Philio Tech Z-Wave 3 in 1 Sensor (Door / Window, Illumination, Temperature) PHI_PST02-1C Manual
- June 8, 2024
- Philio Tech
Table of Contents
- Philio Tech
- Z-Wave 3 in 1 Sensor (Door / Window, Illumination, Temperature)
- SKU: PHI_PST02-1C
- Quickstart
- Important safety information
- What is Z-Wave?
- Product Description
- Prepare for Installation / Reset
- Installation
- Inclusion/Exclusion
- Node Information Frame
- Communication to a Sleeping device (Wakeup)
- Quick trouble shooting
- Firmware-Update over the Air
- Association – one device controls an other device
- Configuration Parameters
- Parameter 2: Basic Set Level
- Parameter 4: Light Threshold
- Parameter 5: Operation Mode
- Parameter 6: Mult-Sensor Function Switch
- Parameter 7: Customer Function
- Parameter 8: PIR Re-Detect Interval Time
- Parameter 9: Turn Off Light Time
- Parameter 10: Auto Report Battery Time
- Parameter 11: Auto Report Door/Window State Time
- Parameter 12: Auto Report Illumination Time
- Parameter 13: Auto Report Temperature Time
- Parameter 20: Auto Report Tick Interval
- Parameter 21: Temperature Differential Report
- Parameter 22: Illumination Differential Report
- Technical Data
- Supported Command Classes
- Controlled Command Classes
- Explanation of Z-Wave specific terms
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Philio Tech
Z-Wave 3 in 1 Sensor (Door / Window, Illumination, Temperature)
SKU: PHI_PST02-1C
Quickstart
This is a
secure
Alarm Sensor
for
Europe.
To run this device please insert fresh *1 CR123A** batteries.
Please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
- Have Z-Wave Controller entered inclusion mode.
- Pressing tamper key three times within 1.5 seconds to enter the inclusion mode.
- After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in
this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any
loss or damage resulting from failure to comply with the instructions in this
manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal
instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart
Home. This
device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message ( two-
way
communication) and every mains powered node can act as a repeater for other
nodes
( meshed network ) in case the receiver is not in direct wireless range of
the
transmitter.
This device and every other certified Z-Wave device can be used together
with any other
certified Z-Wave device regardless of brand and origin as long as both are
suited for the
same frequency range.
If a device supports secure communication it will communicate with other
devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to
maintain
backward compatibility.
For more information about Z-Wave technology, devices, white papers etc.
please refer
to www.z-wave.info.
Product Description
With the Philio 3-in-1 Sensor you can not only monitor your door’s and window’s status, because the device is equipped with 3 different sensors in total: Door/Window Sensor, Temperature Sensor, Light Sensor. The sensor consists of two parts: a detector and a magnet. The Magnet should be mounted on the door’s/window’s opening part and the detector on the fixed frame. Opening the door/window will remove the magnetic field, trigger the detector and generate an alarm condition, (if the system is armed).
The sensor can also be used for automatic light control, one possible scene is to get the illumination lux level from built-in light sensors and send a signal to Z-Wave control center to turn the light on once the door will be opened when the room is dark. Every time, when the door/window sensor triggers a status change, it will also send temperature and brightness value.
Features:
- Contact sensor monitors door and window status (open/closed)
- Measures and reports additional values for temperature and brightness
- Tamper protection
- Can be mounted on every planar surface in vertical or horizontal position
- Firmware update „Over The Air“ (OTA)
- Power Supply: Batterie (1x CR123A)
- Wireless Technology: Z-Wave Plus
- Dimensions: 28 x 95 x 35 mm
Download high resolution images for Philio products.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory
default
state. Please make sure to reset the device into factory default. You can do
this by
performing an Exclusion operation as described below in the manual. Every
Z-Wave
controller is able to perform this operation however it is recommended to use
the primary
controller of the previous network to make sure the very device is excluded
properly
from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave
controller. This
procedure should only be used when the primary controller is inoperable.
- Pressing tamper key four times within 1.5 seconds and do not release the tamper key in the 4th pressed, and the LED will light ON.
- After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second. Otherwise, the LED will flash once.
- IDs are excluded and all settings will reset to factory default.
.
Safety Warning for Batteries
The product contains batteries. Please remove the batteries when the device is
not used.
Do not mix batteries of different charging level or different brands.
Installation
Battery Installation
When the device report the low battery message. The user should replace the battery to new one. The battery type is CR123A, 3.0V. The way to open the front cover please follow below steps.
- Using a tool to press the 1-1 position, to release the cover.
- Hold the front cover and pull back
- Hold the front cover and pull up
Replace the new battery and install the cover back.
- Put the front cover bottom to 1-1, and press down.
- Push the front cover top to 2-1.
Choosing a Suitable Location
- The recommended mounting height is 160cm
- Don”t let the device facing the window or the sunlight.
- Don”t let the device facing the source of heat. For instance the heater or the air-condition.
Installation
- In the first time, add the device into the Z-WaveTM network. First, make sure the primary controller is in the inclusion mode. And then power on the device, just take out the insulation Mylar in the back side of the device. The device will auto start the NWI (Network Wide Inclusion) mode. And it should be included in 5 seconds. You will see the LED light ON one second.
- Let the controller associate with the device into the first group, any light switch that intend to be turned on when the device trig please associate with the device into the second group.
- In the accessory pack. There are two type of double coated tape, one is thicker (hereinafter referred to as A tape) and another is thinner (hereinafter referred to as B tape), you can use A tape for the test at the beginning. The right way for A tape installation is stick it to the position below tamper key. The thicker tape won”t let the tamper key pressed, so the sensor will enter the test mode, You may test if installed position is good or not by this way.
After finish the test and decide to fix, then you can remove tape A, and mounting the sensor by using tape B. The tamper key will pressed and let the sensor enter normal mode.
Inclusion/Exclusion
On factory default the device does not belong to any Z-Wave network. The
device needs
to be added to an existing wireless network to communicate with the
devices of this network.
This process is called Inclusion.
Devices can also be removed from a network. This process is called
Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network.
This
controller is turned into exclusion respective inclusion mode. Inclusion and
Exclusion is
then performed doing a special manual action right on the device.
Inclusion
- Have Z-Wave Controller entered inclusion mode.
- Pressing tamper key three times within 1.5 seconds to enter the inclusion mode.
- After add successful, the device will wake to receive the setting command from Z-Wave Controller about 20 seconds.
Exclusion
- Have Z-Wave Controller entered exclusion mode.
- Pressing tamper key three times within 1.5 seconds to enter the exclusion mode.
- Node ID has been excluded.
Node Information Frame
The Node Information Frame (NIF) is the business card of a Z-Wave device. It
contains
information about the device type and the technical capabilities. The
inclusion and
exclusion of the device is confirmed by sending out a Node Information Frame.
Beside this it may be needed for certain network operations to send out a Node
Information Frame. To issue a NIF execute the following action:
Press any key once, the device will awake 10 seconds.
Communication to a Sleeping device (Wakeup)
This device is battery operated and turned into deep sleep state most of the
time
to save battery life time. Communication with the device is limited. In order
to
communicate with the device, a static controller C is needed in the
network.
This controller will maintain a mailbox for the battery operated devices and
store
commands that can not be received during deep sleep state. Without such a
controller,
communication may become impossible and/or the battery life time is
significantly
decreased.
This device will wakeup regularly and announce the wakeup
state by sending out a so called Wakeup Notification. The controller can then
empty the mailbox. Therefore, the device needs to be configured with the
desired
wakeup interval and the node ID of the controller. If the device was included
by
a static controller this controller will usually perform all necessary
configurations. The wakeup interval is a tradeoff between maximal battery
life time and the desired responses of the device. To wakeup the device please
perform
the following action:
Press any key once, the device will awake 10 seconds.
Quick trouble shooting
Here are a few hints for network installation if things dont work as expected.
- Make sure a device is in factory reset state before including. In doubt exclude before include.
- If inclusion still fails, check if both devices use the same frequency.
- Remove all dead devices from associations. Otherwise you will see severe delays.
- Never use sleeping battery devices without a central controller.
- Dont poll FLIRS devices.
