ACME Stage Par 100 Colour IP User Manual

June 8, 2024
acme

STAGE PAR 100 COLOUR IP

ACME Stage Par 100 Colour IP- User Manual

Please read the instruction carefully before use

Safety Instructions

WARNING

Please read the instruction carefully which includes important information about the installation, usage and maintenance.

  • Please keep this User Manual for future consultation. If you sell the fixture to another user, be sure that they also receive this instruction booklet.
  • Please unpack and check carefully there is no transportation damage before using the fixture.
  • Please disconnect main power before servicing and maintenance.
  • The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent surfaces. Be sure that no ventilation slots are blocked.
  • The maximum ambient temperature is Ta: 40 ℃. DO NOT operate it where the temperature is higher than this.
  • DO NOT connect the device to any dimmer pack.
  • The housing must be replaced if they are visibly damaged.
  • Unit surface temperature may reach up to 60℃. Don’t touch the housing bare-hand during its operation. Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving.
  • Stop using the fixture immediately and disconnect the power source for inspection if the fixture fails. Do not repair it by yourself if you are non-professional technician. For any help, please contact your nearest authorized sales or technical center.

Technical Specifications

  • 4/6/7/8 channel Mode;

  • Dimmer, Strobe;

  • Ideal for Professional stages, Concerts, clubs, discotheques, Mobile DJs, etc.

  • Input Voltage: 100-240V~ 50/60Hz

  • Total Power consumption:  110W

  • Beam Angle: 7°/11.5°/16°/20.5°/25°

  • IP Grade: IP X4

  • LED Sources: LED-PAR100 RGBA IP :PUMG-120F4A-ND4P
    LED-PAR100 RGBA IP II:TX-4562RGBA120

  • Dimension/Weight: 534 x 281 x 224mm, 4.5Kg 21″x11″x8.8″in, 9.9lbs

Installation and Connection

The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture. The equipment must be fixed by professionals. And it must be fixed at a place where is out of the touch of people and has no one pass by or under it. The unit should be mounted in the height of 0 to 30m.

How to set the unit

4.1 Rear Panel

ACME Stage Par 100 Colour IP-fig2

○1 Display: Show the various menus and the selected functions;
○2 LED indicator :

POWER On Power On
DMX On DMX input present

○3 Button :

MENU To select the programming functions
DOWN To go forward in the selected functions
UP To go backward in the selected functions
ENTER To confirm the selected functions

○4 Mains input/output::Use Powercon true one mains connection.
○5 DMX input/output:
For DMX512 link, use 3/5-pin XLR plug cable to input DMX signal, and to link the next unit.
The beam angle can be adjusted manually, which is 7°/1 1.5°/16°/2 0.5°/2 5 °.

ACME Stage Par 100 Colour IP-fig3

4.2 Main Function

To select any functions, press MENU button until the required one is shown on the display. Select the function by ENTER button. Use DOWN and UP button to change the mode. Once the required mode has been selected, press ENTER button to setup or it will return to the main functions without any change after idling 8 seconds automatically. Back to the functions without any change press MENU button. The main functions are shown below:

ACME Stage Par 100 Colour IP-fig4

DMX 512 Address Setting
Select the , press the ENTER button and the display will blink. Use the DOWN and UP button to change the DMX 512 address(001-512 ). Once the address has been selected, press the ENTER button to setup or exit menu mode without any change after 8 seconds automatically. Back to the previous functions without any change press the MENU button.
Channel Mode
Select the , press the ENTER button. Use the DOWN and UP button to select the channel mode (4CH/ 6CH/7CH/8CH). Once the address has been selected, press the ENTER button to setup or exit menu mode without any change after 8 seconds automatically. Back to the previous functions without any change press the MENU button.
Dimmer Mode
Select the , press the ENTER button. Use the DOWN and UP button to select (Dimmer Mode 1)… (Dimmer Mode 4). Once selected, press the ENTER button to setup or exit menu mode without any change after 8 seconds. Back to the functions without any change press the MENU button again.

ACME Stage Par 100 Colour IP-fig5

Mode 1(Optically Linear): The increase in light intensity appears to be linear as DMX value is increased. Mode 2(Square Law): Light intensity control is finer at low levels and coarser at high levels. Mode 3(Inverse Square Law): Light intensity control is coarser at low levels and finger at high levels. Mode 4(S-cure): Light intensity control is finger at low levels and high levels and coarser at medium levels.

