aico Ei407 Manual Call Point User Manual

June 8, 2024
aico

aico Ei407 Manual Call Point

aico-Ei407-Manual-Call-Point-product-image

Contains vital information on the product’s operation and installation.
Read and retain carefully. If you are just installing this product the manual MUST be given to the householder.

INTRODUCTION

Pressing on the Ei407 Manual Call Point (Manual Call Point) black spot causes all Alarms on RF Bases and RF Alarms to sound. This informs the occupants that the building must be evacuated.
The Ei407 Manual Call Point also provides a means to test the Alarms without having to reach up to the Alarms on the ceilings, as it can be reset with the plastic key (supplied).
We suggest that the plastic key is mounted on a small nail under or alongside the Manual Call Point for future use when resetting (as shown above).

INSTALLATION

It is recommended that you install all the other RF Bases / Alarms and any other RF components before installing this Manual Call Point.
All RF units should be located in their final positions before House Coding commences.

  1. The Manual Call Point should be positioned (approx) 1.2 meters high on a wall, in a suitable location on an exit route (avoid locating near metal objects).

  2. Securely attach the mounting box to the wall using the fixing screws supplied.

  3. Remove the bottom housing by first pushing in the forked end of the key (with arrow side out) into the two slots (see Figure 1). The bottom housing should drop down by about 10mm and expose the yellow edge on the top of the white element (with the black spot). Remove the key, pull the bottom housing down and then lift it up to remove (see Figure 2).

  4. Next remove the white element by lifting the lower edge (see Figure 3).

  5. Connect the built-in battery by sliding the battery switch into the “on” position.(see Figure 4).

  6. Press the House Code switch until the light on the front turns on red (see Figure 4) (The unit will now send out a coded alarm signal and the red light will flash).

  7. Screw the front plate to the wall box using the two machine screws provided (see Figure 5).

  8. Now re-install the white element, yellow edge uppermost (see Figure 6). Replace the bottom housing by lining up the two notches and carefully pushing it flat – this should leave it about 10mm below the bottom edge.
    Now slide the bottom housing upwards (see Figure 7). This resets the switch. The yellow edge on the white element should now be hidden (The unit will now send out a coded alarm cancel signal). The red light will then continue to flash to show it is in House Code mode, for the next 15 minutes.

  9. Immediately put all other RF Smoke Alarms and other components into House Code mode within 10 minutes.

  10. In House Code mode, the Manual Call Point will now send a radio message every 5 seconds. All RF Bases and Smoke/Heat Alarms within range that are also in House Code mode themselves will memorise the House Code of the Manual Call Point.

  11. Check that the number of amber light flashes (for RF Bases) or blue light flashes (for RF Smoke Alarms) corresponds with the number of units in the system (e.g. Bases / Alarms plus Manual Call Point). For example, with 3 RF Bases and 1 Manual Call Point you should see 4 amber light flashes from each Base.
    (Note: the Manual Call Point flashing red light does not indicate the number of units in the system. It just flashes rapidly to show it is in House Code mode. The Manual Call Point is only an RF transmitter and does not receive any RF signals).

  12. Remove all the RF Bases / Alarms from House Code mode as described in their instruction leaflets.

  13. The Manual Call Point will exit the House Code mode by itself after approx. 15 minutes without further user intervention.
    However, this could result in problems with nearby systems if their units are being House Coded at the same time. If this is the case remove the Manual Call Point from its mounting box and then from House Code mode by pressing and holding the code button until the red light comes on (i.e. use the same method as to enter House Code mode). Release the button and the red light will go out, indicating that the Manual Call Point has exited House Code mode. Re- assemble and attach to box as described previously.

Please note that this will cause the Manual Call Point to send out a coded alarm signal which will activate the RF Bases / Alarms that have previously been House Coded during the installation procedure.

CHECKING & TESTING THE MANUAL CALL POINT

The Manual Call Point is an important alarm device and should be tested after installation and then monthly (and after prolonged absence) to ensure correct operation as follows.

  • Check that the light on the front flashes green every 40 seconds. This indicates it has power.
  • Press the black spot and the white element will drop down exposing the yellow edge to show it is activated. The light will turn red and stay on continuously for 3 seconds and then continue to flash red (every 45 seconds) for 5 minutes indicating transmission of the alarm signal (Note: after 5 minutes the RF alarm signal ceases and therefore the smoke alarms will stop alarming. This prevents the batteries in the Manual Call Point and the alarm from being depleted).
  • Check the RF units are now in alarm (If some or all of the alarms have not been activated, then the House Coding procedure should be repeated. If there are still some problems, see the “Troubleshooting RF” section on page 4).
  • The Manual Call Point should be reset with the plastic key provided by pushing the forked end (arrow side up) into the slots (see Figure
  1. and pulling the bottom housing down. Remove the plastic key. Now push the bottom housing firmly against the back and slide upwards. This resets the switch. The yellow strip on the white element should now be hidden.
  • If the Manual Call Point is not reset the light will flash red every 40 seconds to remind the user to reset it.

On reset, the alarm cancel signal will be transmitted (indicated by a single red light flash for 3 seconds). If the light flashes amber every 9 seconds this indicates that the batteries are depleted and the Manual Call Point will no longer be able to send an alarm signal. The unit must be removed from its location and returned for repair if within the guarantee period, (see sections 7 & 8 for details).
If the end of life has been reached dispose according to local guidelines and regulations (see section 6 “End of Life”).

