cm

Parameter 6: BRIGHTNES MEAS INTERVAL

Brightness measuring interval [ minutes ]Interval for ambient light measuring when lamp is on ( lamp switchesoff shortly and measures ). 0=function is off
Size: 1 Byte, Default Value: 0

SettingDescription

0 function is off
5 – 120 minutes

Parameter 8: GLOBAL_LIGHT

_Use External Ambient Light ValueWhen GLOBALLIGHT mode is ON – device overrides its own lightsensor values and uses Light report values from any Z-Wave lightsensor instead – this has to be configured appropriately to send lightautomatically.If the last remote light level value is older than 30 minutes, the internallight value is used again until the next external value is received.
Size: 1 Byte, Default Value: 1

SettingDescription

0 OFF function
1 ON function

Parameter 9: SLAVE_MODE

_Can disable sensor controllu201cStupidu201d mode (bit 2 = 1): – has higher priority then slave mode. – lamp is permanently on (usefull for simple power wall switch controlling).Slave mode ( bit 0 = 1 ):- only if included in Z-Wave network- usefull for controlling via third-party sensor- lamp is directly controlled via Z-Wave, internal sensors are not used for controlling it.Central unit checking ( bit 1 = 1 ):( usefull especialy for controlling via gateway ) When Slave bit is 0:- lamp signalises fail of lifeline connection ( if this bit is zero fail of lifeline connection is not signalised ) When slave bit is 1:- lamp checks presence of Z-Wave device in lifeline group ( gateway ). If it is not present for 2 minutes ( testing repeatedly every 30 seconds ) device switches to normal mode in the same way as after the end of local disabled mode ( ONBEHAVIOUR )- The device checks every 1 minute for recovery of Lifeline connection.- if no lifeline specified – it works in normal modeBe careful with this option, lamp stops using itu2019s own motion sensor in Slave and Stupid mode.
Size: 1 Byte, Default Value: 2

SettingDescription

0 Normal mode
1 Slave mode without gateway checking
2 Normal mode with lifeline error signalisation
3 Slave mode with gateway checking
4 Stupid mode – lamp permanetly on

Parameter 10: OFF_BEHAVIOUR

Behaviour after BASIC OFF ( and similar commands ).If a transition ( even with zero change ) with a non-default duration isto be processed, the transition cannot be interrupted by any motionevent in any case.for values 1-209 – Lamp is switched off and remains so until after a specified timeout once a new motion event (local or remote) is received.
Size: 2 Byte, Default Value: 10

SettingDescription

0| Lamp is switched off and remains so until any new motion event (local or remote) is received.
---|---
1 – 100| timeout: 1 second (1) to 100 seconds (100) in 1-second resolution
101 – 200| timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution
201 – 209| timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution
255| Lamp is switched off for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation

Parameter 11: ON_BEHAVIOUR

Behaviour after BASIC ON (and similar commands).If a transition (even with zero change) with a non-default duration is to be processed, the transition cannot be interrupted by any motion event in any case.for values 1-209 – Lamp is switched on and remains so until after a specified timeout once a new motion event (local or remote) is received. It then works normally via current motion evaluation.
Size: 2 Byte, Default Value: 255

SettingDescription

0| Lamp is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled.
---|---
1 – 100| timeout: 1 second (1) to 100 seconds (100) in 1-second resolution
101 – 200| timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution
201 – 209| timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution
255| Lamp is switched on for TIME (cfg 1). It does not wait for a motion event and works normally via current motion evaluation.

Parameter 12: ON_TIME_OVER

_Time limit to stop waiting for motion after timeout of ON_BEHAVIOURor OFF_ONBEHAVIOUR ( 0-209 ) to prevent staying ON forever whenis no motion.
Size: 2 Byte, Default Value: 204

SettingDescription

0 o additional waiting for motion.
1 – 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution
101 – 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution
201 – 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution
255 Never stop waiting before motion.

