Popp Z-Wave Wall Plug Type E Switch POP_123627 Manual

June 8, 2024
POPP

Popp

Z-Wave Wall Plug Type E Switch

SKU: POP_123627

Quickstart

This is a ****

On/Off Power Switch
for
Russia
.

To run this device please connect it to your mains power supply.

Inclusion and Exclusion are confirmed by a tripple click of the button.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

This is a switch plug that can be placed between a wall outlet Type E and electric devices, plugged in by cord. It can switch all electrical loads up to 3500 W. The device is IP 20 rated and can therefore only be used on dry environments. Switching is controlled wirelessly using Z-Wave or locally using a toggleing button. A blue LED indicates the switching status. An automatic “Off” function and programmable switching behavior make the device a very flexible tool for the inhouse lighting.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Installation

The plug can be plugged into every wall outlet for Plug-Type E. It is IP20 rated and can therefore only be used in dry environments. Do not locate the device facing direct sunlight, humid or dusty place. The suitable ambient temperature for the device is 0°C ~ 40°C. Plugs must not be stacked and operated.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

Inclusion and Exclusion are confirmed by a tripple click on the button.

Exclusion

Inclusion and Exclusion are confirmed by a tripple click on the button.

Product Usage

The device is able to switch electric loads up to 3500 W and can be switched wirelessly or using the local button.

Local Operation
The local button allowes to switch the device. A short press on the button toggles the switch. If it is in on state the button turns off and respective in off state the button turns on.

LED Usage
The device has one blue LED used to indicate status information. The behavior of the blue LED can be configured:

  • It may show the switching state. This is the default option.
  • It may serve as night light. So it is on when the light is off.
  • It is deactivated.
  • It can be controlled wirelessly and used as an indicator for other advanced functions.

Automated Switch-Off Function
If activated the switch will turn off automatically after a defined time. This function is particularly useful if the switch is turned on using a motion detector of any other type of sensor. In this case it is possible to further define the reaction of the switch on certain signals sent from a sensor. This allowes a very flexible application of the plug switch in the house.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 5 Send Reports on switch state change

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: LED mode

Set LED indication mode
Size: 1 Byte, Default Value: 01

SettingDescription

00 Disabled
01 Show switch state
02 Night mode (inverted switch state)
03 Operated by Indicator Command Class

Parameter 2: Automatically switch off after

If not zero, automatically switch off after a user defined time
Size: 2 Byte, Default Value: 0000

SettingDescription

0000 Disabled
0001 – ffff sec

Parameter 3: What to do on RF off command

Defines how to interpret RF Off command. Can be used in conjunction with Auto Off function: Ignore – to switch on the light by motion detectors and switch it off after some amount of time: in case of multiple motion detectors each would try to switch the light off that would break logics; Switch on – to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time. Button off click will still work (if button operations are not disabled).
Size: 1 Byte, Default Value: 00

SettingDescription

00 Switch off
01 Ignore
02 Switch on
03 Switch on if load is off else switch off

Parameter 5: Restore switch state after power cycle

Defines if the switch should restore switch state to the last state prior to device power off (power cycle).
Size: 1 Byte, Default Value: 01

SettingDescription

00 No, turn off
01 Yes

Technical Data

Dimensions 0.0590000×0.1010000×0.0750000 mm
Weight 130 gr
EAN 696859123627
Device Type On/Off Power Switch
Generic Device Class Binary Switch
Specific Device Class Binary Power Switch
Firmware Version 01.00
Z-Wave Version 03.2a
Certification ID ZC08-13070028
Z-Wave Product Id 0115.1100.0001
Frequency Russia – 868.4MHz, 869.85MHz
Maximum transmission power 5 mW

Supported Command Classes

  • Basic
  • Switch Binary
  • Version
  • Indicator
  • Switch All
  • Configuration
  • Manufacturer Specific
  • Protection
  • Node Naming
  • Association

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>