- Make sure to have enough mains powered device to benefit from the meshing
Firmware-Update over the Air
This device is capable of receiving a new firmware ‘over the air’. The update
function
needs to be supported by the central controller. Once the controller starts
the update
process, perform the following action to confirm the firmware update:
The device support the Z-Wave firmware update via OTA. Before starting the procedure, please remove the front cover of the device. Otherwise the hardware check will be failed. Let the controller into the firmware update mode, and then press the front tamper key once to start the update. After finish the firmware download, the LED will start flash in every 0.5 second. At that time, please don”t remove the battery, otherwise it will cause the firmware broken, and the device will no function. After the LED stop flash, it is recommended that the user power up the device. Caution: After remove the battery, please wait about 30
seconds, and then re-install the battery.
Association – one device controls an other device
Z-Wave devices control other Z-Wave devices. The relationship between one
device
controlling another device is called association. In order to control a
different
device, the controlling device needs to maintain a list of devices that will
receive
controlling commands. These lists are called association groups and they are
always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’
Command.
Association Groups:
Group NumberMaximum NodesDescription
1| 8|
Receiving the report message, like triggered event, temperature, illumination etc.
---|---|---
2| 8|
Light control, the device will send the “Basic Set” command
Configuration Parameters
Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock
further
enhanced features.
IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus
56.
In case of a two byte value the same logic applies: Values greater than 32768
may
needed to be given as negative values too.
Parameter 2: Basic Set Level
Setting the BASIC command value to turn on the light
Size: 1 Byte, Default Value: 255
SettingDescription
0 | turn off the light |
---|---|
1 – 100 | the light strength. |
254 | turn on the light. |
Parameter 4: Light Threshold
Setting the illumination threshold to turn on the light. When the event
triggered and the environment illumination lower then the threshold, the
device will turn on the light. 0 means turn off illumination detected
function. And never turn on the light.
Notice: In none test mode, only the value in 1 to 99 will enable the
illumination detected function and update the illumination value.
Size: 1 Byte, Default Value: 99
SettingDescription
0 | turn off illumination detected function. |
---|---|
1 – 100 | 1 means darkest. 99 means brightest. 100 means turn off illumination |
detected function. And always turn on the light.
Parameter 5: Operation Mode
Operation mode. Using bit to control.
Size: 1 Byte, Default Value: 0
SettingDescription
1 | Reserve. |
---|---|
2 | 1 means test mode, 0 means normal mode. Notice: This bit only effect by the |
DIP Switch setting to “customer mode”, otherwise it decides by DIP Switch
setting to Test or Normal Mode
4| Disable the door/window function. (1:Disable, 0:Enable)
8| Setting the temperature scale. 0: Fahrenheit, 1:Celsius
16| Disable the illumination report after event triggered. (1:Disable,
0:Enable)
32| Disable the temperature report after event triggered. (1:Disable,
0:Enable)
64| Reserve.
128| Disable the back key release into test mode. (1:Disable, 0:Enable)
Parameter 6: Mult-Sensor Function Switch
Multisensor function switch. Using bit to control.
Size: 1 Byte, Default Value: 4
SettingDescription
1| Disable magnetic integrate illumination to turn ON the lighting nodes in
the association group 2. (1:Disable, 0:Enable)
---|---
2| Reserve.
4| Reserve.
8| Reserve.
16| Disable delay 5 seconds to turn off the light, when door/window closed.
(1:Disable, 0:Enable)
32| Disable auto turn off the light, after door/window opened to turn on the
light. (1:Disable, 0:Enable)
64| Reserve.
128| Reserve.
Parameter 7: Customer Function
Customer function switch, using bit control.
Size: 1 Byte, Default Value: 4
SettingDescription
1 | Reserve. |
---|---|
2 | Reserve. |
4 | Reserve. |
8 | Disable send out BASIC OFF after door closed. (1:Disable, 0:Enable) |
16 | Notification Type, 0: Using Notification Report. 1: Using Sensor Binary |
Report.
32| Disable Multi CC in auto report. (1:Disable, 0:Enable)
64| Disable to report battery state when the device triggered. (1:Disable,
0:Enable)
128| Reserve.
Parameter 8: PIR Re-Detect Interval Time
In the normal mode, after the PIR motion detected, setting the re-detect
time. 8 seconds per tick, default tick is 3 (24 seconds).Setting the suitable
value to prevent received the trigger signal too frequently. Also can save the
battery energy.Notice: If this value bigger than the configuration setting NO.
9. There is a period after the light turned off and the PIR not start
detecting.
