SAGITTER HL F4 Fresnel 230W LED User Manual

June 9, 2024
SAGITTER

SAGITTER HL F4 Fresnel 230W LED

SAGITTER-HL-F4-Fresnel-230W-LED

INTRODUCTION

Thank You for choosing one of Our products!
Please refer to the instructions and warnings contained in this user manual, please retain it for future reference.
This manual contains information about the installation and use of the device.
The information contained in this publication has been carefully prepared and checked. However it is not assumed any responsibility for any inaccuracies. All rights are reserved and this document can not be copied, photocopied, reproduced in whole or in part without previous written permission of PROEL. PROEL reserves the right to make, without notice, any aesthetical, functional or design changes or modifications in everyone of its products. PROEL doesn’t assume any responsibility for the use or application of the products here described.
The crossed bin symbol, shown on the product or on accompanying documents, indicates that the product should not be disposed with other household waste at the end of the lifecycle. To avoid any damage to the environment, the user is encouraged to separate this product from other kinds of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Home users are encouraged to contact the retailer where they purchased this product or their local government office for details on separate collection and recycling this type of product. Business users are encouraged to contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial waste.

  • The lightning symbol with arrow in an equilateral triangle intends to alert the user to the presence of not insulated “dangerous voltages” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
  • The exclamation point symbol within an equilateral triangle intends to alert the user to the presence of important instructions for use and maintenance on the accompanying documents of the product.
  • The “F” inside an equilateral reversed triangle means that the product is suitable for mounting on normally flammable surfaces.
  • The product to which this manual refers comply with the European Directives pursuant to the safety of electrical equipment supplied at low voltage (LVD) and to the Electromagnetic Compatibility (EMC)
SAFETY INSTRUCTIONS

Caution! This product is not suitable for household illumination.
Please read this manual before installing and applying power to the equipment, follow the safety precautions listed below and observe all warnings in this manual and printed on. Please contact a PROEL distributor for assistance with any questions about how to activate the equipment safely. Contact a qualified technician for any maintenance work not described in this manual. Do not modify the fixture or install accessories and upgrade kits that are not the Proel original ones.
People involved in the installation and maintenance of the device must:

  • Be qualified
  • Follow the instructions of this manual in the theaters, in the halls, in the places where the events take place, etc.

CHECKS BEFORE INSTALLATION

Make sure all the parts for fixing the product are in good condition.
Make sure that the anchor point is stable before positioning the product.
The safety cable must be properly attached to the device and fixed to the supporting structure so that, in case of failure of the primary supporting system, it has the lowest possible fall of the device. If the safety cable wear, must be replaced with an original spare.

MINIMUM DISTANCE OF ILLUMINATED OBJECTS
The projector must be positioned so that the objects hit by the beam of light are at least 2 meters from the lens of the projector.

MINIMUM DISTANCE FROM FLAMMABLE MATERIALS
The product must be positioned so that any flammable material is at least 0.50 meters from any point of the surface of the device. Never place filters or other materials over the lens or on the optical axis.

MOUNTING SURFACES
The device is suitable for mounting on normally flammable surfaces.

REFERENCE TEMPERATURE
The ambient temperature range of use of the device varies between + 5 ° C (min) and + 40 ° C (max), outside of that range the device should not be used.
The maximum temperature of the housing Tb = 80 ° C must never be exceeded. Do not block the exhaust fans, ensuring a minimum clearance of 0.5 meters around the ventilation holes.

IP20 PROTECTION RATING
The device is protected against the penetration of solid bodies larger than 12 mm (0,47 “) in diameter (first digit 2), but not against dripping water, rain, splashes or jets of water (second digit 0). Use only in dry areas. Inside use only. Do not expose the equipment to rain or moisture.

PROTECTION AGAIN ELECTRIC SHOCK
The device must be connected to a power supply system with efficient earthing. Moreover, it is recommended to protect power supply lines of the product from indirect contact and / or shorting to earth by using appropriately sized anti electrical shock switch.

CONNECTION TO THE MAINS
The electrical connection must be carried out by a qualified electrician.
Ensure that the mains frequency and voltage correspond to those for which the equipment is designed, as shown in the electrical data label. This label also shows the power consumption that is necessary to refer to evaluate the maximum number of devices to be connected to the electricity line, in order to avoid power overloading.
If the external power cord of this light is damaged, it must be replaced with a special cord exclusively available from Your PROEL dealer.
Never operate the equipment with lenses and / or covers missing or damaged. In case of non-use, it is recommended to unplug the projector from the mains.

