Mounting Instructions
-
Find a clear area in which you can work.
-
Unpack fixture and glass from carton.
-
Carefully review instructions prior to assembly.
-
To begin installation of your fixture it will first be necessary to remove the mounting plate (A) from the canopy (B). This is accomplished by removing the 2 screws (C) at the top and bottom see Drawing 1.
-
Now take mounting plate (A) and attach it to the junction box (J) using two 8-32 screws, Not Provided.
NOTE: make sure the tabs (T) on mounting plate (A) are vertical and plumb when attaching the mounting plate -
Next make all wiring connections following the appropriate instructions on instruction sheet (1S-18) provided.
-
After all wiring connections are completed stuff wires into junction box and slip backplate (B) over mounting tabs on mounting plate (A). Align holes (H) in canopy (B) with threaded holes in tabs (T) and thread in screws (C) removed earlier.
GLASS INSTALLATION
Insert glass (G) over socket cup (B) and turn glas clockwise to lock into place
wiring grounding instructions
SAFETY WARNI NG: READ WIRIN G AND GROUNDING INSTRUCTIO NS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS
wiring instructions
Indoor Fixtures
- Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Dra w ings 1 or 2.
- Connect negative supply wire () (typically white or ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
- Please refer to the grounding instructions below to complete all electrical connections
Outdoor Fixtures
-
Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (3) with appropriately sized twist on connector – see Drawings 2 or 3.
-
Connec t negative supply wire (C) (typically white or the ribbed, marked Side of the two-conductor cord) to negative fixture lead (D).
-
Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and an fixture mounting platform especially. -
Please refer to the grounding instructions below to complete all electrical connections.
grounding instructions
-
Flush Mount Fixtures
For positive ground ing in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture
mounting strap (M) with the ground screw (S) see Draw in g 1.
Note: On straps for screw-supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw. -
Chain Hung Fixtures
Loop fixture ground wire (E)) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M)
and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on
connectors – see Draw in g 2. -
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector
inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.