TECHNOGYM MYWELLNESS KIOSK User Manual
- June 9, 2024
- TECHNOGYM
Table of Contents
- TECHNOGYM MYWELLNESS KIOSK
- Safety warnings
- Description of the product
- Technical characteristics
- Mains connection and switching on
- Lifting and moving the product
- Replacing the fuse
- Manufacturer and product identification
- Technical Service
- Storing and disposing of the product
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TECHNOGYM MYWELLNESS KIOSK
The User Manual was written in the Manufacturer’s original language and then
translated into the language of the country of use. It is an integral part of
the product kit.
Technogym reserves the right to modify its products and documentation at any
time and without notice.
Technogym s.p.a. will accept responsibility for the product only if the following precautions are observed:
- The product is used in compliance with its specifications.
- Every part of the User Manual has been carefully read.
- The place of installation meets the requirements in the User Manual.
- The electrical system conforms to the standards and legal requirements in the country of use.
- Towels or other items are not placed on the product.
Safety warnings
Please read all instructions before using the product. These were written to
ensure the safety of the user and to protect the product.
When using an electrical appliance, basic precautions should be always
followed, including those listed below.
WARNING. To reduce the risk of electric shock, always remove the plug
from the electrical socket immediately after using and before cleaning or
performing any maintenance procedures.
WARNING. To reduce the risk of burns, fire, electric shock or injury to
persons, take the following precautions.
The product should never be left unattended when plugged in. Unplug the
product from the power socket when not in use, before cleaning it, and before
installing or removing electrical parts.
Do not allow children to have unsupervised access to the product.
The product is only to be used for the purpose for it was designed and built,
that is to provide information about the workout sheet, the type of exercises
and the results of the workout. Any other use should be considered incorrect
and therefore dangerous.
Do not use any accessories other than those recommended by Technogym.
Never turn on the product if it has a damaged cable or plug, if it is not
working correctly, if it has been knocked over or damaged, or if it has fallen
into water. In these circumstances, contact the Technogym Technical Support
Service.
Do not pull the product by the power cable or use the cable as a handle.
Keep the power cable away from heated surfaces.
Never drop or insert any object into any opening.
To disconnect the power, move all the controls to the off position then
disconnect the plug from the socket.
Fully assemble the product before using it. Check the product before each use.
Do not continue to use the product if it is not working properly.
Assemble and use the product only on a solid and flat surface.
Keep all the components (such as the power cable and the on/off switch) away
from liquid substances, to avoid all risk of electric shock.
Do not use the product outdoors. Do not leave the product outside exposed to
the elements. Do not expose the product to jets of water.
Keep the product in good working condition. If you see signs of wear, contact
Technogym technical support service.
Do not attempt any maintenance work on the product other than the operations
described in the user manual.
The installation, maintenance and setting operations must be carried out by
qualified Technogym staff or persons authorised by Technogym.
The electrical system must conform to the standards and legal requirements in
the country of use.
Do not place anything on the screen.
Technogym is not responsible for any harm due to any failures or damage caused
by unauthorized maintenance, misuse, accident, negligence, improper assembly
or installation, debris resulting from any construction activities in the area
where the unit is used, rust or corrosion as a result of the product’s
location, alterations or modifications without Technogym written authorization
or for failure on your part to use, operate and maintain the unit as set out
in this User Manual.
Description of the product
- A. 22” full HD touch screen
- B. Technogym key socket
- C. USB port
- D. NFC sensor for the Mywellness band and smartphone
- E. Wireless charger
- F. Network or LAN socket for the Ethernet connection
- G. Socket for the HDMI 1.4 connector (up to 4k)
- H. USB service ports
- K. Microphone input socket. The microphone can be connected with a 6 mm jack, or a 3-pin XLR connector.
- L. Audio stereo output for speakers. RCA connectors
The device is compatible with Bluetooth® 5.0, to connect a microphone and
smartphone.
To view the heart rate of the users, use an ANT+ heart rate monitor and
install WASP-N (North Pole).
Wireless charger
Use a smartphone with Qi certification.
Place the smartphone correctly in the battery charger. The smartphone may not
charge correctly if it is not positioned correctly on the charging surface.
Depending on the position of the wireless battery charger coil, the smartphone
may not charge correctly.
The wireless battery charger is not compatible with quick charge.
Wireless charging may not function correctly if the smartphone has a thick
case. If the case is thick, remove it before placing the smartphone on the
wireless battery charger.
Do not leave the smartphone unmonitored on the battery charger.
Do not place other items between the smartphone and the wireless battery
charger.
Do not leave magnetic cards near the battery charger. Magnetic cards,
including credit cards and boarding cards can be damaged by magnetic fields.
Do not use the battery charger for purposes other than what is intended.
It is recommended to secure the HDMI cable to the appropriate slot with a cable tie.
Technical characteristics
Power supply | 100÷240 Vac 50/60 Hz 2.0 – 1.0A |
---|
Fuse
| 4A – 250V
Littelfuse: 216004; Cooper Bussmann: S501-4-R;
Schurter: 0001.1010, 0034.1522; Bel Fuse: 5HF 4-R, 5SF 4-R
Electric class| I
Risk class| IIa
Protection rating| IP20
Operating temperature| Between +5 and +30°C
Device weight| 24,5 kg
The Mywellness Kiosk is a commercial device intended for residential and professional use indoors.
FCC Regulatory Notices
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- the device may not cause harmful interference; and
- the device must accept any interference received, including interference that may cause undesired operation.