TROUBLESHOOTING RF

If, when checking the radio interconnection, some of the alarms do not respond to the Manual Call Point test, then:

  • Ensure the Manual Call Point has been activated correctly, the yellow edge is visible, and the light has come on red continuously for 3 seconds and then continues to flash red every 45 seconds.
  • Rotate/relocate the other problematical RF units. There are a number of reasons why the radio signals may not reach all the Alarms in your system (see section 5 on “Limitations of Radio Communications”). Try rotating the units or relocating the units (e.g. move them away from metal surfaces or wiring) as this can significantly improve signal reception.

Rotating and/or relocating the units may move them out of the range of existing units even though they may have already been House Coded correctly in the system. It is important therefore to check that all units are communicating in their final installed positions. If units are rotated and/or resited, we recommend that all units are returned to the factory settings (see their respective use and care instructions). Then House Code all units again in their final positions. The radio interconnection should then be re-checked again.

Clearing the House Codes:
It may be necessary at some stage to clear the House Codes (e.g. if you wanted to use the Manual Call Point with different Smoke Alarms).

To clear the House Codes:

  • Remove the Manual Call Point from the mounting box.
  • Slide the battery switch off. Wait 5 seconds and then slide switch back on.
  • Press and hold the House Code button for approx 6 seconds, until the red light turns on, then flashes slowly. Release the button and the red light will go out.
  • Re-attach the Manual Call Point to the mounting box.

Note clearing the House Codes will now reset the Manual Call Point to the original factory settings. It will now only communicate with un-coded alarms (see Bases / Alarm instruction leaflet for information on how to un-code the Bases / Alarms).

LIMITATIONS OF RADIO COMMUNICATIONS

Ei Electronics radio communication systems are very reliable and are tested to high standards. However, due to their low transmitting power and limited range (required by regulatory bodies) there are some limitations to be considered:

  • Radio equipment, such as the Manual Call Point, should be tested regularly – at least monthly. This is to determine whether there are sources of interference preventing communication. The radio paths may be disrupted by moving furniture or renovations, and so regular testing can highlight these and other faults.
  • Receivers may be blocked by radio signals occurring on or near their operating frequencies, regardless of the House Coding.

END OF LIFE

The Manual Call Point is designed to last 10 years in normal use. However the Manual Call Point must be replaced if:

  1. The light does not flash green every 40 seconds.
  2. The unit is over 10 years old (see “replace by” label on the side of the mounting box).
  3. If pressing the black spot fails to operate the Smoke Alarms.
  4. If the amber light is flashing every 9 seconds (indicating the battery is depleted). (Excess use of the Manual Call Point can shorten battery life).

GETTING YOUR EI407 MANUAL CALL POINT SERVICED

If your Manual Call Point fails to work after you have read this leaflet, contact Customer Assistance at the nearest address given at the end of this leaflet. If it needs to be returned for repair or replacement put it in a padded box with the battery disconnected (slide switch to
‘off’ position – see Figure 4). Send it to “Customer Assistance and Information” at the nearest address given on the Manual Call Point or in this leaflet. State the nature of the fault, where the Manual Call Point was purchased and the date of purchase.
Note: It may be necessary, sometimes, to return a Smoke Alarm (see Smoke Alarm instruction leaflet) along with the Manual Call Point, if you cannot establish which is faulty.

FIVE YEAR GUARANTEE (Limited)

Ei Electronics guarantees this product against any defects that are due to faulty material or workmanship for a five year period after the original date of purchase. This guarantee only applies to normal conditions of use and service, and does not include damage resulting from accident, neglect, misuse unauthorized dismantling or contamination howsoever caused. Excessive use of the Manual Call Point alarm button will shorten the battery life and is not covered. If this product has become defective it must be returned to one of the addresses below (see “Getting Your Ei407 Manual Call Point Serviced”) with proof of purchase. If the product has become defective during the five year guarantee, the unit will be repaired or replaced without charge. This guarantee excludes incidental and consequential damages.
Do not interfere with the product or attempt to tamper with it. This will invalidate the guarantee.

TECHNICAL SPECIFICATIONS

  • We recommend , for ease of installation and RF communication, that up to 12 RF devices can be installed in any one RF coded system. Please contact us for further advice if additional RF devices are required.
    The crossed out wheelie bin symbol that is on your product indicates that this product should not be disposed of via the normal household waste stream. Proper disposal will prevent possible harm to the environment or to human health. When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner. For more details on collection and proper disposal, please contact your local government office or the retailer where you purchased this product.
    Hereby, Ei Electronics declares that this Ei407 RadioLINK Manual Call Point is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU. The Declaration of Conformity may be consulted at www.eielectronics.com/compliance
    Hereby, Ei Electronics declares that this Ei407 RadioLINK Manual Call Point is in compliance with the essential requirements of the Radio Equipment Regulations 2017. The Declaration of Conformity may be consulted at www.eielectronics.com/compliance

Aico Ltd
Maesbury Rd, Oswestry, Shropshire SY10 8NR, U.K.
Tel: 01691 664100
www.aico.co.uk
Ei Electronics
Shannon, V14 H020, Co. Clare, Ireland. Tel:+353 (0)61 471277
www.eielectronics.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

aico User Manuals

Related Manuals