CODE | 9040063 |
---|---|
MODEL | AI-400 |
Outputs |
Frequency range
| Band| VHF| UHF
MHz| 47 -318| 470 – 862
Gain| dB| 20 ±1,0| 28 ±2,0
Gain adjustment| dB V| 16| 12
Output level| dB V| 102 DIN 45004B 99 (IMD3 -60 dB) 86 (IMD2 -60 dB)
Output level| dB V| 86 CTB
81 CSO
82 XMOD
Noise figure| dB| 4,2 ±0,2| 3,3 ±0,3
Return loss
| dB| 10
Mains voltage| V| 230±10%(1) 50/60 Hz
VA| 6
Operating temperature| o C| -10..+65
Protection index
| | IP 20
Data published in compliance with the detinitions and measurement methods of the following standards: EN 50083-3, EN 50083-4 and EN 50083-5
CODE | 9040060 | 9040061 |
---|---|---|
MODEL | CA-210 | CA-215 |
Outputs | 2 | |
Frequency range | Band | VHF |
MHz | 40-400 | 470 – 862 |
Gain | dB | 24 ±2,0 |
Gain adjustment | dB V | 16 |
Output level | dB V | 102 DIN 45004B 99 (IMD3 -60 dB) 86 (IMD2 -60 dB) |
Output level | dB V | 86 CTB |
80 CSO
89 XMOD
Noise figure| dB| <4,5| <3,0| <4,5| <3,0
Return loss
| dB| 10
Output voltage| V| 24| 12
mA| 55| 60
Mains voltage| V| 230±10%(1) 50/60 Hz
VA| 20
Operating temperature| o C| -5..+60
Protection index
| | IP 20
CODE| 9040051| 9040052
---|---|---
MODEL| AI-221| AI-223
Outputs| | 2
Frequency range| Band| RETURN| VHF/UHF| RETURN| VHF/UHF
MHz| 0-30| 47- 862| 0-65| 86- 862
Gain| dB| -5,5 ±1,0| 25 ±2,0| -4,5 ±1,0| 25 ±2,0
Gain adjustment| MHz| –| 47| 862| –| 86| 862
dB| –| 20| 10| –| 15| 10
Output level| dB V| | 105
102
90
| DIN 45004B
(IMD3 -60 dB)
(IMD2 -60 dB)
| |
Output level| dB V| | 89
84
90
| CTB CSO XMOD| |
Noise figure| dB| 6
Return loss
| dB| 10
Mains voltage| V| | 230±10%(1)| 50/60 Hz| |
VA| 5,5
Operating temperature| o C| -5..+60
Protection index
| | IP 20
HOW TO FIX THE AMPLIFIER
INDIVIDUAL INSTALLATION
INSTALLATION INSIDE THE APARTMENT
CATV INSTALLATION
COLLECTIVE INSTALLATION WITH S CHANNELS
Safety Instructions
- Do not place the equipment where water can drip or splash onto it.
- Do not place objects containing liquid, such as glasses, on the equipment.
- Do not place sources of naked flame, such as burning candles, on the equipment.
- Do not block the ventilation slots of the equipment with objects such as newspapers, curtains, etc.
- When installing the equipment, leave some free space around it to provide adequate ventilation.
- Install the equipment in such a way that the mains supply plug or the connector of the equipment can be easily reached
ALCAD Electronics, S.L.
Pol. Ind. Arreche-Ugalde, 1
Apdo. 455 | 20305 IRUN – Spain
Tel. (+34) 943 63 96 60
info@alcad.net