ALCAD 904 Series Indoor Multiband Amplifier User Guide

June 8, 2024
ALCAD

ALCAD 904 Series Indoor Multiband Amplifier

CODE 9040063
MODEL AI-400
Outputs  

Frequency range

| Band| VHF| UHF
MHz| 47 -318| 470 – 862
Gain| dB| 20 ±1,0| 28 ±2,0
Gain adjustment| dB V| 16| 12
Output level| dB V| 102 DIN 45004B 99 (IMD3 -60 dB) 86 (IMD2 -60 dB)
Output level| dB V| 86 CTB

81    CSO

82    XMOD

Noise figure| dB| 4,2 ±0,2| 3,3 ±0,3
Return loss

| dB|  10
Mains voltage| V| 230±10%(1) 50/60 Hz
VA| 6
Operating temperature| o C| -10..+65
Protection index

|  | IP 20

Data published in compliance with the detinitions and measurement methods of the following standards: EN 50083-3, EN 50083-4 and EN 50083-5

CODE 9040060 9040061
MODEL CA-210 CA-215
Outputs   2
Frequency range Band VHF
MHz 40-400 470 – 862
Gain dB 24 ±2,0
Gain adjustment dB V 16
Output level dB V 102 DIN 45004B 99 (IMD3 -60 dB) 86 (IMD2 -60 dB)
Output level dB V 86 CTB

80 CSO

89 XMOD

Noise figure| dB| <4,5| <3,0| <4,5| <3,0
Return loss

| dB|  10
Output voltage| V| 24| 12
mA| 55| 60
Mains voltage| V| 230±10%(1) 50/60 Hz
VA| 20
Operating temperature| o C| -5..+60
Protection index

|  | IP 20
CODE| 9040051| 9040052
---|---|---
MODEL| AI-221| AI-223
Outputs|  | 2
Frequency range| Band| RETURN| VHF/UHF| RETURN| VHF/UHF
MHz| 0-30| 47- 862| 0-65| 86- 862
Gain| dB| -5,5 ±1,0| 25 ±2,0| -4,5 ±1,0| 25 ±2,0
Gain adjustment| MHz| –| 47| 862| –| 86| 862
dB| –| 20| 10| –| 15| 10
Output level| dB V|  | 105

102

90

| DIN 45004B

(IMD3 -60 dB)

(IMD2 -60 dB)

|  |
Output level| dB V|  | 89

84

90

| CTB CSO XMOD|  |
Noise figure| dB|  6
Return loss

| dB|  10
Mains voltage| V|  | 230±10%(1)| 50/60 Hz|  |
VA| 5,5
Operating temperature| o C| -5..+60
Protection index

|  | IP 20

HOW TO FIX THE AMPLIFIER

ALCAD 904 Series Indoor Multiband Amplifier-FIG2

INDIVIDUAL INSTALLATION

ALCAD 904 Series Indoor Multiband Amplifier-FIG3

INSTALLATION INSIDE THE APARTMENT

CATV INSTALLATION

ALCAD 904 Series Indoor Multiband Amplifier-FIG6

COLLECTIVE INSTALLATION WITH S CHANNELS

ALCAD 904 Series Indoor Multiband Amplifier-FIG7

Safety Instructions

  • Do not place the equipment where water can drip or splash onto it.
  • Do not place objects containing liquid, such as glasses, on the equipment.
  • Do not place sources of naked flame, such as burning candles, on the equipment.
  • Do not block the ventilation slots of the equipment with objects such as newspapers, curtains, etc.
  • When installing the equipment, leave some free space around it to provide adequate ventilation.
  • Install the equipment in such a way that the mains supply plug or the connector of the equipment can be easily reached

www.alcadelectronics.com

ALCAD Electronics, S.L.
Pol. Ind. Arreche-Ugalde, 1
Apdo. 455 | 20305 IRUN – Spain
Tel. (+34) 943 63 96 60
[email protected]

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ALCAD User Manuals

Related Manuals