MAINTENANCE

Before starting any maintenance or cleaning the product, disconnect the power from the mains and disconnect the power cable from the device. After switching off, do not remove any part of the device for at least 35 minutes to avoid the risk of burns. The lenses, if damaged, must be replaced with original spare parts.

WARNING

CAUTION. Do not look directly at the light source. Do not look at the beam with lenses, glasses, mirrors or similar optical instruments that could change the convergence of light, causing serious damage to people and / or things.

WARNING! DANGER FOR THE EYES! Do not look directly at the light source

OPENING AND CONTROL

Carefully open the package, check the content and make sure that all the parts are present and are in good condition. In cases where some parts are not present or are damaged, immediately contact Your supplier and retain the packaging for verification.
WARNING!
If the product has been exposed to drastic temperature changes, let the unit turned off until it reaches room temperature because the presence of condensation can damage the product if it is turned on.

Verify that the box contains the following items:

  • N° 1 SG HLF4 / SG HLF2
  • N° 1 Barndoor
  • N° 1 Power supply cable
  • N° 1 User manual
FRONT VIEW
  1. Lens
  2. Manual dimmer knob
  3. Display + buttons
  4. BracketSAGITTER-HL-F4-Fresnel-230W-LED-1
REAR VIEW
  1. USB connector for software upgrade or wireless antenna (optional)
  2. Fuse
  3. Power IN connector
  4. Power OUT connector (max 8A)
  5. Manual zoom knob
  6. 3/5 poles DMX IN/OUTSAGITTER-HL-F4-Fresnel-230W-LED-2

INSTALLATION AND SWITCH ON

PRODUCT INSTALLATION
Do not shake the device. Avoid the use of too much force during installation or unit fixing. The unit can be installed on the floor resting on the rubber feet, on the wall, ceiling or on a truss.SAGITTER-HL-F4-Fresnel-
230W-LED-3

WARNING! IT’S REQUIRED
the mounting of the safety rope (PLH232 – PLH248) sold separately) in the case where the product is hung on a wall, ceiling or on a truss. Except when the device is placed in the floor, the safety cable is always required.

CONNECTION TO THE MAINSSAGITTER-HL-F4-Fresnel-230W-
LED-5

The device must be connected to a power supply system with a proper earth system. Moreover, it is recommended to protect power supply lines of the products from indirect contact and / or shorting to earth by using appropriately sized anti electrical shock switch. The electrical connection must be carried out by a qualified electrician. Ensure that the mains frequency and voltage correspond to those for which the device is designed, as shown in the electrical data label.

CONNECTION TO THE DMX CHAINSAGITTER-HL-F4-Fresnel-230W-
LED-6

Use a cable conforming to specifications EIA RS-485: pole twisted, shielded, 120Ohm characteristic impedance and low capacity (SAGITTER SG DMX3 – SG DMX5).
Do not use microphone cable or other cable with different characteristics than those specified. Terminations must be made with male / female XLR 3-pin connectors. You must enter on the last device a terminal plug with a 120Ohm resistance (min1 / 4 W) between terminals 2 and 3. IMPORTANT: The cables must not come into contact with each other or with the metal housing of the connectors. The housing itself must be connected to the shield braid and to pin 1 of the connectors.

SETUP

Note: in grey color the default values

Level 1 Level 2 Level 3 Level 4 Comments

DMX SETTINGS

| DMX ADDRESS| 001 – 512|  | Dmx address

DMX CHANNEL MODE

| DIMMER

01CH

|  | 1 channel mode: only

dimmer

DIMMER 16 BIT

02CH

|  | 2 channels mode: dimmer

and dimmer fine

02CH

02CH

|  | 2 channels mode: dimmer

and strobe

STANDARD

04CH

|  | 4 channels mode: see

details

EXTENDED

05CH

|  | 5 channels mode: see

details

NO DMX STATUS| HOLD LAST|  | Last status if DMX lost
BLACK|  | Black out if DMX lost

PERSONALITY

| SLAVE| OFF|  | Slave mode
ON|
DIM MODES| LED|  | LED dimmer mode
HALOGEN|

DIM CURVES

| LINEAR|  |

Dimmer curves

SQUARE|
I-SQUARE|
S-CURVE|

FANS

| AUTO|  |

Fans speed

HIGH|
SILENT|

REFRESH RATE

| 900 Hz|  |

LED refresh rate

1000 Hz|
1100 Hz|
1200 Hz|
1300 Hz|
1400 Hz|
1500 Hz|
2500 Hz|
4000 Hz|
5000 Hz|
10 KHz|
15 KHz|
20 KHz|

DISPLAY

|

SCREEN SAVER DELAY

| 10 s|

Display backlight off

20 s
30 s
40 s
50 s
1 min
2 min
3 min
4 min
5 min
10 min

SCREEN LOCK

| OFF|

Display lock

10 s
20 s
30 s
40 s
50 s
1 min
2 min
3 min
 |  |  | 4 min|
---|---|---|---|---
5 min
10 min
USB UPDATE (1)| NO|  | USB update
YES|

SERVICE (2)

| CALIBRATION| WHITE 000 – 255|

Pwd = 050

FACTORY RESTORE| YES / NO
EDIT RDM UID| XXXXX  XxXXXX

MANUAL CONTROL

| DIMMER| 000 – 255|  | Manual dimmer control

STROBE

|

000 – 255

|  | Manual strobe control (for details see the DMX

table)

INFORMATION

| FIXTURE LIFETIME (3)| Power On Time (3)| xxxxx h (3)|
FIX LAST RUNTIME (4)| PowrOnTimAbleRes (4)| xxxxx h (4)|
PowerOnTimeReset (4)| Pwd = reserved|
TOTAL LAMP HOURS (5)| xxxxx hours (5)|  |

FIXTURE TEMP

|

LEDs

| CURRENT (6)

120F / 49C

|
MAX RESETTABLE (7)

260F / 127C

|
MAX NOT RESETTABLE (8)

260F / 127C

|
LAST MAX TEMP RESET

Passcode = 038

|
DMX VALUES| DIMMER

000

|  | Current DMX values
PRODUCT ID| RDM UID| aaaa-bbbb-cccc (9)|
ERROR LOGS| FIXTURE ERRORS| NONE|
RESET ERROR LOGS| NO / YES|
SOFTWARE VERSION| V1.01A|  |

NOTES:

  1. In order to know how to use this function, please refer to the section USE OF USB CONNECTOR
  2. Inside the function SERVICE it is possible to do following operations:
    • Calibration of the max intensity of the white
    • Reset to default values (in grey color in the table of MENU)
    • Modification of RDM UID. Inside this submenu there are 2 numbers. The number on the right is decimal type and it is possible to modify, the number on the left is hexadecimal type. The modification of this second number is automatic, basing on the modification of the decimal part on the right. It is suggested to avoid modifications on these numbers in order to avoid to lose the tracking of the projector.
  3. Current Power On time. This value automatically resets when the projector is OFF.
  4. Total working time. This value is resettable. It can be useful to reset this value when, for example, the led is replaced, in order to calculate the total lifetime of the new LED.
  5. Total working time. Not resettable
  6. Current temperature
  7. Max temperature resettable with Pwd = 038
  8. Max temperature not resettable
  9. RDM UID it consists of 12 digits: aaaa-bbbb-cccc
    • aaaa: manufacturer ID (1221 = Sagitter)
    • bbbb: series ID (006E = HLF4T/D – 0002 = HLF2T/D))
    • cccc: specific ID of each projector. When the UID is modified in the submenu SERVICE, only these 4 digits are modified.

USE OF THE MANUAL DIMMER CONTROL KNOB

  • Press the knob
  • Rotate until the desired intensity
  • Press again for confirmation

MASTER / SLAVE MODE

  • With the projector still not connected in chain, select the Master projector and set all the slave as SLAVE = ON mode
  • Connect the projectors in chain with XLR cables and the master as first of the chain
  • Adjust the functions of the master with the manual dimmer control knob (after press to confirm) or by using the settings under the submenu MANUAL CONTROL
  • If you want to pass from the Master/Slave chain to a DMX chain, disconnect all the projectors from the chain, set the DMX mode in all the projectors and reconnect them. For more details refer to the note after the DMX tables.
DMX MODE

1-channel mode (Dimmer)

Channel Function Values Description
1 Dimmer 000 – 255 Master dimmer from 0 to 100%

2-channels mode (Dimmer 16 bit)

Channel Function Values Description
1 Dimmer 000 – 255 Master dimmer from 0 to 100%
2 Dimmer fine 000 – 255 Dimmer fine

2-channels mode (02CH)

Channel Function Values Description
1 Dimmer 000 – 255 Master dimmer from 0 to 100%



2

| ****



Strobe

| 000 – 031| Led ON
032 – 063| Led OFF
064 – 095| Strobe from slow to fast
096 – 127| Open
128 – 159| Pulse IN from slow to fast
160 – 191| Open
192 – 223| Random strobe from slow to fast
224 – 255| Open

4-channels mode (Standard)

Channel Function Values Description
1 Dimmer 000 – 255 Master dimmer from 0 to 100%
2 Dimmer fine 000 – 255 Dimmer fine



3

| ****



Strobe

| 000 – 031| Led ON
032 – 063| Led OFF
064 – 095| Strobe from slow to fast
096 – 127| Open
128 – 159| Pulse IN from slow to fast
160 – 191| Open
192 – 223| Random strobe from slow to fast
224 – 255| Open


4

| ****

Dimmer mode

| 000 – 020| LED mode (display bypassed)
021 – 040| Halogen mode (display bypassed)
041 – 255| No function: display priority

5-channels mode (Extended)

Channel Function Values Description
1 Dimmer 000 – 255 Master dimmer from 0 to 100%
2 Dimmer fine 000 – 255 Dimmer fine



3

| ****



Strobe

| 000 – 031| Led ON
032 – 063| Led OFF
064 – 095| Strobe from slow to fast
096 – 127| Open
128 – 159| Pulse IN from slow to fast
160 – 191| Open
192 – 223| Random strobe from slow to fast
224 – 255| Open


4

| ****

Dimmer mode

| 000 – 020| LED mode (display bypassed)
021 – 040| Halogen mode (display bypassed)
041 – 255| No function: display priority











5

| ****









Control (wait 3 seconds after selecting the value)

| 000 – 100| No function
101 – 105| LED refresh rate 900 Hz
106 – 110| LED refresh rate 1000 Hz
111 – 115| LED refresh rate 1100 Hz
116 – 120| LED refresh rate 1200 Hz
121 – 125| LED refresh rate 1300 Hz
126 – 130| LED refresh rate 1400 Hz
131 – 135| LED refresh rate 1500 Hz
136 – 140| LED refresh rate 2500 Hz
141 – 145| LED refresh rate 4000 Hz
146 – 150| LED refresh rate 5000 Hz
151 – 155| LED refresh rate 10000 Hz
156 – 160| LED refresh rate 15000 Hz
161 – 165| LED refresh rate 20000 Hz
166 – 200| No function
201 – 210| Dimmer curve LINEAR
211 – 220| Dimmer curve SQUARE
221 – 230| Dimmer curve INVERSE SQUARE
231 – 240| Dimmer curve S-CURVE
241 – 255| No function

IMPORTANT NOTE: DMX mode has priority over all the functions.
When some projectors are connected in DMX chain and after they are connected to a DMX controller, they automatically pass in DMX mode.
This means that if some of them was set in manual mode, when they will be connected in DMX chain, they automatically pass in DMX mode. If for any reason the DMX controller is switched OFF or the DMX signal is lost, all the projectors of the chain will come back to the previous status and, if in the chain there are different projectors in manual mode, all of them will be connected in manual mode in chain that means different masters in chain.
This is not possible and this could generate strange behaviours and interferences in the chain until the DMX controller will be connected again.
When a DMX chain must be created, all the projectors must be set in DMX mode before the connection, in order to avoid strange situations before described.
If you want that in a DMX chain, when the signal is lost, the projectors must go in a specific condition, it must be used the function NO DMX STATUS under the submenu DMX SETTINGS.

MAINTENANCE

To ensure optimal performance, the unit must be frequently cleaned. Unplug the device from the mains and let it cool for at least 35 minutes to avoid the risk of burns. Use a vacuum cleaner or an air compressor and a soft brush or a lens cloth to remove the dust deposited.
The lenses, like any other damaged part, must be replaced with original spare parts.

TECHNICAL SPECIFICATIONS

  • Power Supply: 100-240V, 50/60HZ

  • LED: 230W (HL F4) – 130W (HL F2)

  • Adjustable Zoom:
    HL F4: da 9° a 51° Beam – da 13° a 62° Field
    HL F2: da 14° a 36° Beam – da 20° a 47° Field

  • Power consumption: 260 W @230 VAC (HL F4) – 150 W @230 VAC (HL F2)

  • Operation Mode: Manual mode, Master/slave, DMX512

  • Electronic Dimming 0-100%

  • DMX 1, 2, 2, 4, 5 Channels

  • Blue LCD graphic display for address and function setting

  • Dimensions (L x H x D):
    HL F4: mm. 357x401x404
    HL F2: mm. 320x380x386

  • Weight: HL F4: kg. 8,7
    HL F2: kg. 7

Contact Us

Sagitter is a brand of PROEL SPA (Worldwide Headquarters) Via alla Ruenia, 37/43

  • 64027 SantOmero (TE) – ITALY
  • Tel.+39 0861 81241
  • Fax +39 0861 887862
  • P.I. 00778590679
  • N.Reg.AEE IT 08020000002762
  • sagitter.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>