NOTE. Changes or modifications made to this equipment not expressly approved by the manufacturer may void the FCC authorization to operate this equipment.
NOTE. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
ISED Canada Regulatory Notices
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licence-exempt
RSS(s). Operation is subject to the following two conditions:
- the device may not cause harmful interference;
- this device must accept any interference, including interference that may cause undesired operation of the device.
RF Exposure information (SAR)
This equipment complies with FCC and ISED Canada (RSS-102) radiation exposure
limits set forth for extremity SAR and use in contact with it. The highest SAR
value, when tested at a separation distance of 0 mm for extremity use, is 1.52
W/kg against a limit of 4.0 W/kg.
Mains connection and switching on
- M. Main switch. Turns the device power supply voltage on and off.
- N. Fuse. Protects the electrical components of the device.
Before connecting the device to the mains power supply, ensure that the
electrical system specifications comply with current regulations.
Check that the mains voltage corresponds to what is indicated on the product
identification label.
Plug the power cable into the product socket first and then into the wall
socket.
When plugging it in, the switch must be in the 0 position, that is the product
must be off.
If the switch is in the 0 position, the product is off; if the switch is in
the I position, the product is on.
DANGER. The power supply cable plug must be connected to a socket that is properly earthed. If not, an earth connection must be installed by a qualified electrician before connecting the device to the mains electricity. If the product operates poorly or malfunctions, the earth connection reduces the risk of electric shock.
The power supply cable must be positioned such not to create a hazard for
persons.
The wall socket must be located in a place where the unit may be easily
plugged in and unplugged.
Periodically check the condition of the power supply cable.
It is recommended to use a wall socket that is used exclusively for the
product.
Lifting and moving the product
The product has two mono-directional wheels.
To move it, grasp the storage compartment and turn the product towards you
until the wheels are firmly on the ground.
Do not use the screen as a gripping point for movement.
WARNINGS. Move the product very carefully, because it could become
unstable and tip over.
Disconnect all the cables from the sockets before moving the product.
Routine maintenance
Routing maintenance involves correctly cleaning all parts of the machine.
Use non-aggressive solvents. Before pouring liquid detergents, turn off the
product and disconnect the power supply cable from the socket.
The safety of the product is assured only if it is carefully inspected every
two weeks for any signs of damage and/or wear.
Replace defective and worn components immediately, or alternatively remove the
product from service.
Replacing the fuse
DANGER. Turn off the product before replacing the fuse. Turn the switch to 0 and disconnect the power supply plug from the container.
Press the lever to extract the fuse holder (P).
Replace the burnt fuse with the new one that is provided (4A (F) 250V). Refit
the fuse holder in its seat, making sure it snaps incorrectly.
The product is supplied with 2 fuses.
Electrical specifications of the fuse: 4A (F) 250 V
When replacing, only use fuses with the same electrical specifications, an identical value and that are certified. uiyg
Manufacturer and product identification
- A. Manufacturer’s name and address
- B. Manufacturer location
- C. Description of the product
- D. Electrical specifications
- E. Consultation of user manual required
- F. Serial number and date of manufacture
- G. Product model
The values shown in the drawing are indicative. check the label on the product for the correct information.
Technical Service
When you contact the Technogym Technical Support Service, you must give the following information:
- product model (G)
- date of purchase
- serial number (F)
- a precise description of the problem.
Any work on the product by persons unauthorised by Technogym will invalidate the warranty.
https://www.technogym.com/int/contacts/
Tel.: +39 0547 56047
Storing and disposing of the product
If not used for a long period of time, we recommend storing the product:
- in a clean and dry place, covered with a cloth to protect it from dust;
- at a room temperature between -10°C and +70°C and relative humidity between 20% and 90%.
During any long periods when it is not used, disconnect the power supply cable
to turn it off.
Check that the product does not create any type of hazard; do not let children
play with the product.
The product must not be disposed of in the environment, in public areas, or
private areas used for public purposes.
The product is made from recyclable materials such as steel, aluminium and
plastic, which must be disposed of in the manner prescribed by the urban
refuse collection regulations in force, by firms specialised in urban and
environmental hygiene.
Waste deriving from electrical and electronic equipment must not be disposed
of as urban waste. A specific disposal system involving suitable processing,
recovery and recycling in compliance with the regulations in force, is
provided for this kind of waste.
Illegal dumping or improper use of electrical and electronic equipment waste
may cause serious damage to the environment and have repercussions on people’s
health.
Under the provisions put into effect by the European Union Member States,
private citizens resident within the European Community may take used
electrical and electronic equipment to authorised collection centres.
If the product is used for professional purposes, contact your reseller or the
Technogym Customer Service, in the various Countries, to arrange for
collection and disposal of waste from electrical and electronic equipment.
For disposal of electrical and electronic equipment in Countries outside the
European Union, contact your local authorities.
Average life of the device: 10 years.
Disposing of the battery
The product contains a lithium battery. The battery is made of non-recyclable
materials. Do not dispose of the battery in the environment.
The battery must be disposed of in compliance with the local regulations.
Contact firms specialised in urban and environmental hygiene.
Observe the following instructions to remove the battery safely.
-
Remove the cover (A) and the tab (B).
-
Remove the screws (C).
-
Release the cover (D) from its seat.
-
Turn the cover (D) and place it on the storage compartment.
-
Remove the connectors (E).
-
Unscrew the screws (F).
-
Remove the battery (G).
Mywellness Kiosk_en 0SM01173AB
July 2022
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>