Size: 1 Byte, Default Value: 3
SettingDescription
1 – 127 | PIR Re-Detect Interval Time |
---|
Parameter 9: Turn Off Light Time
After turn on the lighting, setting the delay time to turn off the lighting
when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32
seconds).0 means never send turn off light command.
Size: 1 Byte, Default Value: 4
SettingDescription
0 – 127 | Turn Off Light Time |
---|
Parameter 10: Auto Report Battery Time
The interval time for auto report the battery level. 0 means turn off auto
report battery.The default value is 12. The tick time can setting by the
configuration No.20.
Size: 1 Byte, Default Value: 12
SettingDescription
0 – 127 | Auto Report Battery Time |
---|
Parameter 11: Auto Report Door/Window State Time
The interval time for auto report the door/window state. 0 means turn off
auto report door/window state. The default value is 12. The tick time can
setting by the configuration No.20.
Size: 1 Byte, Default Value: 12
SettingDescription
0 – 127 | Auto Report Door/Window State Time |
---|
Parameter 12: Auto Report Illumination Time
The interval time for auto report the illumination. 0 means turn off auto
report illumination.The default value is 12. The tick time can setting by the
configuration No.20.
Size: 1 Byte, Default Value: 12
SettingDescription
0 – 127 | Auto Report Illumination Time |
---|
Parameter 13: Auto Report Temperature Time
The interval time for auto report the temperature. 0 means turn off auto
report temperature.The default value is 12. The tick time can setting by the
configuration No.20.
Size: 1 Byte, Default Value: 12
SettingDescription
0 – 127 | Auto Report Temperature Time |
---|
Parameter 20: Auto Report Tick Interval
The interval time for auto report each tick. Setting this configuration will
effect configuration No.10, No.11, No.12 and No.13.Caution: Setting to 0 means
turn off all auto report function.
Size: 1 Byte, Default Value: 30
SettingDescription
0 – 255 | Auto Report Tick Interval |
---|
Parameter 21: Temperature Differential Report
The temperature differential to report.0 means turn off this function. The
unit is Fahrenheit.Enable this function the device will detect every minutes.
And when the temperature is over 140 degree Fahrenheit, it will continue
report.Enable this functionality will cause some issue please see the detail
in the u201cTemperature Reportu201d section.
Size: 1 Byte, Default Value: 1
SettingDescription
0 – 127 | Temperature Differential Report |
---|
Parameter 22: Illumination Differential Report
The illumination differential to report.0 means turn off this function. The
unit is percentage.Enable this function the device will detect every minutes.
Enable this functionality will cause some issue please see the detail in the
Illumination Report section.
Size: 1 Byte, Default Value: 0
SettingDescription
0 – 99 | Illumination Differential Report |
---|
Technical Data
Dimensions | 95x28x35 mm |
---|---|
Weight | 48 gr |
Hardware Platform | ZM5202 |
EAN | 4713698570187 |
IP Class | IP 20 |
Battery Type | 1 * CR123A |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-14080018 |
Z-Wave Product Id | 0x013C.0x0002.0x000E |
Frequency | Europe – 868,4 Mhz |
Maximum transmission power | 5 mW |
Supported Command Classes
- Association
- Association Group Information
- Battery
- Sensor Binary
- Configuration
- Device Reset Locally
- Firmware Update Md
- Manufacturer Specific
- Multi Command
- Sensor Multilevel
- Notification
- Powerlevel
- Security
- Version
- Wake Up
- Zwaveplus Info
Controlled Command Classes
- Basic
Explanation of Z-Wave specific terms
-
Controller — is a Z-Wave device with capabilities to manage the network.
Controllers are typically Gateways,Remote Controls or battery operated wall controllers. -
Slave — is a Z-Wave device without capabilities to manage the network.
Slaves can be sensors, actuators and even remote controls. -
Primary Controller — is the central organizer of the network. It must be
a controller. There can be only one primary controller in a Z-Wave network. -
Inclusion — is the process of adding new Z-Wave devices into a network.
-
Exclusion — is the process of removing Z-Wave devices from the network.
-
Association — is a control relationship between a controlling device and
a controlled device. -
Wakeup Notification — is a special wireless message issued by a Z-Wave
device to announces that is able to communicate. -
Node Information Frame — is a special wireless message issued by a
Z-Wave device to announce its capabilities and functions.
Read User Manual Online (PDF format)