Dimmer Speed
Select the , press the ENTER button. Use the DOWN and UP button to select (Fast) or (Smooth). Once selected, press the ENTER button to setup or exit menu mode without any change after 8 seconds. Back to the functions without any change press the MENU button again.
DMX State
Select the , press the ENTER button. Use the DOWN and UP button to select (Blackout) or (Hold the last state) . Once selected, press the ENTER button to setup or exit menu mode without any change after 8 seconds. Back to the functions without any change press the MENU button again.
Display Inverse
Select the , press the ENTER button. Use the DOWN and UP button to select (Display Normal) or (Display Inverse). Once selected, press the ENTER button to setup or exit menu mode without any change after 8 seconds automatically. Back to the functions without any change press the MENU button again.
White Balance
Select the , press the ENTER button. use the DOWN and UP button to select  , You can choose values between 125-255,and press the ENTER button to setup or automatically exit menu mode without any change after 8 seconds. To go back to the functions without any change press the MENU button
Manual mode
Select the , press the ENTER button. Use the DOWN and UP button to select RED(R000-R255)/ GREEN(G000-G255)/ BLUE(B000-B255)/ AMBER(A000-A255)/ the brightness (d000-d255)or strobe(S000-S255). Once selected, press the ENTER button to setup or exit menu mode without any change after 8 seconds automatically. Back to the functions without any change press the MENU button again.

Auto Test
Select the , press the ENTER button and the unit will run self-test by built- in program. To go back to the functions press the MENU button again. Hold and press the  ENU button about one second or wait for one minute to exit the menu mode.
Temperature Display|
Select the , press ENTER button and the display will show the temperature ,To go back to the functions press the MENU button.
Fixture Hour
Select the , press ENTER button and the display will show the number of working hours of the unit. To go back to the functions press the MENU button.
Software Version
Select the , press ENTER button and the display will show the version of software of the unit. To go back to the functions press the MENU button.

RDM function
Select the DMX start menu to change the DMX 512 address(001-512 )
Select the manufac tuner menu to display the lamp brand acme.
Select the device model description menu to select the lamp model STAGE PAR 100 COLOUR IP.
Select the DMX performance menu to set the lamp channel 4channel / 6channel / 7channel / 8channel.
Select the device label menu to change the lamp model. The initial model is STAGE PAR 100 COLOUR IP..
Select the identity device menu, and the off / on option will appear. When you select on, the strobe will appear on the lamp, and select off to turn off the strobe.
Select the device hours menu to display the lamp usage time.
Select the DMX personal menu to display the channel mode used by the luminaire.
Select reset device menu, and the warm / cold option will appear. When warm is selected, the lamp will restart, and exit when cold is selected.
Select the software menu and the lamp program version number will be displayed.
Select the LED menu to display the LED temperature of the lamp.

How to control the unit

  1. By DMX controller;
    No need to turn the unit off when you change the DMX address, as new DMX address setting will be affected at once. Turn on the unit, under the DMX signal , the LED will display the saved channel address (001-512 ).

DMX512 configuration

Channel Mode:

4 Channel Mode

Channel Value Function
1 R 0-255 Dimmer 0→100%
2 G 0-255 Dimmer 0→100%
3 B 0-255 Dimmer 0→100%
4 A 0-255 Dimmer 0→100%

6 Channel Mode

Channel Value Function
1 R 0-255
2 G 0-255
3 B 0-255
4 A 0-255
5 0-255
6 Flash 0-5
6-123 Flash Rate, slow to fast
124-127 Open
128-168 random strobe slow to fast↓
169-208 random strobe
209-249 random strobe
250-255 Open

7 Channel Mode

8 Channel Mode

MX512 Connection

Mode connection:

ACME Stage Par 100 Colour IP-fig6

  1. Connect the fixture together in a “daisy chain” by XLR plug cable from the output of the fixture to the input of the next fixture. The cable cannot be branched or split to a “Y” cable. Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the signal and shut down the system
  2. The DMX output and input connectors are pass-through to maintain the DMX circuit when one of the units’ power is disconnected.
  3. At last fixture, the DMX cable has to be terminated with a terminator to reduce signal errors. Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
  4. Each lighting fixture needs to have an address set to receive the data sent by the controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).
  5. 3/5 pin XLR connectors:.
    3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin 4: Blank, Pin 5: Blank

Troubleshooting

Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting:

A. The fixture does not work, no light

  1. Check the connection of power and main fuse.
  2. Measure the mains voltage on the main conn e ctor.

B. Not responding to DMX controller

  1. DMX LED should be on. If not, check DMX connectors, cables to see if link properly.
  2. If the DMX LED is on and no response to the channel, check the address settings and DMX polarity.
  3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the fixture or the previous one.
  4. Try to use another DMX controller.
  5. Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit.

Error code

Err1| Temperature Fault
Err2| LED Fan Fault
Err3| Main board and sub board communication Fault

Fixture Cleaning

The cleaning of internal must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture’s optics.

  • Clean with soft cloth using normal glass cleaning fluid.
  • Always dry the parts carefully.
  • Clean the external optics at least every 20 days. Clean the internal optics at least every 30/60 days.

Declaration of Conformity
We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the
Electromagnetic Compatibility (EMC) Directive 2004/108/EC.
EN55103-1: 2009 ; EN55103-2: 2009;
EN61000-3-2: 2006 + A1:2009 + A2:2009; EN61000-3-3: 2008.
&
Harmonized Standard
EN 60598-1:2008 + All:2009; EN 60598-2-17:1989 + A2:1991;
EN 62471:2008; EN 62493: 2010
Safety of household and similar electrical appliances
Part 1: General requirements

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals