Popp POPP Wall Controller 2 POPE700861 Manual
- June 8, 2024
- POPP
Table of Contents
- Popp
- POPP Wall Controller 2
- SKU: POPE700861
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Product Usage
- Node Information Frame
- Quick trouble shooting
- Association – one device controls an other device
- Configuration Parameters
- Parameter 1: Button 1 and 3 pair mode
- Parameter 2: Button 2 and 4 pair mode
- Parameter 11: Command to control Group A
- Parameter 12: Command to control Group B
- Parameter 13: Command to control Group C
- Parameter 14: Command to control Group D
- Parameter 21: Send the following switch all commands
- Parameter 22: Invert buttons
- Parameter 25: Blocks wake up even when Wake Up Interval is set
- Parameter 30: Send unsolicited battery report on Wake Up
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Popp
POPP Wall Controller 2
SKU: POPE700861
Quickstart
This is a
secure
Z-Wave Device
for
Europe.
To run this device please insert fresh *1 CR2032** batteries.
Please make sure the internal battery is fully charged.
On factory default state pushing any button for one seconds starts inclusion (red/green LED blinking fast). This behavior can be used to test the factory default or exclusion state.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
The Popp Wall Controller is a Z-Wave device that can both control other Z-Wave devices and activate predefined scenes in an IP gateway. Although it is controlling other devices, the Wall Controller cannot act as Z-Wave network controller (primary or secondary) and will always need a Z-Wave network controller to be included into a Z-Wave network. The device can be used in different modes that are selected by configuration parameters:
- Control of groups of other Z-Wave devices using “ON”, “OFF” and Dim commands.
- Activation of predefined scenes in Gateways or other Z-Wave devices.
The wall controller must be completed by a mounting frame, the wall switch frame and a rocker. They are not scope of delivery of this device.
This device support secure communication when included by a controller that also supports secure communication. The device will then send all commands as secure commands unless the receiving device can not accept them. Then the command is send the normal way automatically.
The device will be completed with different designs of wall frame and rockers.”
For example:”
- Berker (S.1, B.1, B.3, B.7 Glass),
- GIRA (System 55, Standard 55, E2, E22, Event, Esprit),
- Merten (1-M, Atelier-M, M-Smart, M-Arc, M-Star, M-Plan),
- Schneider Electric Exxact,
- Jung (A 500, AS 500, A plus, A creation)
- Kopp HK07
”
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
The device can be set back to factory defaults without performing an exclusion process. Please executes the following steps: (1) Turn the device into Management Mode, (2) click on Button 3, (3) keep button 4 pushed for 4 seconds.
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is
not used.
Do not mix batteries of different charging level or different brands.
Installation
The device can be mounted on every dry and flat surface using either screws or double side adhesive. First the mounting base is fixed on the wall. Next step the switch frame is placed on the 2 frame and the electronic insert is used to fix the frame to the mounting base as shown on the image. Finally the switching paddle(s) are mounted on the electronic base.
For battery change, the switching paddle(s) need to be removed. The CR battery can be replaced by pushing the little nipple above the battery. The old battery will slide out and the new battery is inserted until the nipple will hold it again.
The device can be operated in two different modes:
- Operation Mode: ” This is the mode where the device is controlling other Z-Wave devices or is activating scenes.
- Management Mode: ” The device is turned into the management mode by pushing all four buttons for 5 sec. A blinking green LED indicates the management mode. In the management mode the buttons of the device have different functions. If no further action is performed, the device will turn back to the normal mode after 10 sec. Any management action terminates the management mode as well.
In management mode the following actions can be performed:
- Button 1 ” – Re-Inclusion/Exclusion: Every re-inclusion or exclusion attempt is confirmed by hitting this button. Any button press stops the mode as well.
- Button 2 ” – Send Node Information Frame and Wake up Notification. (see explanation below)
- Button 3 ” – Factory Default Reset. After clicking on button 3 keep button 4 pushed for >4 seconds
- Button 4 ” – Enter into Association mode to assign target devices to one of the four association. Refer to the manuals section about association for more information how to set and unset association groups.
”
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
In Factory Default hit” upper” left button ” (secure) or” upper right button (unsecure). After factory default you need to enter Management Mode (all four buttons for one second until green LED blinks) before using the buttons
Exclusion
Enter Management Mode (all four buttons for one second until green LED blinks), then hit the upper left button
Product Usage
Depending on the button mode and operating modes configured using the configuration parameters the key fob can be used in different ways.