Parameter 13: ON_OFF_BEHAVIOR

_Behaviour after after a rapid sequence of BASIC ON and BASIC OFF commands.The intention is to use a much longer timeout value than the time after a single ON command which should then be followed by a short timeout value.The behaviour is almost the same as for parameter 10 (OFF_LOCALDISABLE) for values 1-209 – Lamp is switched off and remains so until after a specified timeout once a new motion event (local or remote) is received.
Size: 2 Byte, Default Value: 204

SettingDescription

0| Lamp is switched off and remains so until any new motion event (local or remote) is received.
---|---
1 – 100| timeout: 1 second (1) to 100 seconds (100) in 1-second resolution
101 – 200| timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution
201 – 209| timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution
255| device ignores ON – OFF sequence and uses OFF behavior

Parameter 14: OFF_ON_BEHAVIOUR

Behaviour after after a rapid sequence of BASIC OFF and BASIC ONcommands.The intention is to use a much longer timeout value than the time aftera single OFF command which should then be followed by a shorttimeout value.The behaviour is amost the same as for parameter 11for values 1-209 – Lamp is switched on and remains so until after a specified timeout once a new motion event (local or remote) is received. It then works normally via current motion evaluation.
Size: 2 Byte, Default Value: 204

SettingDescription

0| Lamp is switched on and remains so until any new motion event (local or remote) is received. It then works normally via current motion evaluation. Notice – during the day, this mode cannot be ended remotely due to motion events not being transmitted – only via local motion sensor if enabled.
---|---
1 – 100| timeout: 1 second (1) to 100 seconds (100) in 1-second resolution.
101 – 200| timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution
201 – 209| timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution
255| device ignores OFF – ON sequence and uses ON behaviour

Parameter 15: SEQUENCY_TIME

Time in [ 100 miliseconds ] of maximum delay between BASIC ONand BASIC OFF ( and vice versa ) to consider this as a sequence. It istypically 1 second, but can be exceptionally longer due to retransmissionsand overload – in this case, a longer interval can be allowed ( upto 5 seconds ).
Size: 1 Byte, Default Value: 255

SettingDescription

10 – 50 tenth of second

Parameter 16: MOTION_DISABLE

Motion disable timeout after BASIC SET to motion endpoint when theinternal motion sensor is not used for evaluating the behaviour of thelamp and groups 2 and 3. Events are, however, still transmitted to theLifeline, and the lamp can be controlled via remote motion sensors.for values 1-209 – Internal motion sensor is disabled for specified timeout after BASIC SET 0x00 to Motion endpoint.
Size: 2 Byte, Default Value: 0

SettingDescription

0 BASIC SET to Motion endpoint ignored, Motion sensor still enabled
1 – 100 timeout: 1 second (1) to 100 seconds (100) in 1-second resolution
101 – 200 timeout: 1 minute (101) to 100 minutes (200) 1-minute resolution
201 – 209 timeout: 1 hour (201) to 9 hours (209) in 1-hour resolution
255 BASIC SET to Motion endpoint ignored, Motion sensor still disabled

Technical Data

Dimensions 91 x 230 x 145 mm
Weight 1092 gr
Hardware Platform ZM5202
EAN 4007841029869
IP Class IP 44
Voltage 230 V
Device Type Light Dimmer Switch
Network Operation Always On Slave
Z-Wave Version 6.51.09
Certification ID ZC10-17045557
Z-Wave Product Id 0x0271.0x0001.0x1A75
Neutral Wire Required ok
Sensors LuminanceMotion/No Motion (Binary)
Z-Wave Scene Type Scene
Firmware Updatable Updatable by Consumer by RF
IP (Ingress Protection) Rated ok
Outdoor Use ok
Supported Notification Types Home SecuritySystem
Electric Load Type Dimmable LEDLED
Frequency Europe – 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Switch All
  • Application Status
  • Association Grp Info
  • Association V2
  • Basic
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V3
  • Manufacturer Specific
  • Multi Channel V4
  • Multi Channel Association V2
  • Node Naming
  • Notification V4
  • Powerlevel
  • Scene Activation
  • Scene Actuator Conf
  • Sensor Multilevel V4
  • Switch Multilevel V4
  • Version V2
  • Zwaveplus Info V2

Controlled Command Classes

  • Basic

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals