HUUM CLIFF 9.0STU Pkg 9.0kW Sauna Heater Installation Guide
- June 8, 2024
- HUUM
Table of Contents
HUUM CLIFF 9.0STU Pkg 9.0kW Sauna Heater
THINGS TO CHECK BEFORE INSTALLATION
- Does the output (kW) match the volume (m³) of the sauna room?See Table 1.
- In case there are any uninsulated brick, tile or glass walls in the sauna room, an additional volume of 1,5 m³ should be added to the sauna room for each such square meter of the wall.
- The suitable output of the heater will be determined based on Table 1.
- The producer’s warranty guarantee is invalid if the heater and sauna room have been dimensioned incorrectly!
- Minimal safe distances between the sauna room’s ceiling and walls in view of installing the electric heater are listed in Table 1.
- CLIFF Mini 3,5 is attached to the wall with a special bracket See CLIFF Mini 3,5 heater data in the table below.
Table 1
| Output
kW
| Room
m3
| Weight
kg
| A
mm
| B
mm
| H
mm
| Width/ Depth mm| Fuse
A
| Power cable
N × mm2
---|---|---|---|---|---|---|---|---|---
CLIFF
Mini 3,5
| 3,5| 3,5-6| 15| 60| 390| 975| 270/160| 10| 3 × 2,5
CLIFF 6| 6| 5–10| 16| 60| 390| 975| 270/270| 10| 5 × 2,5
CLIFF 9| 9| 9–15| 16| 120| 510| 975| 270/270| 16| 5 × 2,5
CLIFF 10,5| 10,5| 10-17| 17| 120| 510| 975| 270/270| 16| 5 × 2,5
INSTALLATION
Positioning the heater
- The heater must be positioned in such a way that there is a safe distance between flammable materials and the external surfaces of the heater. See Figure.
- In installing the heater, it must be prevented people could have physical contact with the heater or other dangerous situations could emerge during the heating process.
- CLIFF Mini holds approximately 60 kg of stones and CLIFF holds approximately 75 kg.
- The input of the power cable is located on the bottom cover of the heater.
Connecting the heater to the power supply
- Only a certified electrician is allowed to connect the heater to the power supply.
- A rubber-insulated SIHF-JB cable or an equivalent cable must be used as the connection cable.
- It is recommended to connect the unit to the mains without an earth-leakage circuit breaker.
- The maximum current intensity in the cross-sectional area of the cable and circuit breaker is listed in Table 1.