Button modes:
4 Groups are controlled with single button (parameter 1/2 = 0) ” The four buttons 1-4 control one single control group each: 1->A, 2->B, 3->C, 4->D. Single click turns devices in the control group on, double click turns them off. Click and hold can be used for dimming.
2 Groups are controlled with two buttons (parameter 1/2 = 1) ” The buttons 1 and 3 control the control group A (button on turns on, buttons turns off), the buttons 2 and 4 control the control group B (button on turns on, buttons turns off). In case dimmers are controlled, holding down the larger button will dim up, holding down the smaller button will dim down the load. Releasing the button will stop the dimming function.
4 Groups are controlled with two buttons and double click (parameter 1/2 = 2) ” This mode enhances the previous mode and allows to control two further control groups C and D using double clicks.
Operating modes:
The devices supports 8 different operating modes – this means the kind of command sent out when pushing a button. Operating modes either directly control other devices or they issue various scene activation commands to a central controller. Operating modes for direct device control are:
- Direct Control of associated devices with On/Off/Dim commands (parameter 11…14 = 1). Devices are controlled using Basic Set On/Off commands and SwitchMultilevel Dim Start/Stop. This mode implements communication pattern” 7.
- Direct Control of associated devices with only On/Off commands (parameter 11…14 = 2). Devices are controlled using only Basic Set On/Off commands. On dimming Up event On is sent, on dimming Down Off is sent. This mode also implements communication pattern” 7.
- Switch All commands (parameter 11…14 = 3) ” In this mode a” all neighbouring devices ” will receive SwitchAll Set On/Off command and interpret it according to their membership in SwitchAll groups. This mode implements communication pattern” 7.
- Door Lock Control (parameter 11…14 = 7) ” This modes allows direct control (open/close) of electronic door locks using secure communication. The mode implements communication pattern” 7.
Operating modes for scene activation are:
- Direct Activation of preconfigured scenes (parameter 11…14 = 5) ” Associated devices in an association group are controlled by individual commands defines by Z-Wave command class ?Scene Controller Configuration?. This mode enhances mode” Direct Control of associated devices with On/Off/Dim commands ” and implements communication patterns” 6 ” and” 7. Please turn the button mode to “seperate” to allows different scene id on every button.
- Scene Activation in IP Gateway (parameter 11…14 = 4) ” If configured correctly the buttons can trigger a scene in a gateway. The scene number triggered is a combination of the group number and the action performed on the button and has always two digits. The group number defines the upper digit of the scene number, the action the lower digit. The following actions are possible:
- 1 = On
- 2 = Off
- 3 = Dim Up Start
- 4 = Dim Down Start
- 5 = Dim Up Stop
- 6 = Dim Down Stop
Example: Clicking/double clicking the button will issue scene triggers, scene 11 (button 1 click, event on), scene 12 (button double click 1, event off, single button control is used in this example)
- Activation of Central Scenes (parameter 11…14 = 8,Default) ” Z-Wave Plus introduces a new process for scene activation – the central scene control. Pushing a button and releasing a button sends a certain command to the central controller using the lifeline association group. This allows to react both on button push and button release. This mode implements communication patterns” 6 ” but requires a central gateway supporting Z-Wav Plus.
Node Information Frame
The Node Information Frame (NIF) is the business card of a Z-Wave device. It
contains
information about the device type and the technical capabilities. The
inclusion and
exclusion of the device is confirmed by sending out a Node Information Frame.
Beside this it may be needed for certain network operations to send out a Node
Information Frame. To issue a NIF execute the following action:
Pressing Button 2 in management mode will issue a Node Information Frame.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1 | 10 | Lifeline |
---|---|---|
2 | 10 | Control Group A |
3 | 10 | Control Group B |
4 | 10 | Control Group C |
5 | 10 | Control Group D |
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 1: Button 1 and 3 pair mode
In separate mode button 1 works with Group A, button 3 with Group C. Click
is ON, Hold is dimming UP, Double click” is OFF, Click-Hold is dimming DOWN.
In pair button 1/3 are UP/DOWN correspondingly. Click is ON/OFF, Hold is”
dimming UP/DOWN. Single clicks works with Group A, double click with Group C.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | Separately |
---|---|
1 | In pair without double clicks |
2 | In pair with double clicks |
Parameter 2: Button 2 and 4 pair mode
In separate mode button 2 works with control group B, button 4 with control
group D. Click is ON, Hold is dimming UP,” Double click is OFF, Click-Hold is
dimming DOWN. In pair button B/D are UP/DOWN correspondingly. Click is”
ON/OFF, Hold is dimming UP/DOWN. Single clicks works with Group B, double
click with Group D.
Size: 1 Byte, Default Value: 1
SettingDescription
0 | Separately |
---|---|
1 | In pair without double clicks |
2 | In pair with double clicks |
Parameter 11: Command to control Group A
This parameter defines the command to be sent to devices of control group A
when the related button is pressed.
Size: 1 Byte, Default Value: 8
SettingDescription
0 | Disable |
---|---|
1 | Switch on/off and Dim (send Basic Set and Switch Multilevel) |
2 | Switch on/off only (send Basic Set) |
3 | Switch all |
4 | Send scenes |
5 | Send preconfigured scenes |
6 | Control devices in proximity |
7 | Control door lock |
8 | Central scene to gateway (default) |
Parameter 12: Command to control Group B
This parameter defines the command to be sent to devices of control group B”
when the related button is pressed.
Size: 1 Byte, Default Value: 8
SettingDescription
0 | Disable |
---|---|
1 | Switch on/off and Dim (send Basic Set and Switch Multilevel) |
2 | Switch on/off only (send Basic Set) |
3 | Switch all |
4 | Send scenes |
5 | Send preconfigured scenes |
6 | Control devices in proximity |
7 | Control door lock |
8 | Central scene to gateway (default) |
Parameter 13: Command to control Group C
This parameter defines the command to be sent to devices of control group C
when the related button is pressed.
Size: 1 Byte, Default Value: 8
SettingDescription
0 | Disable |
---|---|
1 | Switch on/off and Dim (send Basic Set and Switch Multilevel) |
2 | Switch on/off only (send Basic Set) |
3 | Switch all |
4 | Send scenes |
5 | Send preconfigured scenes |
6 | Send preconfigured scenes |
7 | Control door lock |
8 | Central scene to gateway |
Parameter 14: Command to control Group D
This parameter defines the command to be sent to devices of control group D
when the related button is pressed.
Size: 1 Byte, Default Value: 8
SettingDescription
0 | Disable |
---|---|
1 | Switch on/off and Dim (send Basic Set and Switch Multilevel) |
2 | Switch on/off only (send Basic Set) |
3 | Switch all |
4 | Send scenes |
5 | Send preconfigured scenes |
6 | Control devices in proximity |
7 | Control door lock |
8 | Central scene to gateway (default) |
Parameter 21: Send the following switch all commands
__
Size: 1 Byte, Default Value: 1
SettingDescription
1 | Switch off only |
---|---|
2 | Switch on only |
255 | Switch all on and off |
Parameter 22: Invert buttons
__
Size: 1 Byte, Default Value: 0
SettingDescription
0 | No |
---|---|
1 | Yes |
Parameter 25: Blocks wake up even when Wake Up Interval is set
If the KFOB wakes up and there is no controller nearby, several unsuccessful
communication attempts will drain” battery.
Size: 1 Byte, Default Value: 0
SettingDescription
0 | Wake up is blocked |
---|---|
1 | Wake up is possible if configured accordingly |
Parameter 30: Send unsolicited battery report on Wake Up
__
Size: 1 Byte, Default Value: 1
SettingDescription
0 | No |
---|---|
1 | To same node as Wake Up Notification |
2 | Broadcast to neighbors |
Technical Data
Dimensions | 80 x 80 x 18 mm |
---|---|
Weight | 30 gr |
Hardware Platform | ZM5202 |
EAN | 4251295700861 |
IP Class | IP 20 |
Voltage | 3V |
Battery Type | 1 * CR2032 |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Scene Controller Conf
- Association Grp Info
- Device Reset Locally
- Central Scene
- Zwaveplus Info
- Configuration
- Manufacturer Specific
- Powerlevel
- Battery
- Wake Up
- Association
- Version
- Multi Channel Association
- Multi Cmd
- Security
Controlled Command Classes
- Basic
- Central Scene
- Switch Multilevel
- Switch All
- Scene Activation
- Multi Channel
- Door Lock
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>